29.01.2015 Views

MagPro coils

MagPro coils

MagPro coils

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MagPro</strong> <strong>coils</strong><br />

Versatility in Magnetic Stimulation<br />

V<br />

MagVenture<br />

For Clinical and Research use


Selection Criteria for Magnetic Stimulating Coils<br />

2<br />

Large, or Small Coils<br />

– circular or figure of 8<br />

Large <strong>coils</strong> provide a high penetration depth, but are not<br />

very focused. The small <strong>coils</strong> are more focused, but have a<br />

relatively shallow penetration depth. Thus there is an inverse<br />

relation between penetration depth and focus.The <strong>coils</strong><br />

come in many sizes and shapes. The two most commonly<br />

used <strong>coils</strong> are the circular shaped coil and the butterfly<br />

shaped coil also known as the “figure of 8” coil.<br />

Circular or Parabolic Coils<br />

Butterfly Coils<br />

The Butterfly <strong>coils</strong> are more focused in comparison with the<br />

circular <strong>coils</strong>. The two windings are placed side-by-side or<br />

overlapping, enabling the coil to stimulate structures with<br />

focus right under its center. The butterfly coil is useful in<br />

focused stimulation.<br />

List of MagVentures standard <strong>coils</strong> with basic<br />

facts. More detailed informations at<br />

www.magventure.com<br />

When applying the circular or parabolic coil, the induced<br />

current in the tissue occurs under the windings. A fairly large<br />

area of body tissue will be stimulated.<br />

The circular or parabolic coil may be positioned<br />

conveniently over many parts of the body, and usually serves<br />

well as a “general purpose coil”.<br />

Model<br />

Type<br />

Coil Winding<br />

Diameter<br />

Magnetic<br />

Gradient<br />

Number of<br />

pulses before<br />

warm-up<br />

Applications<br />

MC-125 Circular Coil 114 mm 41 kT/s 450 pulses General Purpose,<br />

Phrenic nerve roots,<br />

Motor Cortex<br />

C-100 Circular Coil<br />

Built-in amplitude<br />

control<br />

110 mm 35 kT/s 400 pulses General Purpose,<br />

Phrenic nerve roots,<br />

Motor Cortex<br />

MMC-140 Parabolic Coil 120 mm 33 kT/s 650 pulses General Purpose,<br />

Motor Cortex,<br />

Deep-lying nerves<br />

MMC-140-II<br />

Parabolic Coil<br />

Built-in amplitude<br />

control<br />

126 mm 33 kT/s 650 pulses General Purpose,<br />

Motor Cortex,<br />

Deep-lying nerves<br />

gVg<br />

MagVenture


3<br />

Model<br />

Type<br />

Coil Winding<br />

Diameter<br />

Magnetic<br />

Gradient<br />

Number of<br />

pulses before<br />

warm-up<br />

Applications<br />

MC-B35 2 x 45 mm 50 kT/s 75 pulses Peripheral nerves<br />

High focus stimulation<br />

Low penetration<br />

depth<br />

MC-B70<br />

Figure-of-8 Coil<br />

Bend outer windings<br />

provide +10% power<br />

2 x 97 mm 31 kT/s 400 pulses Foc. Stimulations,<br />

Deep-lying nerves,<br />

Motor Cortex,<br />

Peripheral nerves<br />

C-B60<br />

Figure-of-8 Coil<br />

Built-in amplitude<br />

control<br />

2 x 75 mm 35 kT/s 350 pulses Foc. Stimulations,<br />

Motor Cortex,<br />

Peripheral nerves<br />

D-B80<br />

Figure-of-8 Coil<br />

120° angled<br />

2 x 80 mm 31 kT/s 350 pulses Foc. Stimulations,<br />

Motor Cortex,<br />

Peripheral nerves<br />

MC-B65-HO<br />

2 : 2m cable<br />

8 : 8m cable<br />

Figure-of-8 Coil<br />

Orthogonal handle<br />

2 x 75 mm 35 kT/s 350 pulses Foc. Stimulations,<br />

Motor Cortex,<br />

Peripheral nerves<br />

RT-120<br />

Elliptic coil (racetrack<br />

coil)<br />

Inner loop<br />

ø30x110mm<br />

Outer loop<br />

ø80x160mm<br />

31 kT/s 1500 pulses General Purpose<br />

Bigger muscles<br />

Spinal nerves<br />

RT-120-II<br />

Elliptic coil (racetrack<br />

coil) with built in<br />

amplitude control.<br />

Inner loop<br />

ø30x110mm<br />

Outer loop<br />

ø80x160mm<br />

31 kT/s 1500 pulses General Purpose<br />

Bigger muscles<br />

Spinal nerves<br />

MagVenture


4<br />

F <strong>coils</strong> – Static cooled <strong>coils</strong><br />

Static cooled <strong>coils</strong>. To prevent fast overheating during use<br />

we developed the static cooled F-series of <strong>coils</strong>. The fluid<br />

absorbes dissipated energy thus enabling more stimulis.<br />

Model<br />

Type<br />

Coil Winding<br />

Diameter<br />

Magnetic<br />

Gradient<br />

Number of<br />

pulses before<br />

warm-up<br />

Applications<br />

MCF-75<br />

Small circular Coil<br />

Static fluid Cooling<br />

65 mm 43 kT/s 500 pulses Peripheral nerves,<br />

Motor Cortex<br />

MCF-125<br />

Standard circular Coil<br />

Static fluid Cooling<br />

120 mm 34 kT/s 2000 pulses Train stimulation,<br />

Brain tissue,<br />

Deep-lying nerves<br />

MCF-B65<br />

Figure-of-8 Coil<br />

Static fluid Cooling<br />

2 x 75 mm 32 kT/s 2000 pulses Train stimulation,<br />

Brain tissue,<br />

Deep-lying nerves<br />

Dynamic cooled <strong>coils</strong> – Coils with external cooling<br />

When the highest number of stimulations are required dynamic<br />

cooling is required.<br />

The cool unit in combination with the Cool-B65 coil are<br />

the solution if a long duration and high stimulation output is<br />

required.<br />

Cool unit required for<br />

MagVenture Cool-B65 coil.<br />

Model<br />

Type<br />

Coil Winding<br />

Diameter<br />

Magnetic<br />

Gradient<br />

Number of<br />

pulses before<br />

warm-up<br />

Applications<br />

Cool-B65<br />

Figure-of-8 Coil<br />

Dynamic fluid Cooling<br />

2 x 75 mm 36 kT/s 20000 pulses Train protocols,<br />

Long train stimulation,<br />

Brain tissue,<br />

Deep-lying nerves<br />

V<br />

MagVenture


5<br />

Placebo <strong>coils</strong><br />

MagVenture placebo <strong>coils</strong> are geometrical identical with the<br />

corresponding normal <strong>coils</strong>.<br />

Placebo coil are intended for blind testing and have considerable<br />

lower magnetic fields than the normal <strong>coils</strong>.<br />

Model<br />

Type<br />

Coil Winding<br />

Diameter<br />

Magnetic<br />

Gradient<br />

Number of<br />

pulses before<br />

warm-up<br />

Applications<br />

MC-P-B70<br />

Figure-of-8 Coil<br />

Placebo Coil<br />

2 x 100 mm Magnetic<br />

field attenuation<br />

> 80%<br />

400 pulses Placebo version of<br />

MC-B70<br />

MC-P-B65<br />

Figure-of-8 Coil<br />

Placebo Coil<br />

2 x 75 mm Magnetic<br />

field attenuation<br />

> 80%<br />

1600 pulses Placebo version of<br />

MCF-B65<br />

Special <strong>coils</strong><br />

MagVenture develops special <strong>coils</strong> for special purposes. Many<br />

<strong>coils</strong> have been developed. Examples MRi-B88 for use in MR<br />

scanners and the Twin Coil for Magnetic Seizure Therapy<br />

(together with the special <strong>MagPro</strong> MST stimulator)<br />

Custom designed <strong>coils</strong><br />

Besides our standard <strong>coils</strong> we manufactures custom designed<br />

<strong>coils</strong> based on specifications from our customers.<br />

gVg<br />

MagVenture


6<br />

General coil features.<br />

All <strong>coils</strong> are designed for use with Magpro R30, X100, R30<br />

with option, X100 with option and R100.<br />

Coils with build in power control in the coil handle and<br />

trigger button in the handle can also be used with a <strong>MagPro</strong><br />

Compact. (coil C-100, C-B60, RT 120-II and MMC-140-II)<br />

Coils without built in power control and trigger button<br />

requires the coil converter when connected to a <strong>MagPro</strong><br />

Compact.<br />

Additional accessories<br />

Accessories such as Remote control, MEP monitor, Cable for<br />

external trig, Flexible arm, Flight case for the <strong>MagPro</strong>, Mag-<br />

Probe, 110/230V power supply for the <strong>MagPro</strong> etc. are also<br />

supplied by MagVenture. Please see MagVenture on<br />

www.magventure.com for further details.<br />

North America<br />

Please note that not all <strong>coils</strong> are cleared for sale by FDA in the US.<br />

For further details of which are cleared in the US, please contact local MagVenture distributor<br />

#5426 www.danske-ideselskab.dk<br />

VERSATILITY IN MAGNETIC STIMULATION<br />

MagVenture<br />

Lucernemarken 15 · DK-3520 Farum · Denmark<br />

Phone: +45 4499 8444 · Fax: +45 4439 0449<br />

E-mail: info@magventure.com · www.magventure.com