Section 10: POSTPROCESSORS<br />

10.6.4 Timeseries File(s)<br />

CALPOST can gener<strong>at</strong>e a set <strong>of</strong> optional timeseries files for the concentr<strong>at</strong>ion, deposition flux, or<br />

extinction coefficient identified in the CALPOST control file, <strong>at</strong> each receptor selected, for each<br />

averaging time selected. Each averaging time is placed in a separ<strong>at</strong>e file, so there may be as many as five<br />

timeseries files gener<strong>at</strong>ed (1-period, 1-hour, 3-hour, 24-hour and N-user averages). <strong>The</strong> period covered<br />

by the timeseries is controlled by the selected day option as well as the period processed. No timeseries<br />

output is gener<strong>at</strong>ed if no days are selected. All averages in the period processed are written to the<br />

timeseries file(s) if all days are selected.<br />

For a given time (e.g, the 3-hour period beginning <strong>at</strong> 0900 on Julian day 310), the current averages for all<br />

selected receptors are written as a single "record". <strong>The</strong> length <strong>of</strong> the record grows as the number <strong>of</strong><br />

receptors increases. <strong>The</strong>refore, the timeseries option should be used with a manageable subset <strong>of</strong> the<br />

receptors contained in the CALPUFF simul<strong>at</strong>ion.<br />

<strong>The</strong> form<strong>at</strong> <strong>of</strong> the timeseries file is described in <strong>Table</strong> 10-25. <strong>The</strong> file contains a number <strong>of</strong> header<br />

records th<strong>at</strong> identify the parameter th<strong>at</strong> is reported, its units and averaging time, and the number <strong>of</strong><br />

receptors included. <strong>The</strong> loc<strong>at</strong>ion <strong>of</strong> each receptor is provided. D<strong>at</strong>a records follow, with a single record<br />

for each time period. An example timeseries file for 30-minute averages <strong>of</strong> SO 2 <strong>at</strong> one gridded receptor<br />

for a single 4-hour period is shown in <strong>Table</strong> 10-26.<br />

10-85