Chapter 4 Explanation of Functions<br />
(vi) List of registers (2nd control settings)<br />
Register<br />
No.<br />
Function name Function code R/W Monitoring and setting items Data resolution<br />
2103h Acceleration (1) time setting, 2nd F202 (high) R/W<br />
2104h motor F202 (low) R/W<br />
Register<br />
No.<br />
1 to 360000 0.01 [sec.]<br />
2105h F203 (high) R/W<br />
Deceleration time, 2nd motor<br />
1 to 360000 0.01 [sec.]<br />
2106h<br />
F203 (low) R/W<br />
2107h to<br />
(Reserved) - - Inaccessible -<br />
2202h<br />
(vii) List of registers (function modes for the 2nd control settings)<br />
Register<br />
No.<br />
Function name<br />
Function<br />
code<br />
R/W<br />
Monitoring and setting items Data resolution<br />
Register<br />
No.<br />
2203h<br />
Base frequency setting, 2nd<br />
motor<br />
A203 R/W 30 to "maximum frequency, 2nd motor" 1 [Hz]<br />
2204h<br />
Maximum frequency setting,<br />
2nd motor<br />
A204 R/W 30 to 400 1 [Hz]<br />
2205h to<br />
2215h<br />
(Reserved) - - Inaccessible -<br />
2216h Multispeed frequency setting, A220 (high) R/W 0 or "start frequency" to "maximum frequency,<br />
2217h 2nd motor A220 (low) R/W 2nd motor"<br />
0.01 [Hz]<br />
2218h to<br />
223Ah<br />
(Reserved) - - Inaccessible -<br />
223Bh<br />
Torque boost method selection,<br />
0 (manual torque boost), 1 (automatic torque<br />
A241 R/W<br />
2nd motor<br />
boost)<br />
-<br />
223Ch<br />
<strong>Manual</strong> torque boost value,<br />
2nd motor<br />
A242 R/W 0 to 200 0.1 [%]<br />
223Dh<br />
<strong>Manual</strong> torque boost frequency<br />
adjustment, 2nd motor<br />
A243 R/W 0 to 500 0.1 [%]<br />
223Eh<br />
V/F characteristic curve<br />
0 (VC), 1 (VP), 2 (free V/f), 3 (sensorless vector<br />
A244 R/W<br />
selection, 2nd motor<br />
control), 4 (0Hz-range sensorless vector)<br />
-<br />
223Fh (Reserved) - - Inaccessible -<br />
2240h<br />
Voltage compensation gain<br />
setting for automatic torque A246 R/W 0 to 255 1<br />
boost, 2nd motor<br />
2241h<br />
Slippage compensation gain<br />
setting for automatic torque A247 R/W 0 to 255 1<br />
boost, 2nd motor<br />
2242h to<br />
224Eh<br />
(Reserved) - - Inaccessible -<br />
224Fh Frequency upper limit setting, A261 (high) R/W 00 or "2nd minimum frequency limit" to<br />
2250h 2nd motor A261 (low) R/W "maximum frequency, 2nd motor"<br />
0.01 [Hz]<br />
2251h Frequency lower limit setting, A262 (high) R/W 00 or "start frequency" to "maximum frequency,<br />
2252h 2nd motor A262 (low) R/W 2nd motor limit"<br />
0.01 [Hz]<br />
2253h to<br />
226Eh<br />
(Reserved) - - Inaccessible -<br />
226Fh Acceleration (2) time setting, A292 (high) R/W<br />
2270h 2nd motor A292 (low) R/W<br />
1 to 360000 0.01 [sec.]<br />
2271h Deceleration (2) time setting, A293 (high) R/W<br />
2272h 2nd motor A293 (low) R/W<br />
1 to 360000 0.01 [sec.]<br />
2273h<br />
0 (switching by 2CH terminal), 1 (switching by<br />
Select method to switch to<br />
A294 R/W setting), 2 (switching only when the rotation is<br />
Acc2/Dec2, 2nd motor<br />
reversed)<br />
-<br />
2274h Acc1 to Acc2 frequency A295 (high) R/W<br />
2275h transition point, 2nd motor A295 (low) R/W<br />
0 to 40000 0.01 [Hz]<br />
2276h Dec1 to Dec2 frequency A296 (high) R/W<br />
2277h transition point, 2nd motor A296 (low) R/W<br />
0 to 40000 0.01 [Hz]<br />
2278h to<br />
230Bh<br />
(Reserved) - - Inaccessible -<br />
4 - 161