Chapter 4 Explanation of Functions<br />

(1) Binary operation mode<br />

Assign functions "02" (CF1) to "05" (CF4) individually to the terminal [1] to [8] functions (C001 to C008) to<br />

make multispeed s 0 to 15 available for selection.<br />

Specify the desired frequencies for speeds 1 to 15 by setting multispeeds 1 to 15 (A021 to A035).<br />

You can set speed 0 by using function "A020", "A220", "A320", or "F001" (see Section 4.2.1) when you<br />

have specified the digital operator for the frequency source setting. You can set speed 0 by using the O, OI,<br />

or O2 terminal when you have specified the control circuit board for the frequency source setting.<br />

Multispeed CF4 CF3 CF2 CF1<br />

Speed 0 OFF OFF OFF OFF<br />

Speed 1 OFF OFF OFF ON<br />

Speed 2 OFF OFF ON OFF<br />

Speed 3 OFF OFF ON ON<br />

Speed 4 OFF ON OFF OFF<br />

Speed 5 OFF ON OFF ON<br />

Speed 6 OFF ON ON OFF<br />

Speed 7 OFF ON ON ON<br />

Speed 8 ON OFF OFF OFF<br />

Speed 9 ON OFF OFF ON<br />

Speed 10 ON OFF ON OFF<br />

Speed 11 ON OFF ON ON<br />

Speed 12 ON ON OFF OFF<br />

Speed 13 ON ON OFF ON<br />

Speed 14 ON ON ON OFF<br />

Speed 15 ON ON ON ON<br />

CF1<br />

CF2<br />

CF3<br />

CF4<br />

- With multispeed binary operation mode, you can use the multistage speed/position determination time<br />

setting (C169) to specify a delay to be set until the relevant terminal input is determined. Use this<br />

specification to prevent the application of fluctuating terminal input before it is determined.<br />

- The input data is finally determined when terminal input becomes stable after the delay set as C169.<br />

(Note that a long determination time deteriorates the input terminal response.)<br />

Determination time (C169) = 0<br />

Frequenc<br />

CF1<br />

CF2<br />

CF3<br />

CF4<br />

(2) Bit operation mode<br />

- Assign functions "32" (SF1) to "38" (SF7) individually to the terminal [1] to [8] functions (C001 to C008) to<br />

make multispeed s 0 to 7 available for selection.<br />

Speed 0<br />

- Specify the desired frequencies for speeds 1 to 7 (SF1 to SF7)<br />

by setting multispeeds 1 to 7 (A021 to A027).<br />

Speed 4<br />

Multispeed SF7 SF6 SF5 SF4 SF3 SF2 SF1<br />

Speed 0 OFF OFF OFF OFF OFF OFF OFF<br />

Speed 1 × × × × × × ON<br />

Speed 2 × × × × × ON OFF<br />

Speed 3 × × × × ON OFF OFF<br />

Speed 4 × × × ON OFF OFF OFF<br />

Speed 5 × × ON OFF OFF OFF OFF<br />

Speed 6 × ON OFF OFF OFF OFF OFF<br />

Speed 7 ON OFF OFF OFF OFF OFF OFF<br />

1<br />

11<br />

9<br />

15<br />

FW<br />

Speed 2<br />

Speed 1<br />

Speed 3<br />

If two or more input terminals are turned on at the same<br />

time, the terminal given the smallest terminal number FW<br />

among them has priority over others. The "X" mark in the above table indicates that the speed can be<br />

selected, regardless of whether or not the corresponding terminal is turned on.<br />

Speed 4<br />

Determination time<br />

4 - 49<br />

Speed 9<br />

Speed 5<br />

Speed 6<br />

Speed 7<br />

13<br />

5<br />

SF1<br />

SF2<br />

SF3<br />

SF4<br />

SF5<br />

SF6<br />

SF7<br />

Speed 8<br />

Speed 10<br />

4<br />

Speed 11<br />

Speed 3<br />

Speed 2<br />

Speed 1<br />

Speed 12<br />

Speed 13<br />

Speed 14<br />

Speed 15<br />

Speed 0<br />

Speed 5<br />

Speed 6<br />

Speed 7<br />

Frequency input from<br />

the digital operator or<br />

via an external analog<br />

input terminal<br />

Determination time (C169) specified<br />

Frequency input from<br />

the digital operator or<br />

via an external analog<br />

input terminal<br />

Speed 1