Chapter 4 Explanation of Functions<br />

(2) Automatic torque boost<br />

When automatic torque boost (data "01") is selected by the torque boost selection (A041/A241), the<br />

inverter automatically adjusts the output frequency and voltage according to the load on the motor.<br />

(During actual operation, the automatic torque boost is usually combined with the manual torque boost.)<br />

When you select the automatic torque boost, adjust the settings of the motor capacity selection<br />

(H003/H203) and motor pole selection (H004/H204) according to the motor to be driven.<br />

If the inverter trips due to overcurrent during motor deceleration, set the AVR function select (A081) to<br />

always enable the AVR function (data "00").<br />

If you cannot obtain the desired operation characteristic by using the automatic torque boost, make the<br />

following adjustments:<br />

Symptom Adjustment method Adjustment item<br />

(1) Increase the voltage setting for manual torque boost<br />

A042/A242<br />

step by step.<br />

Motor torque is insufficient at low<br />

(2) Increase the slippage compensation gain for<br />

speed.<br />

A047/A247<br />

automatic torque boost step by step.<br />

(The motor does not rotate at low<br />

(3) Increase the voltage compensation gain for<br />

speed.)<br />

A046/A246<br />

automatic torque boost step by step.<br />

(4) Reduce the carrier frequency setting. b083<br />

The motor speed falls when a load Increase the slippage compensation gain for the<br />

is applied to the motor.<br />

automatic torque boost step by step.<br />

A047/A247<br />

The motor speed increases when a Reduce the slippage compensation gain for the<br />

load is applied to the motor. automatic torque boost step by step.<br />

A047/A247<br />

(1) Reduce the voltage compensation gain for the<br />

automatic torque boost step by step.<br />

A046/A246<br />

The inverter trips due to overcurrent (2) Reduce the slippage compensation gain for the<br />

when a load is applied to the motor. automatic torque boost step by step.<br />

A047/A247<br />

(3) Reduce the voltage setting for the manual torque<br />

boost step by step.<br />

A042/A242<br />

This function cannot be selection for 3rd moter setting.<br />

<strong>Manual</strong> torque boost valid.<br />