Chapter 2 Installation and Wiring<br />

Terminal layout<br />

Charge lamp<br />

R0 T0<br />

Inverter model<br />

<strong>SJ700</strong>-300LFF<br />

R0 and T0: M4<br />

G<br />

R<br />

(L1)<br />

S<br />

(L2)<br />

T<br />

(L3)<br />

PD<br />

(+1)<br />

P<br />

(+)<br />

N<br />

(-)<br />

U<br />

(T1)<br />

V<br />

(T2)<br />

W<br />

(T3)<br />

G<br />

Ground terminal:<br />

M6<br />

Other terminals:<br />

M8<br />

Ground terminal with<br />

jumper (shaded in the<br />

figure) to enable/disable the<br />

EMC filter function<br />

[Method of enabling/disabling the EMC filter function]<br />

Jumper connecting<br />

terminals PD and P<br />

When not using the DCL,<br />

do not remove the jumper<br />

from terminals PD and P.<br />

<strong>SJ700</strong>-300HFF<br />

R0 and T0: M4<br />

Ground terminal:<br />

M6<br />

Other terminals:<br />

M6<br />

<strong>SJ700</strong>-370LFF<br />

<strong>SJ700</strong>-370HFF<br />

Enabling the EMC filter<br />

(factory setting :xFEF2)<br />

Disabling the EMC filter<br />

(factory setting :xFF2,xFUF2)<br />

R0 and T0: M4<br />

Ground terminal:<br />

M8<br />

Other terminals:<br />

M8<br />

charge lump<br />

R0 T0<br />

R<br />

(L1)<br />

S<br />

(L2)<br />

T<br />

(L3)<br />

PD<br />

(+1)<br />

P<br />

(+)<br />

N<br />

(-)<br />

U<br />

(T1)<br />

V<br />

(T2)<br />

W<br />

(T3)<br />

G<br />

G<br />

Jumper connecting<br />

Terminals PD and P<br />

When not using the DCL,<br />

do not remove the jumper<br />

from terminals PD and P.<br />

Ground terminal with<br />

jumper (shaded in the<br />

figure) to enable/disable the<br />

EMC filter function<br />

G<br />

<strong>SJ700</strong>-450LFF2<br />

<strong>SJ700</strong>-450HFF2<br />

<strong>SJ700</strong>-550HFF2<br />

[Method of enabling/disabling the EMC filter function]<br />

R0 and T0: M4<br />

Ground terminal:<br />

M8<br />

Other terminals: M8<br />

Enabling the EMC filter<br />

(factory setting :xFEF2)<br />

Disabling the EMC filter<br />

(factory setting :xFF2,xFUF2)<br />

2 - 15