Renovation, retrofit and spare parts solutions<br />

Retrofitt<strong>in</strong>g<br />

competitors’ devices<br />

Medium voltage<br />

Medium-voltage devices can be replaced accord<strong>in</strong>g to <strong>the</strong> retrofit or retrofil pr<strong>in</strong>ciple.<br />

In <strong>the</strong> case of medium-voltage devices manufactured by our competitors, <strong>the</strong> retrofil solution is <strong>the</strong> simplest and fastest method<br />

of replac<strong>in</strong>g a customer’s equipment. We can renovate a customer’s orig<strong>in</strong>al truck and fit it with a <strong>Schneider</strong> <strong>Electric</strong> device,<br />

circuit breaker or contactor.<br />

The power connection elements are ei<strong>the</strong>r renovated or reconditioned.<br />

The devices are <strong>the</strong>n tested for dielectric withstand and overheat<strong>in</strong>g and undergo mechanical tests.<br />

Examples of MV devices<br />

Brand Type Techno Rat<strong>in</strong>g New device<br />

ABB Contactor C1 Air 250 A 7.2 kV Contactor<br />

Rollarc R400<br />

ALSTOM Circuit breaker<br />

CB411<br />

DELLE Circuit breaker<br />

HG3<br />

Low voltage<br />

The retrofit pr<strong>in</strong>ciple can be used to replace low-voltage devices manufactured by our competitors.<br />

Both <strong>the</strong> device and its truck can be replaced with a complete <strong>Schneider</strong> <strong>Electric</strong> device and <strong>the</strong><br />

auxiliaries connections recreated.<br />

With <strong>the</strong> retrofit solution, as <strong>the</strong> devices have already been tested,<br />

only a power connection overheat<strong>in</strong>g test is carried out.<br />

Oil 2900 A 7.2 kV Circuit breaker<br />

LF3<br />

Oil 2500 A 7.2 kV Circuit breaker<br />

LF3<br />

BBC Circuit breaker Oil 630 A 7.2 kV Circuit breaker<br />

LF1<br />

BBC Circuit breaker Oil 2000 A 7.2 kV Circuit breaker<br />

LF2<br />

BBC Circuit breaker<br />

W-RM/W-RG<br />

Calor Emag Circuit breaker<br />

ODM3<br />

Calor Emag Circuit breaker<br />

ZE4WL<br />

Oil 1250 A 17.5 kV Circuit breaker<br />

DV2<br />

Oil 1250 A 13.8 kV Circuit breaker<br />

LF2<br />

Oil 1250 A 13.8 kV Circuit breaker<br />

LF2<br />

CEM Contactor GF SF6 250 A 7.2 kV Contactor<br />

Rollarc R400<br />

SIEMENS Circuit breaker Oil 630 A 7.2 kV Circuit breaker<br />

DV2<br />

Examples of LV devices<br />

Brand Type Rat<strong>in</strong>g New device<br />

UNELEC CNP 1000 1000 A 4 P Masterpact NT 10 H1<br />

UNELEC CS 1250 1250 A 3 P Masterpact NW 12 H1<br />

UNELEC CS 2500 2500 A 3 P Masterpact NW 25 H1