SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.

SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd. SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.

hitachi.america.us
from hitachi.america.us More from this publisher
29.01.2015 Views

Safety Instructions model cat. cable length(m) carrier frequency(kHz) model cat. cable length(m) carrier frequency(kHz) SJ700-220L C3 5 2.5 SJ700-220H C3 1 2.5 SJ700-300L C3 5 2.5 SJ700-300H C3 1 2.5 SJ700-370L C3 5 2.5 SJ700-370H C3 1 2.5 SJ700-450L C3 5 2.5 SJ700-450H C3 5 2.5 SJ700-550L C3 5 2.5 SJ700-550H C3 5 2.5 SJ700-750H C3 10 2.5 SJ700-900H C3 10 2.5 SJ700-1100H C3 10 2.5 SJ700-1320H SJ700-1500H C3 10 2.5 Table 1 vi

Safety Instructions Precautions Concerning Compliance with UL and CUL Standards (Standards to be met: UL508C and CSA C22.2 No. 14-05) The SJ700 series inverter is an open-type AC inverter with 3-phase input and output, intended for use in an enclosure. The inverter supplies both voltage and frequency, both of which are adjustable, to an AC motor. The inverter can automatically maintain a constant volts/Hz ratio to enhance the motor capability throughout its entire speed range. 1. Only 75C CU or equivalent wires must be used for wiring. 2. Inverter models with the suffix "L" (200 V class models) are suited to circuits that transmit current not exceeding 100k rms symmetrical amperes and with voltage of no more than 240 V. 3. Inverter models with the suffix "H" (400 V class models) are suited to circuits that transmit current not exceeding 100k rms symmetrical amperes and with voltage of no more than 480 V. 4. Suitable for use on a circuit capable of delivering not more than 100 k rms symmetrical amperes, 480 V maximum”. For models with suffix H. 5. “Install device in pollution degree 2 environment”. 6. “Maximum Surrounding Air Temperature 50°C” 7. “CAUTION- Risk of Electric Shock- Capacitor discharge time is at least 10 min.” “Use 75C CU wire only” 8. “Solid state motor overload protection is provided in each model” 9. Tightening torque and wire range for field wiring terminals in the table below: Model No. Required torque (N-m) Wire range (AWG) SJ700-004L 1.8 14(Stranded only) SJ700-007L 1.8 14(Stranded only) SJ700-015L 1.8 14(Stranded only) SJ700-022L 1.8 14(Stranded only) SJ700-037L 1.8 10(Stranded only) SJ700-050L 3.0 8 SJ700-055L 4.0 8 SJ700-075L 4.0 6 SJ700-110L 4.0 6-4 SJ700-150L 4.9 2 SJ700-185L 4.9 1 SJ700-220L 8.8 1 or 1/0 SJ700-300L 8.8 2/0 or Parallel of 1/0 SJ700-370L 20.0 4/0 (Prepared wire only) or Parallel of 1/0 SJ700-450L 20.0 4/0 (Prepared wire only) or Parallel of 1/0 SJ700-550L 19.6 350 kcmil (Prepared wire only) or Parallel of 2/0 (Prepared wire only) vii

Safety <strong>Instruction</strong>s<br />

model<br />

cat.<br />

cable<br />

length(m)<br />

carrier<br />

frequency(kHz)<br />

model cat. cable length(m)<br />

carrier<br />

frequency(kHz)<br />

<strong>SJ700</strong>-220L C3 5 2.5 <strong>SJ700</strong>-220H C3 1 2.5<br />

<strong>SJ700</strong>-300L C3 5 2.5 <strong>SJ700</strong>-300H C3 1 2.5<br />

<strong>SJ700</strong>-370L C3 5 2.5 <strong>SJ700</strong>-370H C3 1 2.5<br />

<strong>SJ700</strong>-450L C3 5 2.5 <strong>SJ700</strong>-450H C3 5 2.5<br />

<strong>SJ700</strong>-550L C3 5 2.5 <strong>SJ700</strong>-550H C3 5 2.5<br />

<strong>SJ700</strong>-750H C3 10 2.5<br />

<strong>SJ700</strong>-900H C3 10 2.5<br />

<strong>SJ700</strong>-1100H C3 10 2.5<br />

<strong>SJ700</strong>-1320H<br />

<strong>SJ700</strong>-1500H<br />

C3 10 2.5<br />

Table 1<br />