Modernization Presentation of the offer Introduction www.eastmed.schneider-electric.com Today, the productivity, operating safety, continuity of service and availability requirements of installations are such that at all levels of a company, the quest for high performance is a major consideration. The experience gained by Schneider Electric in carrying out more than 5000 medium-voltage retrofits on Belledonne, Taillefer, Fluair and Vercors cubicles and more than 3000 low-voltage retrofits on T140, T12 and Masterbloc switchboards has enabled us to acquire the expertise and know-how required to help you secure the loyalty of your customers. According to the equipment concerned, Schneider Electric offers different types of services, including: @ Supplying spare parts, @ Modifying cubicles, @ Replacing protective devices, @ Replacing original devices with latest-generation devices. There are various ways of replacing old devices. The most usual methods are: Retrofit: the original circuit breaker and its truck are replaced @ The connection interfaces (power and low voltage) are adapted for use on the original cubicle. @ The new circuit breaker is fitted with the new interfaces. @ The solution is tested mechanically with the mounting jig. Retrofil: the original truck is retained and fitted with a new circuit breaker @ The original truck is renovated. @ The power interfaces are either retained and renovated or they are recreated. @ The new circuit breaker is adapted for mounting on the original truck. @ The solution is tested mechanically with the mounting jig. Schneider Electric can also implement these solutions with devices manufactured by its competitors (Alstom, Calor Emag, ABB, ASEA, BBC, UNELEC, AREVA). Many retrofitted devices are in use worldwide. Schneider Electric is actively working to improve delivery times and optimise the costs of retrofit solutions in order to provide you with constant support and help in ensuring customer satisfaction. We pay particular attention to quality, which is our major consideration.

Modernization Presentation of the offer Renovations solutions www.eastmed.schneider-electric.com Scope of the offer Switchboard renovation @ Progressive replacement without modification of customers’ equipment: renovation of medium and low voltage switchgear, kits for improving equipment. @ Complete replacement or addition of cubicles by extension: insertion of cubicles into the switchboard with connection ducts, addition at the end of the switchboard of cubicles identical to the initial cubicle, in accordance with floor space constraints. Switchgear renovation Replacement of old medium and low voltage switchgear and protection devices by retrofit solutions. Supply of spare parts Ensure the supply of spare parts for equipment that is no longer commercialized by the equipment-producing departments. Cost-effective solutions to fit your needs @ No break in continuity of service, @ No added civil engineering work, @ No modification of your equipment, @ Operating constraints taken into account, @ Progressive renovation to fit your budget. Validated and tested solutions @ Manufacturer’s warranty on renovated equipment, @ Factory-validated and tested equipment. New solutions @ Compliant with the standards in effect, @ Integration of new-generation products, @ Evolving device technology.

Modernization<br />

Presentation of <strong>the</strong> offer<br />

Introduction<br />

www.eastmed.schneider-electric.com<br />

Today, <strong>the</strong> productivity, operat<strong>in</strong>g safety, cont<strong>in</strong>uity of service<br />

and availability requirements of <strong>in</strong>stallations are such that at all<br />

levels of a company, <strong>the</strong> quest for high performance is a major<br />

consideration.<br />

The experience ga<strong>in</strong>ed by <strong>Schneider</strong> <strong>Electric</strong> <strong>in</strong> carry<strong>in</strong>g out more than 5000 medium-voltage<br />

retrofits on Belledonne, Taillefer, Fluair and Vercors cubicles and more than 3000 low-voltage<br />

retrofits on T140, T12 and Masterbloc switchboards has enabled us to acquire <strong>the</strong> expertise<br />

and know-how required to help you secure <strong>the</strong> loyalty of your customers.<br />

Accord<strong>in</strong>g to <strong>the</strong> equipment concerned, <strong>Schneider</strong> <strong>Electric</strong> offers different types of services,<br />

<strong>in</strong>clud<strong>in</strong>g:<br />

@ Supply<strong>in</strong>g spare parts,<br />

@ Modify<strong>in</strong>g cubicles,<br />

@ Replac<strong>in</strong>g protective devices,<br />

@ Replac<strong>in</strong>g orig<strong>in</strong>al devices with latest-generation devices.<br />

There are various ways of replac<strong>in</strong>g old devices. The most usual methods are:<br />

Retrofit: <strong>the</strong> orig<strong>in</strong>al circuit breaker and its truck are replaced<br />

@ The connection <strong>in</strong>terfaces (power and low voltage) are adapted for use on <strong>the</strong> orig<strong>in</strong>al cubicle.<br />

@ The <strong>new</strong> circuit breaker is fitted with <strong>the</strong> <strong>new</strong> <strong>in</strong>terfaces.<br />

@ The solution is tested mechanically with <strong>the</strong> mount<strong>in</strong>g jig.<br />

Retrofil: <strong>the</strong> orig<strong>in</strong>al truck is reta<strong>in</strong>ed and fitted with a <strong>new</strong> circuit<br />

breaker<br />

@ The orig<strong>in</strong>al truck is renovated.<br />

@ The power <strong>in</strong>terfaces are ei<strong>the</strong>r reta<strong>in</strong>ed and renovated or <strong>the</strong>y are recreated.<br />

@ The <strong>new</strong> circuit breaker is adapted for mount<strong>in</strong>g on <strong>the</strong> orig<strong>in</strong>al truck.<br />

@ The solution is tested mechanically with <strong>the</strong> mount<strong>in</strong>g jig.<br />

<strong>Schneider</strong> <strong>Electric</strong> can also implement <strong>the</strong>se solutions with devices manufactured by its<br />

competitors (Alstom, Calor Emag, ABB, ASEA, BBC, UNELEC, AREVA).<br />

Many retrofitted devices are <strong>in</strong> use worldwide.<br />

<strong>Schneider</strong> <strong>Electric</strong> is actively work<strong>in</strong>g to improve delivery times and optimise <strong>the</strong> costs of<br />

retrofit solutions <strong>in</strong> order to provide you with constant support and help <strong>in</strong> ensur<strong>in</strong>g customer<br />

satisfaction.<br />

We pay particular attention to quality, which is our major consideration.