Chapter 4 Explanation of Functions<br />

4.2.19 DC braking (DB) setting<br />

The DC braking function allows you to apply DC braking to the<br />

motor according to the load on the motor.<br />

You can control DC braking in two ways: the external control<br />

through signal input to intelligent input terminals and the internal<br />

control to be performed automatically when the motor is started<br />

and stopped.<br />

Note that the motor cannot be stopped by DC braking if the load<br />

on the motor produces a large moment of inertia.<br />

Related code<br />

A051: DC braking enable<br />

A052: DC braking frequency setting<br />

A053: DC braking wait time<br />

A054: DC braking force during deceleration<br />

A055: DC braking time for deceleration<br />

A056: DC braking/edge or level detection for<br />

[DB] input<br />

A057: DC braking force for starting<br />

A058: DC braking time for starting<br />

A059: DC braking carrier frequency setting<br />

C001 to C008: Terminal [1] to [8] functions<br />

Item Function code Data or range of data Description<br />

00 Internal DC braking is disabled.<br />

01 Internal DC braking is enabled.<br />

DC braking enable A051<br />

Internal DC braking is enabled. (The braking<br />

02<br />

operates only with the set braking frequency.)<br />

DC braking<br />

frequency setting<br />

DC braking wait<br />

time<br />

DC braking force<br />

during deceleration/<br />

DC braking force for<br />

starting<br />

DC braking time for<br />

deceleration<br />

DC braking/edge or<br />

level detection for<br />

[DB] input<br />

DC braking time for<br />

starting<br />

A052<br />

A053<br />

A054/A057<br />

A055<br />

A056<br />

A058<br />

DC braking carrier<br />

A059<br />

frequency setting<br />

(NOTE) :applied for 75 to 150kW<br />

0.00 to 60.00 (Hz)<br />

0.0 to 5.0 (s)<br />

0. to 100. (%)<br />

<br />

With internal DC braking enabled, DC braking is<br />

started when the output frequency reaches the<br />

set braking frequency.<br />

The DC braking wait time specifies the delay in<br />

starting DC braking after the set braking time has<br />

elapsed or the DB terminal has been turned on.<br />

"0" specifies the smallest force (zero current);<br />

"100" specifies the largest force (rated current).<br />

0.0 to 60.0 (s)<br />

This setting is valid for the external DC braking in<br />

edge mode or for the internal DC braking.<br />

00 Edge mode (See examples 1-a to 6-a.)<br />

01 Level mode (See examples 1-b to 6-b.)<br />

0.0 to 60.0 (s)<br />

0.5 to 15 (kHz)<br />

<br />

This setting is valid for the internal DC braking.<br />

DC braking is started when the motor-start<br />

command is input.<br />

Unit: kHz<br />

(1) Carrier frequency for DC braking<br />

Use the DC braking carrier frequency setting (A059) to specify the carrier frequency for DC braking.<br />

But the raking power reduced is reduced when 5Hz (up to 55kW) or 3Hz (75-150kW) are set as shown<br />

below. For detailed decreasing ratio, "DC braking limiter" is to be referred.<br />

Maximum<br />

braking<br />

force (%)<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

(75)<br />

(46)<br />

(34)<br />

(22)<br />

(10)<br />

Maximum<br />

braking<br />

force (%)<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

(60)<br />

(40)<br />

(20)<br />

(10)<br />

0<br />

3 5 7 9 1 1 1<br />

DC braking carrier frequency<br />

(kHz)<br />

DC braking force limiter(0.4-55kW)<br />

0<br />

3<br />

4<br />

5<br />

DC braking carrier frequency<br />

(kHz)<br />

DC braking force limiter(75-150kW)<br />

6<br />

7<br />

8<br />

9<br />

1<br />

4 - 20