Chapter 3 Operation<br />
3.2.2 Code display system and key operations<br />
This section describes typical examples of digital operator operation (in basic and full display modes) and<br />
an example of special digital operator operation in extended function mode U.<br />
The initial display on the monitor screen after power-on depends on the setting of function "b038". For<br />
details, see Section 4.2.81, "Initial-screen selection," (on page 4-76).<br />
When the setting of function "b038" is "01" (factory setting), the monitor initially shows<br />
as<br />
the setting of function "d001" (output frequency monitoring). Pressing the FUNC key in this status<br />
changes the display to .<br />
Note: The display contents on the monitor depend on the settings of functions "b037" (function code<br />
display restriction), "b038" (initial-screen selection), and "b039" (automatic setting of user<br />
parameters). For details, see Sections 4.2.80, "Function code display restriction," (on page 4-74),<br />
4.2.81, "Initial-screen selection," (on page 4-76), and 4.2.82, "Automatic user-parameter setting," (on<br />
page 4-77).<br />
Item Function code Data Description<br />
00 Full display<br />
Function code display<br />
restriction<br />
Initial-screen selection<br />
(Initial display at<br />
power-on)<br />
Selection of automatic<br />
user-parameter settings<br />
b037<br />
b038<br />
(*1)<br />
*1 Not displayed with the factory setting<br />
01 Function-specific display<br />
02 User setting<br />
03 Data comparison display<br />
04 Basic display (factory setting)<br />
00<br />
Screen displayed when the [STR] key was pressed last<br />
(same as the operation on the SJ300 series)<br />
01 d001 (output frequency monitoring)<br />
02 d002 (output current monitoring)<br />
03 d003 (rotation direction minitoring)<br />
04 d007 (Scaled output frequency monitoring)<br />
05 F001 (output frequency setting)<br />
00 Disable<br />
b039<br />
(*1) 01 Enable<br />
* The following procedure enables you to turn the monitor display back to or (*1)<br />
regardless of the current display mode:<br />
- Hold down the FUNC key for 3 seconds or more. The monitor shows and (*1)<br />
alternately.<br />
FUNC<br />
During this status, press the key. The monitor will show only or (*1),<br />
which is shown when the<br />
FUNC<br />
is pressed.<br />
*1 The monitor shows only when the motor driven by the inverter is stopped. While the<br />
motor is running, the monitor shows an output frequency.<br />
3 - 4