14.11.2012 Views

new - the global specialist in energy management - Schneider Electric

new - the global specialist in energy management - Schneider Electric

new - the global specialist in energy management - Schneider Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Educational Solutions<br />

Energy Efficiency<br />

Heat<strong>in</strong>g control bench<br />

Teach<strong>in</strong>g objectives<br />

@ To use and program <strong>the</strong> control<br />

functions of a Premium PLC<br />

@ To understand and configure <strong>the</strong> operation<br />

of a control loop<br />

<strong>Electric</strong>al and<br />

mechanical data<br />

@ Power supply:<br />

230 V T / 2000 VA<br />

@ Size (H x W x D) - weight:<br />

1800 x 1000 x 1000 mm - 120 kg<br />

Ma<strong>in</strong> <strong>in</strong>dustries<br />

@ <strong>Electric</strong>al eng<strong>in</strong>eer<strong>in</strong>g<br />

@ Control and monitor<strong>in</strong>g<br />

8www.eastmed.schneider-electric.com<br />

Package description<br />

The heat<strong>in</strong>g control bench is used to study a central heat<strong>in</strong>g system with<br />

control loops.<br />

The operational part represents a reduced central heat<strong>in</strong>g system compris<strong>in</strong>g:<br />

@ a 3-way motorised valve<br />

@ a variable speed pump (circulator)<br />

@ a heat exchanger (fan-cooled heats<strong>in</strong>k).<br />

The control part <strong>in</strong>cludes a Premium PLC which provides all <strong>the</strong> control<br />

operations, an Altivar variable speed drive and all <strong>the</strong> associated electrical<br />

protection elements.<br />

A graphic operator <strong>in</strong>terface term<strong>in</strong>al is used to control and monitor <strong>the</strong> system.<br />

An E<strong>the</strong>rnet connection allows you to connect a computer and control<br />

supervision remotely.<br />

The system is configured to use one of <strong>the</strong> three follow<strong>in</strong>g control loops:<br />

@ PID loop: central heat<strong>in</strong>g with <strong>in</strong>ternal temperature sensor<br />

(act<strong>in</strong>g on <strong>the</strong> water flow)<br />

@ PID loop + servo: central heat<strong>in</strong>g with <strong>in</strong>ternal temperature sensor<br />

(act<strong>in</strong>g on <strong>the</strong> three-way valve)<br />

@ PID loop: central heat<strong>in</strong>g with external temperature sensor and water<br />

ratio (act<strong>in</strong>g on <strong>the</strong> three-way valve).<br />

The system can be disturbed us<strong>in</strong>g a set of three motorised fans of variable<br />

speed.<br />

To order<br />

Close-up view of 3-way valve<br />

MD1AE895PR: heat<strong>in</strong>g control bench