Chapter 8 List of Data Settings Code Function name Monitored data or setting Default _FF _FEF _FUF Setting during operation (allowed or not) Change during operation (allowed or not) Page User parameters U001 User-selected function 1 no/d001 to P131 no ◦ ◦ U002 User-selected function 2 no/d001 to P131 no ◦ ◦ U003 User-selected function 3 no/d001 to P131 no ◦ ◦ U004 User-selected function 4 no/d001 to P131 no ◦ ◦ U005 User-selected function 5 no/d001 to P131 no ◦ ◦ U006 User-selected function 6 no/d001 to P131 no ◦ ◦ U007 User-selected function 7 no/d001 to P131 no ◦ ◦ U008 User-selected function 8 no/d001 to P131 no ◦ ◦ U009 User-selected function 9 no/d001 to P131 no ◦ ◦ U010 User-selected function 10 no/d001 to P131 no ◦ ◦ U011 User-selected function 11 no/d001 to P131 no ◦ ◦ U012 User-selected function 12 no/d001 to P131 no ◦ ◦ 4-76 8 - 18

Appendix Upgrading from the SJ300 Series The SJ300 series inverter is upwardly compatible with the SJ700 series inverter. Therefore, you can: - mount the control circuit terminal block board of the SJ300 series in the SJ700 series without removing the connected cables, - copy the parameter settings from the SJ300 series into the SJ700 series, and - use the option boards mounted in the SJ300 series for the SJ700 series without removing the connected cables. (1) Control circuit terminal block board You can mount the control circuit terminal block board of the SJ300 series into the SJ700 series. Note, however, that the backing plate is incompatible. (Procedure for replacing the control circuit terminal block board) As shown in the figure on the right, the fixing screw locations on the control circuit terminal block board are common to the SJ300 and SJ700 series. To remove and install the control circuit terminal block board, follow the steps 1) to 5) described below. Control circuit terminal block board mounted in the SJ300/SJ700 series (front view) Fixing screw (M3) x 2 Board guide pin Fixing screw Connector (60 poles) Board guide pin x 2 Board guide pin Fixing screw Precautions: Use care to prevent the control circuit terminal block board from twisting when removing or mounting it. Otherwise, the board guide pins and connector pins may be damaged. Do not pull the cables connected to the control circuit terminal block board when you remove the board from the SJ300 series. Do not forcibly insert the board into the mounting slot. Make sure that the board is correctly fitted onto the board guide pins and the connectors are correctly fitted to each other. SJ300 series SJ700 series Removing the control circuit terminal block board from the SJ300 series 1) Remove two fixing screws from the control circuit terminal block board. 2) Pull the control circuit terminal block board straight toward you to remove it from the SJ300 series. Precautions: Pull out the board slowly. Be careful not to bend the connector pins. Be careful not to break the board guide pins. Mounting the removed control circuit terminal block board in the SJ700 series 3) Remove the original control circuit terminal block board from the SJ700 series beforehand (as instructed in steps 1) and 2)). 4) Insert the control circuit terminal block board removed from the SJ300 series straight into the slot along the board guide pins and connector pins until it touches the fixing-screw seats. Precautions: Push in the board slowly. Be careful not to bend the connector pins. Be careful not to break the board guide pins. 5) Secure the control circuit terminal block board with two fixing screws. Precaution: Be sure to fix the board with the two fixing screws. A - 1

Chapter 8 List of Data Settings<br />

Code Function name Monitored data or setting<br />

Default<br />

_FF _FEF _FUF<br />

Setting<br />

during<br />

operation<br />

(allowed or<br />

not)<br />

Change<br />

during<br />

operation<br />

(allowed or<br />

not)<br />

Page<br />

User parameters<br />

U001 User-selected function 1 no/d001 to P131 no ◦ ◦<br />

U002 User-selected function 2 no/d001 to P131 no ◦ ◦<br />

U003 User-selected function 3 no/d001 to P131 no ◦ ◦<br />

U004 User-selected function 4 no/d001 to P131 no ◦ ◦<br />

U005 User-selected function 5 no/d001 to P131 no ◦ ◦<br />

U006 User-selected function 6 no/d001 to P131 no ◦ ◦<br />

U007 User-selected function 7 no/d001 to P131 no ◦ ◦<br />

U008 User-selected function 8 no/d001 to P131 no ◦ ◦<br />

U009 User-selected function 9 no/d001 to P131 no ◦ ◦<br />

U010 User-selected function 10 no/d001 to P131 no ◦ ◦<br />

U011 User-selected function 11 no/d001 to P131 no ◦ ◦<br />

U012 User-selected function 12 no/d001 to P131 no ◦ ◦<br />

4-76<br />

8 - 18