SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.
SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.
SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chapter 3 Operation<br />
(1) Example of operation in basic display mode ("b037" = "04" [factory setting])<br />
- Only basic parameters can be displayed in basic display mode. (All parameters in monitor mode,<br />
four parameters in function mode, or 20 parameters in extended function mode)<br />
- Other parameters are not displayed. To display all parameters, select the full display mode ("b037" =<br />
"00").<br />
<br />
No. Display code Item<br />
1 d001 to d104 Monitor display<br />
2 F001 Output frequency setting<br />
3 F002 Acceleration (1) time setting<br />
4 F003 Deceleration (1) time setting<br />
5 F004 Operation direction setting<br />
6 A001 Frequency source setting<br />
7 A002 Run command source setting<br />
8 A003 Base frequency setting<br />
9 A004 Maximum frequency setting<br />
10 A005 [AT] selection<br />
11 A020 Multispeed frequency setting<br />
12 A021 Multispeed 1 setting<br />
13 A022 Multispeed 2 setting<br />
14 A023 Multispeed 3 setting<br />
15 A044 1st control method<br />
16 A045 V/f gain setting<br />
17 A085 Operation mode selection<br />
18 b001 Selection of restart mode<br />
19 b002 Allowable under-voltage power failure time<br />
20 b008 Retry-after-trip selection<br />
21 b011 Retry wait time after trip<br />
22 b037 Function code display restriction<br />
23 b083 Carrier frequency setting<br />
24 b084 Initialization mode selection<br />
25 b130<br />
Selection of overvoltage suppression<br />
function<br />
26 b131 Setting of overvoltage suppression level<br />
27 C021 Setting of intelligent output terminal 11<br />
28 C022 Setting of intelligent output terminal 12<br />
29 C036 Alarm relay active state<br />
Note:<br />
If a desired parameter is not displayed, check<br />
the setting of function "b037" (function code<br />
display restriction). To display all parameters,<br />
specify "00" for "b037".<br />
3 - 5