Chapter 2 Installation and Wiring<br />

2.1.2 Backing plate<br />

(1) For models with 22 kW or less capacity<br />

On the backing plate, cut the joints around each section to be cut off with cutting pliers or a cutter,<br />

remove them, and then perform the wiring.<br />

Joint<br />

Section to be cut off<br />

(2) For the models with 30 kW to 55kW<br />

1) For wiring without using conduits<br />

Cut an X in each rubber bushing of the backing plate with cutting pliers or a cutter, and then perform<br />

the wiring.<br />

Backing plate<br />

Rubber bushing<br />

2) For wiring using conduits<br />

Remove the rubber bushings from the holes to be used for wiring with conduits, and then fit conduits<br />

into the holes.<br />

Note: Do not remove the rubber bushing from holes that are not used for wiring with a conduit.<br />

If a cable is connected through the plate hole without a rubber bushing and conduit, the cable<br />

insulation may be damaged by the edge of the hole, resulting in a short circuit or ground fault.<br />