Chapter 4 Explanation of Functions<br />

(2) Overload nitice function<br />

The overload notice function allows you to make the inverter output an overload notice signal before<br />

tripping because of overload.<br />

You can use this function effectively to prevent the machine (e.g., a conveyor)driven by the inverter from<br />

being overloaded and prevent the conveyor from being stopped by the overload protection of the inverter.<br />

To use this function, assign function "03" (OK) or "26" (OL2) to one of the intelligent output terminals [11] to<br />

[15] (C021 to C025) and the alarm relay terminal (C026). (Two types of overload notice signal are available<br />

for output.)<br />

Item Function code Data or range of data Description<br />

Enabling the warning output during<br />

Overload signal output<br />

00<br />

C040<br />

acceleration, deceleration, and constant<br />

mode<br />

01 Enabling the warning output during constant<br />

0.0 Disabling the warning output<br />

Specifying the current at which to output the<br />

Overload level setting C041 0.1 to "2.0 x rated<br />

OL signal (overload notice advance signal<br />

current" (A)<br />

(1))<br />

0.0 Disabling the warning output<br />

Overload setting (2) C111 0.1 to "2.0 x rated<br />

current" (A)<br />

(NOTE) :applied for 75 to 150kW<br />

Overload restriction<br />

setting b022/b025<br />

Overload level setting<br />

C041/C111<br />

Specifying the current at which to output the<br />

OL2 signal (overload notice advance signal<br />

(2))<br />

Output current<br />

OL/OL2 output<br />

4.2.31 Overcurrent restraint<br />

Related code<br />

The overcurrent restraint function allows you to restrain the<br />

b027: Overcurrent suppression enable<br />

overcurrent that can occur when the output current sharply increases<br />

because of rapid acceleration.<br />

You can enable or disable the function by setting the overcurrent suppression enable (b027).<br />

Item Function code Data or range of data Description<br />

Overcurrent<br />

00 Disabling the overcurrent restraint<br />

b027<br />

suppression enable<br />

01 Enabling the overcurrent restraint<br />

Note: When using the inverter for a lift, disable the overcurrent restraint function. If the overcurrent<br />

restraint functions during the lift operation, the lift may slide down because of insufficient torque.<br />

4 - 41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!