Appendix<br />

Upgrading from the SJ300 Series<br />

The SJ300 series inverter is upwardly compatible with the <strong>SJ700</strong> series inverter. Therefore, you can:<br />

- mount the control circuit terminal block board of the SJ300 series in the <strong>SJ700</strong> series without removing<br />

the connected cables,<br />

- copy the parameter settings from the SJ300 series into the <strong>SJ700</strong> series, and<br />

- use the option boards mounted in the SJ300 series for the <strong>SJ700</strong> series without removing the connected<br />

cables.<br />

(1) Control circuit terminal block board<br />

You can mount the control circuit terminal<br />

block board of the SJ300 series into the<br />

<strong>SJ700</strong> series. Note, however, that the<br />

backing plate is incompatible.<br />

(Procedure for replacing the control circuit<br />

terminal block board)<br />

As shown in the figure on the right, the<br />

fixing screw locations on the control circuit<br />

terminal block board are common to the<br />

SJ300 and <strong>SJ700</strong> series.<br />

To remove and install the control circuit<br />

terminal block board, follow the steps 1) to<br />

5) described below.<br />

Control circuit terminal block board mounted in the<br />

SJ300/<strong>SJ700</strong> series (front view)<br />

Fixing screw (M3) x 2<br />

Board guide pin<br />

Fixing screw<br />

Connector<br />

(60 poles)<br />

Board guide pin x 2<br />

Board guide pin<br />

Fixing screw<br />

Precautions:<br />

Use care to prevent the control circuit terminal block board from twisting when removing or mounting it.<br />

Otherwise, the board guide pins and connector pins may be damaged.<br />

Do not pull the cables connected to the control circuit terminal block board when you remove the<br />

board from the SJ300 series.<br />

Do not forcibly insert the board into the mounting slot. Make sure that the board is correctly fitted onto<br />

the board guide pins and the connectors are correctly fitted to each other.<br />

SJ300 series<br />

<strong>SJ700</strong> series<br />

Removing the control circuit terminal block board from the<br />

SJ300 series<br />

1) Remove two fixing screws from the control circuit terminal<br />

block board.<br />

2) Pull the control circuit terminal block board straight toward<br />

you to remove it from the SJ300 series.<br />

Precautions:<br />

Pull out the board slowly.<br />

Be careful not to bend the connector pins.<br />

Be careful not to break the board guide pins.<br />

Mounting the removed control circuit terminal block board in<br />

the <strong>SJ700</strong> series<br />

3) Remove the original control circuit terminal block board<br />

from the <strong>SJ700</strong> series beforehand (as instructed in steps<br />

1) and 2)).<br />

4) Insert the control circuit terminal block board removed<br />

from the SJ300 series straight into the slot along the<br />

board guide pins and connector pins until it touches the<br />

fixing-screw seats.<br />

Precautions:<br />

Push in the board slowly.<br />

Be careful not to bend the connector pins.<br />

Be careful not to break the board guide pins.<br />

5) Secure the control circuit terminal block board with two<br />

fixing screws.<br />

Precaution:<br />

Be sure to fix the board with the two fixing screws.<br />