Chapter 4 Explanation of Functions<br />

(vi) List of registers (2nd control settings)<br />

Register<br />

No.<br />

Function name Function code R/W Monitoring and setting items Data resolution<br />

2103h Acceleration (1) time setting, 2nd F202 (high) R/W<br />

2104h motor F202 (low) R/W<br />

Register<br />

No.<br />

1 to 360000 0.01 [sec.]<br />

2105h F203 (high) R/W<br />

Deceleration time, 2nd motor<br />

1 to 360000 0.01 [sec.]<br />

2106h<br />

F203 (low) R/W<br />

2107h to<br />

(Reserved) - - Inaccessible -<br />

2202h<br />

(vii) List of registers (function modes for the 2nd control settings)<br />

Register<br />

No.<br />

Function name<br />

Function<br />

code<br />

R/W<br />

Monitoring and setting items Data resolution<br />

Register<br />

No.<br />

2203h<br />

Base frequency setting, 2nd<br />

motor<br />

A203 R/W 30 to "maximum frequency, 2nd motor" 1 [Hz]<br />

2204h<br />

Maximum frequency setting,<br />

2nd motor<br />

A204 R/W 30 to 400 1 [Hz]<br />

2205h to<br />

2215h<br />

(Reserved) - - Inaccessible -<br />

2216h Multispeed frequency setting, A220 (high) R/W 0 or "start frequency" to "maximum frequency,<br />

2217h 2nd motor A220 (low) R/W 2nd motor"<br />

0.01 [Hz]<br />

2218h to<br />

223Ah<br />

(Reserved) - - Inaccessible -<br />

223Bh<br />

Torque boost method selection,<br />

0 (manual torque boost), 1 (automatic torque<br />

A241 R/W<br />

2nd motor<br />

boost)<br />

-<br />

223Ch<br />

<strong>Manual</strong> torque boost value,<br />

2nd motor<br />

A242 R/W 0 to 200 0.1 [%]<br />

223Dh<br />

<strong>Manual</strong> torque boost frequency<br />

adjustment, 2nd motor<br />

A243 R/W 0 to 500 0.1 [%]<br />

223Eh<br />

V/F characteristic curve<br />

0 (VC), 1 (VP), 2 (free V/f), 3 (sensorless vector<br />

A244 R/W<br />

selection, 2nd motor<br />

control), 4 (0Hz-range sensorless vector)<br />

-<br />

223Fh (Reserved) - - Inaccessible -<br />

2240h<br />

Voltage compensation gain<br />

setting for automatic torque A246 R/W 0 to 255 1<br />

boost, 2nd motor<br />

2241h<br />

Slippage compensation gain<br />

setting for automatic torque A247 R/W 0 to 255 1<br />

boost, 2nd motor<br />

2242h to<br />

224Eh<br />

(Reserved) - - Inaccessible -<br />

224Fh Frequency upper limit setting, A261 (high) R/W 00 or "2nd minimum frequency limit" to<br />

2250h 2nd motor A261 (low) R/W "maximum frequency, 2nd motor"<br />

0.01 [Hz]<br />

2251h Frequency lower limit setting, A262 (high) R/W 00 or "start frequency" to "maximum frequency,<br />

2252h 2nd motor A262 (low) R/W 2nd motor limit"<br />

0.01 [Hz]<br />

2253h to<br />

226Eh<br />

(Reserved) - - Inaccessible -<br />

226Fh Acceleration (2) time setting, A292 (high) R/W<br />

2270h 2nd motor A292 (low) R/W<br />

1 to 360000 0.01 [sec.]<br />

2271h Deceleration (2) time setting, A293 (high) R/W<br />

2272h 2nd motor A293 (low) R/W<br />

1 to 360000 0.01 [sec.]<br />

2273h<br />

0 (switching by 2CH terminal), 1 (switching by<br />

Select method to switch to<br />

A294 R/W setting), 2 (switching only when the rotation is<br />

Acc2/Dec2, 2nd motor<br />

reversed)<br />

-<br />

2274h Acc1 to Acc2 frequency A295 (high) R/W<br />

2275h transition point, 2nd motor A295 (low) R/W<br />

0 to 40000 0.01 [Hz]<br />

2276h Dec1 to Dec2 frequency A296 (high) R/W<br />

2277h transition point, 2nd motor A296 (low) R/W<br />

0 to 40000 0.01 [Hz]<br />

2278h to<br />

230Bh<br />

(Reserved) - - Inaccessible -<br />

4 - 161