Chapter 4 Explanation of Functions<br />

Register<br />

No.<br />

Function name<br />

Function<br />

code<br />

R/W<br />

4 - 151<br />

Monitoring and setting items Data resolution<br />

1326h Reduced voltage start selection b036 R/W<br />

0 (minimum reduced voltage start time) to 255<br />

(maximum reduced voltage start time)<br />

-<br />

1327h Function code display restriction b037 R/W<br />

0 (full display), 1 (function-specific display), 2 (user<br />

setting), 3 (data comparison display), 4 (basicdisplay)<br />

-<br />

1328h Initial-screen selection b038 R/W<br />

0 (screen displayed when the STR key was pressed<br />

last), 1 (d001), 2 (d002), 3 (d003), 4 (d007), 5 (F001)<br />

-<br />

1329h<br />

Automatic user-parameter<br />

setting function enable<br />

b039 R/W 0 (disabling), 1 (enabling) -<br />

132Ah Torque limit selection b040 R/W<br />

00 (quadrant-specific setting), 01 (switching by<br />

terminal), 02 (analog input), 03 (option 1),<br />

04 (option 2)<br />

Register<br />

No.<br />

132Bh<br />

Torque limit (1) (forward-driving<br />

in 4-quadrant mode)<br />

b041 R/W 0 to 200/255 (no) 1 [%]<br />

132Ch<br />

Torque limit (2)<br />

(reverse-regenerating in<br />

b042 R/W 0 to 200/255 (no) 1 [%]<br />

4-quadrant mode)<br />

132Dh<br />

Torque limit (3) (reverse-driving<br />

in 4-quadrant mode)<br />

b043 R/W 0 to 200/255 (no) 1 [%]<br />

132Eh<br />

Torque limit (4)<br />

(forward-regenerating in<br />

b044 R/W 0 to 200/255 (no) 1 [%]<br />

4-quadrant mode)<br />

132Fh Torque limit LADSTOP enable b045 R/W 0 (disabling), 1 (enabling) -<br />

1330h Reverse Run protection enable b046 R/W 0 (disabling), 1 (enabling) -<br />

1331h to<br />

1333h<br />

1334h<br />

(Reserved) - - Inaccessible -<br />

Controller deceleration and stop<br />

on power loss<br />

b050<br />

R/W<br />

0 (disabling), 1 (enabling), 2, (nonstop operation at<br />

momentary power failure (no restoration))<br />

3, (nonstop operation at momentary power failure<br />

(restoration to be done))<br />

1335h<br />

DC bus voltage trigger level<br />

during power loss<br />

b051 R/W 0 to 10000 0.1 [V]<br />

1336h<br />

Over-voltage threshold during<br />

power loss<br />

b052 R/W 0 to 10000 0.1 [V]<br />

1337h Deceleration time setting during b053 (high) R/W<br />

1338h power loss (target voltage level) b053 (low) R/W 0 to 360000 0.01<br />

[sec.]<br />

1339h<br />

Initial output frequency decrease<br />

during power loss<br />

b054 R/W 0 to 1000 0.01 [Hz]<br />

133Ah<br />

Proportional gain setting for<br />

nonstop operation at momentary<br />

power failure<br />

b055 R/W 0 to 255 0.01<br />

133Bh<br />

133Ch to<br />

133Eh<br />

Integral time setting for nonstop<br />

operation at momentary power<br />

failure<br />

b056 R/W 0 to 65535<br />

(Reserved) - - Inaccessible -<br />

133Fh<br />

Maximum-limit level of window<br />

comparators O<br />

b060 R/W 0. to 100. (lower limit : b061 + b062 *2) (%) 1 [%]<br />

1340h<br />

Minimum-limit level of window<br />

comparators O<br />

b061 R/W 0. to 100. (lower limit : b060 - b062*2) (%) 1 [%]<br />

1341h<br />

Hysteresis width of window<br />

comparators O<br />

b062 R/W 0. to 10. (lower limit : b061 - b062 / 2) (%) 1 [%]<br />

1342h<br />

Maximum-limit level of window<br />

comparators OI<br />

b063 R/W 0. to 100. (lower limit : b064 + b066 *2) (%) 1 [%]<br />

1343h<br />

Minimum-limit level of window<br />

comparators OI<br />

b064 R/W 0. to 100. (lower limit : b063 - b066 *2) (%) 1 [%]<br />

1344h<br />

Hysteresis width of window<br />

comparators OI<br />

b065 R/W 0. to 10. (lower limit : b063 - b064 / 2) (%) 1 [%]<br />

1345h<br />

Maximum-limit level of window<br />

comparators OI<br />

b066 R/W -100. to 100. (lower limit : b067 + b068 *2) (%) 1 [%]<br />

1346h<br />

Minimum-limit level of window<br />

comparators O/OI/O2<br />

b067 R/W -100. to 100. (lower limit : b066 - b068 * 2) (%) 1 [%]<br />

1347h<br />

Hysteresis width of window<br />

comparators O/OI/O2<br />

b068 R/W 0. to 10. (lower limit : b066 - b067 / 2) (%) 1 [%]<br />

1348h (Reserved) - - Inaccessible -<br />

1349h<br />

Operation level at O<br />

disconnection<br />

b070 R/W 0. to 100. (%) or "no" (ignore) 1 [%]<br />

134Ah<br />

Operation level at OI<br />

disconnection<br />

b071 R/W 0. to 100. (%) or "no" (ignore) 1 [%]<br />

134Bh<br />

Operation level at O2<br />

disconnection<br />

b072 R/W -100. to 100. (%) or "no" (ignore) 1 [%]<br />

134Ch to<br />

1350<br />

1351h<br />

1352h<br />

(reserved) - - Inaccessible -<br />

Cumulative input power data<br />

clearance<br />

Cumulative input power display<br />

gain setting<br />

b060 R/W Clearance by setting "1" -<br />

-<br />

-<br />

0.001<br />

[sec]<br />

b060 R/W 1 to 1000 1