29.01.2015 Views

SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.

SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.

SJ700-2 Instruction Manual NT204DX - Hitachi America, Ltd.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 7 Specifications<br />

(3) Common specifications of 200 V class and 400 V class models (continued)<br />

Model name (type name)<br />

<strong>SJ700</strong>-XXXFF2.FEF2,FUF2<br />

Operating<br />

environment<br />

Optional boards<br />

Ambient<br />

temperature,<br />

storage<br />

temperature(note5),<br />

humidity<br />

Vibration tolerance<br />

(See Note 1.)<br />

Installation<br />

environment<br />

Coating color<br />

Feedback option<br />

Digital input option<br />

DeviceNet option<br />

LonWorks option<br />

Profibus-DP option<br />

Other optional components<br />

004<br />

L<br />

007<br />

L/H<br />

015<br />

L/H<br />

022<br />

L/H<br />

037<br />

(040)<br />

L/H<br />

055<br />

L/H<br />

075<br />

L/H<br />

110<br />

L/H<br />

150<br />

L/H<br />

-10°C to +50°C (ambient), -20°C to +65°C (storage), 20% to 90% RH (no condensation allowed)<br />

5.9m/s 2 (0.6G),10~55Hz<br />

185<br />

L/H<br />

220<br />

L/H<br />

300<br />

L/H<br />

370<br />

L/H<br />

450<br />

L/H<br />

Environment without corrosive gases and dust, at an altitude of 1,000 m or less<br />

Gray<br />

Vector control with sensor<br />

4-digit BCD input, 16-bit binary input<br />

Option to support the open-network DeviceNet function<br />

Option to support the open-network LonWorks function<br />

Option to support the open-network Profibus-DP function<br />

550<br />

L/H<br />

750<br />

H<br />

900<br />

H<br />

2.94m/s 2 (0.3G),10~55Hz<br />

Braking resistor, AC reactor, DC reactor, noise filter, operator cables, Harmonic-wave suppressor unit,<br />

LCR filter, analog operation panel, regenerative braking unit, controllers for various applications<br />

Note 1: The vibration tolerance was tested in compliance with JIS C0040 (1999).<br />

Note 2: The insulation distance complies with the UL and CE standards.<br />

Note3: The applicable motor refers to <strong>Hitachi</strong> standard 3-phase motor(4-pole).when using other motors,care must be taken to prevent<br />

the rated motor current(50/60Hz)from exceeding the rated output current of the inverter.<br />

Note4:Function “64(EMR)”cannot be assigned to input terminal 3 by an operation from the operator. The function is automatically<br />

assigned to the terminal when slide switch SW1 is set to ON.<br />

Note5:The storage temperature refers to the short-term temperature during transport.<br />

Note6:The frequency command will equal the maximum frequency at 9.8V for input voltage 0 to 10VDC,or at 19.8mA for input current<br />

4 to 20mA.If this characteristic is not satisfactory for your application, contact your <strong>Hitachi</strong> sales representative.<br />

1100<br />

H<br />

1320<br />

(1500)<br />

H<br />

7 - 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!