Chapter 3 Operation<br />

(1) Example of operation in basic display mode ("b037" = "04" [factory setting])<br />

- Only basic parameters can be displayed in basic display mode. (All parameters in monitor mode,<br />

four parameters in function mode, or 20 parameters in extended function mode)<br />

- Other parameters are not displayed. To display all parameters, select the full display mode ("b037" =<br />

"00").<br />

<br />

No. Display code Item<br />

1 d001 to d104 Monitor display<br />

2 F001 Output frequency setting<br />

3 F002 Acceleration (1) time setting<br />

4 F003 Deceleration (1) time setting<br />

5 F004 Operation direction setting<br />

6 A001 Frequency source setting<br />

7 A002 Run command source setting<br />

8 A003 Base frequency setting<br />

9 A004 Maximum frequency setting<br />

10 A005 [AT] selection<br />

11 A020 Multispeed frequency setting<br />

12 A021 Multispeed 1 setting<br />

13 A022 Multispeed 2 setting<br />

14 A023 Multispeed 3 setting<br />

15 A044 1st control method<br />

16 A045 V/f gain setting<br />

17 A085 Operation mode selection<br />

18 b001 Selection of restart mode<br />

19 b002 Allowable under-voltage power failure time<br />

20 b008 Retry-after-trip selection<br />

21 b011 Retry wait time after trip<br />

22 b037 Function code display restriction<br />

23 b083 Carrier frequency setting<br />

24 b084 Initialization mode selection<br />

25 b130<br />

Selection of overvoltage suppression<br />

function<br />

26 b131 Setting of overvoltage suppression level<br />

27 C021 Setting of intelligent output terminal 11<br />

28 C022 Setting of intelligent output terminal 12<br />

29 C036 Alarm relay active state<br />

Note:<br />

If a desired parameter is not displayed, check<br />

the setting of function "b037" (function code<br />

display restriction). To display all parameters,<br />

specify "00" for "b037".<br />

3 - 5