Chapter 4 Explanation of Functions Register Monitoring and setting items Data Register Function name Function code R/W No. resolution No. 1681h Easy sequence user parameter U (27) P127 R/W 0 to 65530 1 1682h Easy sequence user parameter U (28) P128 R/W 0 to 65530 1 1683h Easy sequence user parameter U (29) P129 R/W 0 to 65530 1 1684h Easy sequence user parameter U (30) P130 R/W 0 to 65530 1 1685h Easy sequence user parameter U (31) P131 R/W 0 to 65530 1 1686h to 2102h (Reserved) - - Inaccessible - *1 The following table lists the code data for parameter "H003" (motor capacity selection): Code data 00 01 02 03 04 05 06 07 08 09 10 Japan or U.S.A. mode (b085 = 00 or 02) 0.2 kW - 0.4 - 0.75 - 1.5 2.2 - 3.7 - EU mode (b085 = 01) 0.2 kW 0.37 - 0.55 0.75 1.1 1.5 2.2 3.0 - 4.0 Code data 11 12 13 14 15 16 17 18 19 20 21 Japan or U.S.A. mode (b085 = 00 or 02) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75 EU mode (b085 = 01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75 Code data 22 23 24 25 26 Japan or U.S.A. mode (b085 = 00 or 02) 90kW 110 132 150 160 EU mode (b085 = 01) 90kW 110 132 150 160 4 - 160

Chapter 4 Explanation of Functions (vi) List of registers (2nd control settings) Register No. Function name Function code R/W Monitoring and setting items Data resolution 2103h Acceleration (1) time setting, 2nd F202 (high) R/W 2104h motor F202 (low) R/W Register No. 1 to 360000 0.01 [sec.] 2105h F203 (high) R/W Deceleration time, 2nd motor 1 to 360000 0.01 [sec.] 2106h F203 (low) R/W 2107h to (Reserved) - - Inaccessible - 2202h (vii) List of registers (function modes for the 2nd control settings) Register No. Function name Function code R/W Monitoring and setting items Data resolution Register No. 2203h Base frequency setting, 2nd motor A203 R/W 30 to "maximum frequency, 2nd motor" 1 [Hz] 2204h Maximum frequency setting, 2nd motor A204 R/W 30 to 400 1 [Hz] 2205h to 2215h (Reserved) - - Inaccessible - 2216h Multispeed frequency setting, A220 (high) R/W 0 or "start frequency" to "maximum frequency, 2217h 2nd motor A220 (low) R/W 2nd motor" 0.01 [Hz] 2218h to 223Ah (Reserved) - - Inaccessible - 223Bh Torque boost method selection, 0 (manual torque boost), 1 (automatic torque A241 R/W 2nd motor boost) - 223Ch Manual torque boost value, 2nd motor A242 R/W 0 to 200 0.1 [%] 223Dh Manual torque boost frequency adjustment, 2nd motor A243 R/W 0 to 500 0.1 [%] 223Eh V/F characteristic curve 0 (VC), 1 (VP), 2 (free V/f), 3 (sensorless vector A244 R/W selection, 2nd motor control), 4 (0Hz-range sensorless vector) - 223Fh (Reserved) - - Inaccessible - 2240h Voltage compensation gain setting for automatic torque A246 R/W 0 to 255 1 boost, 2nd motor 2241h Slippage compensation gain setting for automatic torque A247 R/W 0 to 255 1 boost, 2nd motor 2242h to 224Eh (Reserved) - - Inaccessible - 224Fh Frequency upper limit setting, A261 (high) R/W 00 or "2nd minimum frequency limit" to 2250h 2nd motor A261 (low) R/W "maximum frequency, 2nd motor" 0.01 [Hz] 2251h Frequency lower limit setting, A262 (high) R/W 00 or "start frequency" to "maximum frequency, 2252h 2nd motor A262 (low) R/W 2nd motor limit" 0.01 [Hz] 2253h to 226Eh (Reserved) - - Inaccessible - 226Fh Acceleration (2) time setting, A292 (high) R/W 2270h 2nd motor A292 (low) R/W 1 to 360000 0.01 [sec.] 2271h Deceleration (2) time setting, A293 (high) R/W 2272h 2nd motor A293 (low) R/W 1 to 360000 0.01 [sec.] 2273h 0 (switching by 2CH terminal), 1 (switching by Select method to switch to A294 R/W setting), 2 (switching only when the rotation is Acc2/Dec2, 2nd motor reversed) - 2274h Acc1 to Acc2 frequency A295 (high) R/W 2275h transition point, 2nd motor A295 (low) R/W 0 to 40000 0.01 [Hz] 2276h Dec1 to Dec2 frequency A296 (high) R/W 2277h transition point, 2nd motor A296 (low) R/W 0 to 40000 0.01 [Hz] 2278h to 230Bh (Reserved) - - Inaccessible - 4 - 161

Chapter 4 Explanation of Functions<br />

Register<br />

Monitoring and setting items Data Register<br />

Function name Function code R/W<br />

No.<br />

resolution<br />

No.<br />

1681h Easy sequence user parameter U (27) P127 R/W 0 to 65530 1<br />

1682h Easy sequence user parameter U (28) P128 R/W 0 to 65530 1<br />

1683h Easy sequence user parameter U (29) P129 R/W 0 to 65530 1<br />

1684h Easy sequence user parameter U (30) P130 R/W 0 to 65530 1<br />

1685h Easy sequence user parameter U (31) P131 R/W 0 to 65530 1<br />

1686h to<br />

2102h<br />

(Reserved) - - Inaccessible -<br />

*1 The following table lists the code data for parameter "H003" (motor capacity selection):<br />

Code data 00 01 02 03 04 05 06 07 08 09 10<br />

Japan or U.S.A. mode<br />

(b085 = 00 or 02)<br />

0.2 kW - 0.4 - 0.75 - 1.5 2.2 - 3.7 -<br />

EU mode (b085 = 01) 0.2 kW 0.37 - 0.55 0.75 1.1 1.5 2.2 3.0 - 4.0<br />

Code data 11 12 13 14 15 16 17 18 19 20 21<br />

Japan or U.S.A. mode<br />

(b085 = 00 or 02)<br />

5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75<br />

EU mode (b085 = 01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75<br />

Code data 22 23 24 25 26<br />

Japan or U.S.A. mode<br />

(b085 = 00 or 02)<br />

90kW 110 132 150 160<br />

EU mode (b085 = 01) 90kW 110 132 150 160<br />

4 - 160