Chapter 3 Operation<br />

Key operation and transition of the<br />

codes on display<br />

Key operation and transition of the monitored data on display<br />

Pressing the 1 or 2 key respectively scrolls up or down the code displayed in code display mode or<br />

increases or decreases the numerical data displayed in data display mode.<br />

Press the 1 or 2 key until the desired code or numerical data is shown. To scroll codes or<br />

increase/decrease numerical data faster, press and hold the key.<br />

Monitor mode<br />

Pressing the<br />

FUNC<br />

key with a function code displayed shows the<br />

monitored data corresponding to the function code.<br />

FUNC<br />

FUNC<br />

(Monitor display) (*1)<br />

or STR<br />

FUNC<br />

Pressing the<br />

STR<br />

or key with the monitored data displayed reverts<br />

to the display of the function code corresponding to the monitored data.<br />

* With the factory setting, the monitor shows initially after<br />

power-on.<br />

Pressing the<br />

FUNC<br />

key in this status changes the display to .<br />

Function or extended function mode<br />

Pressing the FUNC key with a function code displayed shows the data<br />

corresponding to the function code.<br />

(Data display) (*1)(*2)<br />

Up to the<br />

maximum limit Data setting<br />

Pressing the 1 or 2 key respectively increases or<br />

decreases the displayed numerical data.<br />

(Press the key until the desired data is shown.)<br />

FUNC<br />

FUNC<br />

or<br />

STR<br />

STR<br />

Pressing the key with numerical data displayed<br />

stores the data and then returns to the display of the<br />

corresponding function code.<br />

Note that pressing the FUNC key with numerical data<br />

displayed returns to the display of the function code<br />

corresponding to the numerical data without updating<br />

the data, even if it has been changed on display.<br />

Down to the<br />

minimum limit<br />

*1 The content of the display varies depending on the<br />

parameter type.<br />

*2 To update numerical data, be sure to press the<br />

STR key after changing the data.<br />

3 - 6