Chapter 8 List of Data Settings<br />

Code Function name Monitored data or setting<br />

Default<br />

_FF _FEF _FUF<br />

Setting<br />

during<br />

operation<br />

(allowed<br />

or not)<br />

Change<br />

during<br />

operation<br />

(allowed<br />

or not)<br />

Page<br />

Control constants<br />

H050 PI proportional gain for 1st motor 0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

H250 PI proportional gain for 2nd motor 0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

H051 PI integral gain for 1st motor 0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

H251 PI integral gain for 2nd motor 0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

H052<br />

H252<br />

P proportional gain setting for 1st<br />

motor<br />

P proportional gain setting for 2nd<br />

motor<br />

0.01 to 10.00 1.00 ◦ ◦<br />

0.01 to 10.00 1.00 ◦ ◦<br />

H060 Zero LV lmit for 1st motor 0.0 to 100.0 100.0 ◦ ◦<br />

H260 Zero LV lmit for 2nd motor 0.0 to 100.0 100.0 ◦ ◦<br />

H061<br />

H261<br />

H070<br />

H071<br />

H072<br />

Zero LV starting boost current for<br />

1st motor<br />

Zero LV starting boost current for<br />

2nd motor<br />

Terminal selection PI proportional<br />

gain setting<br />

Terminal selection PI integral gain<br />

setting<br />

Terminal selection P proportional<br />

gain setting<br />

0. to 50. (%) 50. ◦ ◦<br />

0. to 50. (%) 50. ◦ ◦<br />

0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

0.0 to 999.9, 1000. 100.0 ◦ ◦<br />

0.00 to 10.00 1.00 ◦ ◦<br />

H073 Gain switching time 0. to 9999. (ms) 100. ◦ ◦<br />

4-58<br />

4-90<br />

4-58<br />

8 - 14