14.11.2012 Views

new - the global specialist in energy management - Schneider Electric

new - the global specialist in energy management - Schneider Electric

new - the global specialist in energy management - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Asset Management Program<br />

Medium Voltage Spare Parts<br />

Power factor<br />

correction<br />

Instrument<br />

transformer<br />

Fuse<br />

Switch /<br />

disconnector<br />

Contactor<br />

Circuit breaker<br />

Protection<br />

CP 200<br />

series<br />

Propivar<br />

CT, VT<br />

LPCT<br />

CT, VT<br />

MGK<br />

Tepefuse,<br />

Fusarc<br />

CF<br />

Solefuse<br />

Fusarc<br />

CF<br />

LBSkit<br />

CTV1<br />

Rollarc<br />

GI-E<br />

Evolis 24 kV<br />

Evolis HP<br />

Evolis<br />

17.5 kV<br />

SF2<br />

SF F400<br />

SF1, SFset<br />

LFP<br />

LF<br />

Sepam<br />

series 80<br />

Sepam<br />

series 20<br />

series 40<br />

Sepam<br />

series 10<br />

Multifunction protection unit<br />

for all voltage levels<br />

RATED VOLTAGE<br />

Application<br />

substation<br />

busbar<br />

transformer<br />

motor<br />

generator<br />

capacitor<br />

14400 kvar<br />

600 kvar<br />

2500 A<br />

2500 A<br />

5000 A<br />

250 A<br />

2.5 A<br />

125 A<br />

250 A<br />

1250 A<br />

250 A<br />

400 A<br />

3150 A<br />

1250 A<br />

2500 A<br />

3150 A<br />

2500 A<br />

3150 A 2500 A<br />

3150 A 1250 A<br />

1250 A<br />

MAX. RATED CURRENT<br />

3150 A 5000 A<br />

Protocols<br />

Modbus, IEC 60870-5-103, DNP3, IEC 61850<br />

31.5 kA<br />

50 kA<br />

40 kA<br />

50 kA<br />

l1 l1 l1 l1<br />

63 kA 50 kA 63 kA 50 kA<br />

25 kA<br />

8 kA<br />

8 kA<br />

10 kA<br />

31.5 kA<br />

31.5 kA 25 kA<br />

50 kA<br />

40 kA<br />

40 kA 31.5 kA<br />

MAX. RATED SHORT CIRCUIT CURRENT<br />

50 kA 40 kA 50 kA 31.5 kA 25 kA 40 kA 31.5 kA<br />

vacuum /<br />

SF6<br />

"all film"<br />

with or<br />

without<br />

<strong>in</strong>ternal<br />

fuses<br />

dry<br />

dry<br />

dry<br />

SF6<br />

vacuum<br />

SF6<br />

SF6<br />

vacuum<br />

vacuum<br />

vacuum<br />

SF6<br />

SF6<br />

SF6<br />

SF6<br />

SF6<br />

digital<br />

Power factor<br />

correction<br />

and harmonic<br />

filter<strong>in</strong>g on<br />

MV networks<br />

Power factor<br />

correction on<br />

MV networks<br />

or devices<br />

Outdoor<br />

Current<br />

Transformer<br />

and<br />

Voltage<br />

Transformer<br />

Fixed or<br />

automatic capacitor<br />

banks<br />

for motor,<br />

substation,<br />

or <strong>global</strong><br />

distribution<br />

R<strong>in</strong>g<br />

type and<br />

medium<br />

voltage<br />

Low<br />

Power<br />

Current<br />

Transformer<br />

(LPCT)<br />

R<strong>in</strong>g<br />

type and<br />

medium<br />

voltage<br />

Current<br />

Transformer,<br />

Voltage<br />

Transformer<br />

Standard<br />

AFNOR<br />

Standards<br />

IEC, DIN,<br />

UTE<br />

Standards<br />

IEC, UTE<br />

Standards<br />

DIN, IEC<br />

Indoor load break<br />

switch (630 A),<br />

disconnector and<br />

accessories<br />

Vacuum<br />

withdrawable<br />

contactor<br />

Fixed and withdrawable<br />

contactor with<br />

magnetic hold<strong>in</strong>g or<br />

mechanical latch<strong>in</strong>g<br />

Outdoor fixed<br />

circuit breaker<br />

Fixed circuit<br />

breaker<br />

Fixed<br />

and withdrawable<br />

circuit breaker<br />

With drawable<br />

circuit breaker<br />

Fixed<br />

and withdrawable<br />

circuit breaker<br />

Fixed circuit<br />

breaker<br />

Withdrawable<br />

circuit breaker<br />

Fixed circuit<br />

breaker<br />

Fixed circuit<br />

breaker<br />

high power<br />

version<br />

for power plant<br />

Fixed and<br />

withdrawable<br />

circuit breaker<br />

Multifunction unit<br />

compact and<br />

flexible<br />

for all current<br />

applications<br />

Fuse for Motor<br />

measurement protection<br />

transformer fuse range<br />

protection up<br />

to 24 kV<br />

(Tepefuse)<br />

and up to<br />

36 kV<br />

(Fusarc CF)<br />

Fuses for<br />

distribution<br />

transformer<br />

from 3.6 kV to<br />

36 kV<br />

Side<br />

mounted<br />

Front<br />

mounted<br />

Front mounted<br />

Front mounted<br />

Overcurrent and<br />

earth-fault relay<br />

for basic protection<br />

of feeders<br />

and distribution<br />

transformers<br />

Front or side<br />

mounted<br />

mechanism<br />

Multifunction unit<br />

<strong>in</strong>telligent and<br />

flexible<br />

for custom<br />

applications<br />

(Logipam<br />

software)<br />

Thermal<br />

protection<br />

<strong>in</strong>cluded<br />

Indoor or<br />

outdoor<br />

<strong>in</strong>stallation<br />

VIP<br />

<strong>in</strong>tegrated trip<br />

unit (with out<br />

auxilary<br />

power supply)<br />

<strong>in</strong> Evoset up<br />

to 20 kA<br />

VIP <strong>in</strong>tegrated<br />

trip unit (without<br />

auxiliary power<br />

supply) <strong>in</strong> SFset<br />

up to 24 kV<br />

www.eastmed.schneider-electric.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!