Safety Instructions model cat. cable length(m) carrier frequency(kHz) model cat. cable length(m) carrier frequency(kHz) SJ700-220L C3 5 2.5 SJ700-220H C3 1 2.5 SJ700-300L C3 5 2.5 SJ700-300H C3 1 2.5 SJ700-370L C3 5 2.5 SJ700-370H C3 1 2.5 SJ700-450L C3 5 2.5 SJ700-450H C3 5 2.5 SJ700-550L C3 5 2.5 SJ700-550H C3 5 2.5 SJ700-750H C3 10 2.5 SJ700-900H C3 10 2.5 SJ700-1100H C3 10 2.5 SJ700-1320H SJ700-1500H C3 10 2.5 Table 1 vi
Safety Instructions Precautions Concerning Compliance with UL and CUL Standards (Standards to be met: UL508C and CSA C22.2 No. 14-05) The SJ700 series inverter is an open-type AC inverter with 3-phase input and output, intended for use in an enclosure. The inverter supplies both voltage and frequency, both of which are adjustable, to an AC motor. The inverter can automatically maintain a constant volts/Hz ratio to enhance the motor capability throughout its entire speed range. 1. Only 75C CU or equivalent wires must be used for wiring. 2. Inverter models with the suffix "L" (200 V class models) are suited to circuits that transmit current not exceeding 100k rms symmetrical amperes and with voltage of no more than 240 V. 3. Inverter models with the suffix "H" (400 V class models) are suited to circuits that transmit current not exceeding 100k rms symmetrical amperes and with voltage of no more than 480 V. 4. Suitable for use on a circuit capable of delivering not more than 100 k rms symmetrical amperes, 480 V maximum”. For models with suffix H. 5. “Install device in pollution degree 2 environment”. 6. “Maximum Surrounding Air Temperature 50°C” 7. “CAUTION- Risk of Electric Shock- Capacitor discharge time is at least 10 min.” “Use 75C CU wire only” 8. “Solid state motor overload protection is provided in each model” 9. Tightening torque and wire range for field wiring terminals in the table below: Model No. Required torque (N-m) Wire range (AWG) SJ700-004L 1.8 14(Stranded only) SJ700-007L 1.8 14(Stranded only) SJ700-015L 1.8 14(Stranded only) SJ700-022L 1.8 14(Stranded only) SJ700-037L 1.8 10(Stranded only) SJ700-050L 3.0 8 SJ700-055L 4.0 8 SJ700-075L 4.0 6 SJ700-110L 4.0 6-4 SJ700-150L 4.9 2 SJ700-185L 4.9 1 SJ700-220L 8.8 1 or 1/0 SJ700-300L 8.8 2/0 or Parallel of 1/0 SJ700-370L 20.0 4/0 (Prepared wire only) or Parallel of 1/0 SJ700-450L 20.0 4/0 (Prepared wire only) or Parallel of 1/0 SJ700-550L 19.6 350 kcmil (Prepared wire only) or Parallel of 2/0 (Prepared wire only) vii
- Page 1 and 2: HITACHI INVERTER SJ700-2 SERIES INS
- Page 3 and 4: Safety Instructions Safety Instruct
- Page 5 and 6: Safety Instructions 3. Operation !
- Page 7: Safety Instructions Precautions Con
- Page 11 and 12: Safety Instructions 10. Distributio
- Page 13 and 14: Contents Chapter 1 Overview 1.1 Ins
- Page 15 and 16: Contents 4.2.30 Overload restrictio
- Page 17 and 18: Contents 4.3.15 Speed/position swit
- Page 19: Chapter 1 Overview This chapter des
- Page 22 and 23: Chapter 1 Overview 1.2 Method of In
- Page 24: Chapter 2 Installation and Wiring T
- Page 27 and 28: Chapter 2 Installation and Wiring 2
- Page 29 and 30: Chapter 2 Installation and Wiring 2
- Page 31 and 32: Chapter 2 Installation and Wiring 2
- Page 33 and 34: Chapter 2 Installation and Wiring D
- Page 35 and 36: Chapter 2 Installation and Wiring S
- Page 37 and 38: Chapter 2 Installation and Wiring c
- Page 39 and 40: Chapter 2 Installation and Wiring T
- Page 41 and 42: Chapter 2 Installation and Wiring T
- Page 43 and 44: Chapter 2 Installation and Wiring (
- Page 45 and 46: Chapter 2 Installation and Wiring 7
- Page 47 and 48: Chapter 2 Installation and Wiring (
- Page 49: Chapter 3 Operation This chapter de
- Page 52 and 53: Chapter 3 Operation You can operate
- Page 54 and 55: Chapter 3 Operation 3.2.2 Code disp
- Page 56 and 57: Chapter 3 Operation Key operation a
Safety <strong>Instruction</strong>s<br />
model<br />
cat.<br />
cable<br />
length(m)<br />
carrier<br />
frequency(kHz)<br />
model cat. cable length(m)<br />
carrier<br />
frequency(kHz)<br />
<strong>SJ700</strong>-220L C3 5 2.5 <strong>SJ700</strong>-220H C3 1 2.5<br />
<strong>SJ700</strong>-300L C3 5 2.5 <strong>SJ700</strong>-300H C3 1 2.5<br />
<strong>SJ700</strong>-370L C3 5 2.5 <strong>SJ700</strong>-370H C3 1 2.5<br />
<strong>SJ700</strong>-450L C3 5 2.5 <strong>SJ700</strong>-450H C3 5 2.5<br />
<strong>SJ700</strong>-550L C3 5 2.5 <strong>SJ700</strong>-550H C3 5 2.5<br />
<strong>SJ700</strong>-750H C3 10 2.5<br />
<strong>SJ700</strong>-900H C3 10 2.5<br />
<strong>SJ700</strong>-1100H C3 10 2.5<br />
<strong>SJ700</strong>-1320H<br />
<strong>SJ700</strong>-1500H<br />
C3 10 2.5<br />
Table 1<br />
vi