Section 9: CALPUFF<br />

BDOWN real Building downwash flag<br />

0. = building downwash not modeled,<br />

1. = building downwash modeled<br />

EMS real array Emission r<strong>at</strong>e <strong>of</strong> each modeled species<br />

Note: "NSPEC" values must be entered<br />

-<br />

-<br />

<strong>Table</strong> 9-3 (Continued)<br />

CALPUFF Control File Inputs - Input <strong>Group</strong> 13<br />

Point Source Parameters<br />

Variable Type Description Default Value<br />

(Optional Variables for Input <strong>Group</strong> 13b)<br />

SIGMAYI real Initial sigma-y (m) associ<strong>at</strong>ed with the release from this<br />

source<br />

SIGMAZI real Initial sigma-z (m) associ<strong>at</strong>ed with the release from this<br />

source<br />

FMFAC real is a vertical momentum flux factor (0. or 1.0) used to<br />

represent the effect <strong>of</strong> rain-caps or other physical<br />

configur<strong>at</strong>ions th<strong>at</strong> reduce momentum rise associ<strong>at</strong>ed with<br />

the actual exit velocity. FMFAC=1 is full momentum (no<br />

obstruction).<br />

0.0<br />

-<br />

0.0<br />

1.0<br />

ZPLTFM real is the pl<strong>at</strong>form height (m) for sources influenced by an<br />

0.0<br />

isol<strong>at</strong>ed structure th<strong>at</strong> has a significant open area between<br />

the surface and the bulk <strong>of</strong> the structure<br />

<strong>The</strong> variables in Input <strong>Group</strong> 13b are entered for each <strong>of</strong> the "NPT1" point sources. <strong>The</strong> d<strong>at</strong>a for each<br />

source is tre<strong>at</strong>ed as a separ<strong>at</strong>e input subgroup, and therefore, must end with an input group termin<strong>at</strong>or<br />

(i.e., !END!). Note th<strong>at</strong> the source number is an optional user comment which is outside <strong>of</strong> the delimiter<br />

containing the required source d<strong>at</strong>a. <strong>The</strong> d<strong>at</strong>a for each source must follow an opening delimiter and "X=".<br />

<strong>The</strong> d<strong>at</strong>a for each source is followed by a closing delimiter and an input group termin<strong>at</strong>or.<br />

<strong>The</strong> first two optional variables may be provided for point sources th<strong>at</strong> have a characteristic distribution<br />

much like volume sources. <strong>The</strong> values are entered in order between delimiters, following “SIGYZI=”.<br />

<strong>The</strong> third optional variable is typically used for sources with rain-h<strong>at</strong>s th<strong>at</strong> elimin<strong>at</strong>e the initial vertical<br />

momentum <strong>of</strong> the release. <strong>The</strong>se records must be placed before the input group termin<strong>at</strong>es (i.e., !END!)<br />

for the point source.<br />