Chapter 4 Explanation of Functions<br />

(vii) 06 command: This command reads a specified setting item from the inverter.<br />

- Transmission frame<br />

Frame format<br />

STX Station No. Command Parameter BCC CR<br />

Description Data size Setting<br />

STX Control code (Start of TeXt) 1 byte STX (0x02)<br />

Station No.<br />

Station number of control-target<br />

inverter<br />

2 bytes 01 to 32<br />

Command Command to be transmitted 2 bytes 06<br />

Parameter Data parameter number 4 bytes See Note 12.<br />

BCC Block check code 2 bytes<br />

XOR of the items from "Station No." to "Data."<br />

See Item (3) of this section.<br />

CR Control code (Carriage Return) 1 byte CR (0x0D)<br />

Note 12: The parameters that can be specified for reading are F002 to F004, A001 to A153, b001 to b132,<br />

C001 to C159, H003 to H073, and P001 to P131. (To read the F001 parameter, use the 01<br />

command.)<br />

- Response frame<br />

Positive response:<br />

Frame format<br />

STX Station No. ACK Data BCC CR<br />

Description Data size Setting<br />

STX Control code (Start of TeXt) 1 byte STX (0x02)<br />

Station No.<br />

Station number of control-target<br />

inverter<br />

2 bytes 01 to 32<br />

ACK Control code (acknowledgement) 1 byte ACK (0x06)<br />

Data<br />

Data to be sent (decimal ASCII<br />

code)<br />

8 bytes See Note 13.<br />

BCC Block check code 2 bytes<br />

XOR of the items from "Station No." to "Data."<br />

See Item (3) of this section.<br />

CR Control code (Carriage Return) 1 byte CR (0x0D)<br />

Note 13: When the read parameter is an selection item, the Data part contains the code data<br />

corresponding to the selection.<br />

The code data corresponding to "H003" or "H203" (motor capacity selection) is as follows:<br />

Code data 00 01 02 03 04 05 06 07 08 09 10<br />

Japan or U.S.A. mode 0.2 kW - 0.4 - 0.75 - 1.5 2.2 - 3.7 -<br />

(b085 = 00 or 02)<br />

EU mode (b085 = 01) 0.2 kW 0.37 - 0.55 0.75 1.1 1.5 2.2 3.0 - 4.0<br />

Code data 11 12 13 14 15 16 17 18 19 20 21<br />

Japan or U.S.A. mode 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75<br />

(b085 = 00 or 02)<br />

EU mode (b085 = 01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75<br />

Code data 22 23 24 25 26<br />

Japan or U.S.A. mode 90kW 110 132 150 160<br />

(b085 = 00 or 02)<br />

EU mode (b085 = 01) 90kW 110 132 150 160<br />

For the value contained in the Data part when the read parameter is a numerical item, see the list of<br />

function codes.<br />

(Example) When the setting of the acceleration (1) time (F002) is 30.00 seconds, the Data part contains<br />

"3000".<br />

Negative response: See Item (2)-(ii) of this section.<br />