Installation Assessment<br />

MP4 Methodology<br />

MP4 deliverables<br />

4 improvement plans <strong>in</strong>clud<strong>in</strong>g critical safety issues<br />

The MP4 report allows you to identify critical safety issues such as:<br />

@ Incorrect break<strong>in</strong>g capacity<br />

@ Absence of <strong>in</strong>terlock<strong>in</strong>g devices<br />

@ Inappropriate protection of people<br />

@ Unprotected access to live parts, etc.<br />

<strong>Schneider</strong> <strong>Electric</strong> East Mediterranean s.a.l.<br />

Tabaris, Charles Malek Avenue, Tabaris Centre 1063, 10 th Floor<br />

P.O. Box : 166223 - Beirut, Lebanon<br />

Tel. +961 1 204 502<br />

Fax +961 1 204 458<br />

www.eastmed.schneider-electric.com<br />

Ma<strong>in</strong>tenance Plan<br />

@ A description of <strong>the</strong> level of ma<strong>in</strong>tenance to be performed<br />

@ The stress and reliability levels of critical devices<br />

@ A strategy for <strong>the</strong> ma<strong>in</strong>tenance plan schedule<br />

Modernisation Plan<br />

@ A list of equipment at <strong>the</strong> end of its service life and proposals of<br />

available retrofit solutions<br />

@ Advice on improv<strong>in</strong>g <strong>in</strong>stallation performance<br />

@ Suggestions on how to adapt your <strong>in</strong>stallation to meet your <strong>new</strong><br />

bus<strong>in</strong>ess requirements<br />

Monitor<strong>in</strong>g Plan<br />

@ A predictive approach to anticipate potential device failure<br />

@ Energy quality and availability <strong>in</strong>dicators<br />

@ Opportunities for <strong>energy</strong> sav<strong>in</strong>gs <strong>in</strong> relation to <strong>the</strong> various solutions<br />

deployed<br />

Management Plan<br />

The plan outl<strong>in</strong>es recommendations target<strong>in</strong>g:<br />

@ The safety of people work<strong>in</strong>g on <strong>the</strong> equipment<br />

@ Service contracts with respect to your subcontract<strong>in</strong>g policy<br />

@ Management of spare parts<br />

@ Competency <strong>management</strong> <strong>in</strong>clud<strong>in</strong>g expertise and tra<strong>in</strong><strong>in</strong>g<br />

@ Data <strong>management</strong> through direct access to <strong>the</strong> <strong>Schneider</strong> <strong>Electric</strong><br />

expert system<br />

Cyprus + 357 24 812 649 • customercare.cy@schneider-electric.com<br />

Iraq + 962 6 516 6260 • customercare.iq@schneider-electric.com<br />

Jordan + 962 6 516 6465 • customercare.jo@schneider-electric.com<br />

Lebanon + 961 1 321 645 • customercare.lb@schneider-electric.com<br />

Syria + 963 11 6124799 • customercare.sy@schneider-electric.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!