Chapter 4 Explanation of Functions<br />

(Example 1) When<br />

the motor operation<br />

is not reversible<br />

(Example 1) When<br />

the motor operation<br />

is reversible<br />

FW<br />

FW<br />

AT<br />

Main frequency<br />

command via the OI<br />

or O terminal<br />

0<br />

fOI<br />

fO<br />

fO2<br />

AT<br />

Main frequency<br />

command via the OI<br />

or O terminal<br />

0<br />

fOI<br />

fO<br />

fO2<br />

Auxiliary<br />

frequency<br />

command via<br />

the O2 terminal<br />

0<br />

Auxiliary<br />

frequency<br />

command via<br />

the O2 terminal<br />

0<br />

fO + fO2<br />

fOI +fO2<br />

fO + fO2<br />

fOI +fO2<br />

Actual frequency<br />

command<br />

0<br />

Forward<br />

operation<br />

Actual frequency<br />

command<br />

0<br />

Forward<br />

operation<br />

Reverse<br />

operation<br />

4.2.12 Frequency operation function<br />

Related code<br />

A141: Operation-target frequency selection 1<br />

The frequency operation function allows you to use the result of an<br />

A142: Operation-target frequency selection 2<br />

arithmetic operation on two frequency commands as the actual A143: Operator selection<br />

frequency command or PID feedback data.<br />

A001: Frequency source setting<br />

A076: PV source setting<br />

To use the operation result as the actual frequency command,<br />

specify "10" for the frequency source setting (A001).<br />

To use the operation result as the PID feedback data, specify "10" for the PV source setting (A076).<br />

Item Function code Data Description<br />

00 Digital operator (A020/A220/A320)<br />

(01)<br />

Control on the digital operator<br />

(Valid only when the OPE-SR is connected)<br />

02 Input via the O terminal<br />

Operation-target frequency<br />

A141/A142 03 Input via the OI terminal<br />

selection 1 and 2<br />

04 Input via the RS485 terminal<br />

05 Input from option board 1<br />

06 Input from option board 2<br />

07 Input of pulse train<br />

00 Addition: (A141) + (A142)<br />

A143<br />

01 Subtraction: (A141) - (A142)<br />

Operator selection for<br />

frequency operation<br />

02 Multiplication: (A141) x (A142)<br />

Frequency source setting A001 10 Output of operation result<br />

PV source setting A076 10 Output of operation result<br />

Note 1: The [1] (up) and [2] (down) keys of the digital operator are ineffective when the frequency<br />

operation function is enabled. Also, the frequency displayed by the output frequency monitoring<br />

(d001), Scaled output frequency monitoring (d007), or output frequency setting (F001) cannot be<br />

changed with key operations.<br />

Note 2: The settings of "A141" and "A142" can be the same.<br />

4 - 13