Chapter 4 Explanation of Functions<br />

4.3.14 Multistage position switching function (CP1/CP2/CP3)<br />

- When functions "66" (CP1) to "68" (CP3) are assigned to terminal [1] function (C001) to terminal [8]<br />

function (C008), you can select a position setting from multistage positions 0 to 7.<br />

- Use multistage position settings 0 to 7 (P060 to P067) for the position settings.<br />

- If no position settings are assigned to terminals, multistage position setting 0 (P060) is assumed.<br />

Position setting CP3 CP2 CP1<br />

Multistage position setting 0 0 0 0<br />

Multistage position setting 1 0 0 1<br />

Multistage position setting 2 0 1 0<br />

Multistage position setting 3 0 1 1<br />

Multistage position setting 4 1 0 0<br />

Multistage position setting 5 1 0 1<br />

Multistage position setting 6 1 1 0<br />

- You can specify a delay to be applied at multistage position setting input, until the relevant terminal input<br />

is determined. Use this specification to prevent the application of fluctuating terminal input before it is<br />

determined.<br />

- You can adjust the determination time with the multistage speed/position determination time setting<br />

(C169). The input data is finally determined when the terminal input becomes stable after the delay set as<br />

C169. (Note that a long determination time deteriorates the input terminal response.)<br />

Determination time (C169) = 0<br />

3<br />

Position command<br />

1<br />

7<br />

Determination time (C169) specified<br />

5<br />

4<br />

CP1<br />

CP2<br />

CP3<br />

4.3.15 Speed/position switching function (SPD)<br />

Determination time<br />

(C169)<br />

- To perform speed control operation in absolute position control mode, turn on the SPD terminal.<br />

- While the SPD terminal is off, the current position count remains at 0. Therefore, if the SPD terminal is<br />

turned off during operation, the control operation is switched to position control operation based on the<br />

position where the terminal is turned off. (Speed control operation is switched to position control<br />

operation.)<br />

- If the position setting is 0 at this time, the inverter stops the motor at that position.<br />

(Hunting may occur if a certain position loop gain value has been set.)<br />

- While the SPD terminal is on, the rotating direction depends on the operation command. When switching<br />

from speed control to position control, pay attention to the sign of the value set in the operation command.<br />

Output frequency<br />

Start of position counting<br />

Speed control<br />

Position control<br />

Time<br />

SPD terminal<br />

ON<br />

4 - 109<br />