<strong>Environmental</strong> <strong>Impact</strong>s of Postulated Accidents<br />

0 SAMA 2-enhance DC power availability by providing a direct connection from diesel<br />

generator 13, the security diesel, or another source, to the 250-V battery chargers or other.<br />

required loads.<br />

* SAMA 4-install a direct-drive diesel injection pump as additional high-pressure injection<br />

system.<br />

• SAMA 6-install additional fan and louver pair for emergency diesel generator heating,<br />

ventilation, and air conditioning.<br />

* SAMA 11--enhance alternate injection reliability by including the residual heat removal<br />

service water and fire service water cross-tie valves in the maintenance program.<br />

* SAMA 12-proceduralize the use of a fire pumper truck to pressurize the fire service water<br />

system.<br />

" SAMA 16-provide passive overpressure relief by changing the containment vent valves to<br />

fail open and improving the strength of the rupture disk.<br />

" SAMA 36--install an interlock to open the door to hot machine shop and change swing<br />

direction of door to plant administration building to divert water from turbine building<br />

931-foot elevation east.<br />

When benefits are evaluated using a three-percent discount rate, two additional SAMAs were<br />

determined to be potentially cost-beneficial:<br />

* SAMA 39-upgrade the automatic shutdown system (ASDS) panel to include additional<br />

system controls for opposite division.<br />

* SAMA 40-add emergency level control sensor and control valve to the hotwell.<br />

NMC performed additional analyses to evaluate the impact of parameter choices and<br />

uncertainties on the results of the SAMA assessment (NMC 2005a). If the benefits are<br />

increased by a factor of 2.5 to account for uncertainties, one additional SAMA (SAMA 9,<br />

dedicated alternate low-pressure injection/drywell spray system) was determined to be<br />

potentially cost-beneficial.<br />

NMC recognized that a combination of low-cost SAMAs could provide much of the risk<br />

reduction associated with higher-cost SAMAs, and may act synergistically to yield a combined<br />

risk reduction greater than the sum of the benefits of each SAMA if implemented individually<br />

(NMC 2005a). NMC identified six low-cost SAMAs as a recommended combination of SAMAs<br />

which substantially reduces risk at Monticello for a relatively low cost of implementation. These<br />

include previously identified SAMAs 2, 11, 12, and 36, and two additional SAMAs not identified<br />

as being cost-beneficial:<br />

August 2006 5-9 NUREG-1437, Supplement 26 1