Section 9: CALPUFF *ZISPLIT real Split is allowed only if last hour's mixing height (m) exceeds this minimum value *ROLDMAX real Split is allowed only if ratio of last hour's mixing ht to the maximum mixing ht experienced by the puff is less than this maximum value (this postpones a split until a nocturnal layer develops) 100.0 0.25 (Horizontal Puff-Spliting Control Variables *) *NSPLITH integer Number of puffs that result every time a puff is split - nsplith=5 means that 1 puff splits into 5 *SYSPLITH integer Minimum sigma-y (Grid Cells Units) of puff before it may be split *SHSPLITH integer Minimum puff elongation rate (SYSPLITH/hr) due to wind shear, before it may be split Table 9-3 (Continued) CALPUFF Control File Inputs - Input Group 12 Dispersion and Computational Parameters 5 1.0 2.0 Variable Type Description Default Value *CNSPLITH (mxspec) integer array Minimum concentration (g/m 3 ) of each species in puff before it may be split. Enter array of NSPEC values; if a single value is entered, it will be used for ALL species 1.0E-07 (Integration Control Variables *) *EPSSLUG real Fractional convergence criterion for numerical slug sampling integration *EPSAREA real Fractional convergence criterion for numerical area source integration *DSRISE real Trajectory step length (m) for numerical rise integration. 1.0E-04 1.0E-06 1.0 (Boundary Condition Puff Control Variables *) *HTMINBC real Minimum height (m) to which BC puffs are mixed as they are emitted (MBCON=2 ONLY). Actual height is reset to the current mixing height at the release point if greater than this minimum. 500. *RSAMPBC real Search radius (km) about a receptor for sampling nearest BC puff. BC puffs are typically emitted with a spacing of one grid cell length, so the search radius should be greater than DGRIDKM. 10. 9-90
Section 9: CALPUFF *MDEPBC integer Near-Surface depletion adjustment to concentration profile used when sampling BC puffs 1 0 = Concentration is NOT adjusted for depletion 1 = Adjust Concentration for depletion 9-91
- Page 475 and 476: Section 9: CALPUFF -------- a Data
- Page 477 and 478: Section 9: CALPUFF Number of buoyan
- Page 479 and 480: Section 9: CALPUFF -------- a Data
- Page 481 and 482: Section 9: CALPUFF Number of non-gr
- Page 483 and 484: Section 9: CALPUFF 9-47
- Page 485 and 486: Section 9: CALPUFF Table 9-3 (Conti
- Page 487 and 488: Section 9: CALPUFF Table 9-3 (Conti
- Page 489 and 490: Section 9: CALPUFF Table 9-3 (Conti
- Page 491 and 492: Section 9: CALPUFF IOUTU IOVERS int
- Page 493 and 494: Section 9: CALPUFF MSHEAR integer V
- Page 495 and 496: Section 9: CALPUFF MDISP integer Me
- Page 497 and 498: Section 9: CALPUFF MPDF integer Pro
- Page 499 and 500: Section 9: CALPUFF 9-63
- Page 501 and 502: Section 9: CALPUFF Table 9-3 (Conti
- Page 503 and 504: Section 9: CALPUFF Table 9-3 (Conti
- Page 505 and 506: Section 9: CALPUFF 9-69
- Page 507 and 508: Section 9: CALPUFF IMFLX integer Co
- Page 509 and 510: Section 9: CALPUFF IPRTU integer Co
- Page 511 and 512: Section 9: CALPUFF Table 9-3 (Conti
- Page 513 and 514: Section 9: CALPUFF Table 9-3 (Conti
- Page 515 and 516: Section 9: CALPUFF Table 9-3 (Conti
- Page 517 and 518: Section 9: CALPUFF Table 9-3 (Conti
- Page 519 and 520: Section 9: CALPUFF BCKNH3(12) real
- Page 521 and 522: Section 9: CALPUFF Table 9-3 (Conti
- Page 523 and 524: Section 9: CALPUFF Table 9-3 (Conti
- Page 525: Section 9: CALPUFF CDIV(2) real Div
- Page 529 and 530: Section 9: CALPUFF BDOWN real Build
- Page 531 and 532: Section 9: CALPUFF Table 9-3 (Conti
- Page 533 and 534: Section 9: CALPUFF Table 9-3 (Conti
- Page 535 and 536: Section 9: CALPUFF Table 9-3 (Conti
- Page 537 and 538: Section 9: CALPUFF source is treate
- Page 539 and 540: Section 9: CALPUFF Table 9-3 (Conti
- Page 541 and 542: Section 9: CALPUFF (i.e., !END!). I
- Page 543 and 544: Section 9: CALPUFF Table 9-3 (Conti
- Page 545 and 546: Section 9: CALPUFF Table 9-3 (Conti
- Page 547 and 548: Section 9: CALPUFF (i.e., !END!). I
- Page 549 and 550: Section 9: CALPUFF Table 9-3 (Conti
- Page 551 and 552: Section 9: CALPUFF Table 9-3 (Conti
- Page 553 and 554: Section 9: CALPUFF terminator (i.e.
- Page 555 and 556: Section 9: CALPUFF Table 9-3 (Concl
- Page 557 and 558: Section 9: CALPUFF 9.2 Meteorologic
- Page 559 and 560: Section 9: CALPUFF if(nssta.ge.1)th
- Page 561 and 562: Section 9: CALPUFF Table 9-4: CALME
- Page 563 and 564: Section 9: CALPUFF Table 9-4 (Conti
- Page 565 and 566: Section 9: CALPUFF Table 9-4 (Conti
- Page 567 and 568: Section 9: CALPUFF Table 9-4 (Concl
- Page 569 and 570: Section 9: CALPUFF 4 b 6 ZTEMP real
- Page 571 and 572: Section 9: CALPUFF 9 6 WSTAR real a
- Page 573 and 574: Section 9: CALPUFF 14 6 IRH integer
- Page 575 and 576: Section 9: CALPUFF variable dispers
Section 9: CALPUFF<br />
*MDEPBC integer Near-Surface depletion adjustment to concentr<strong>at</strong>ion<br />
pr<strong>of</strong>ile used when sampling BC puffs<br />
1<br />
0 = Concentr<strong>at</strong>ion is NOT adjusted for depletion<br />
1 = Adjust Concentr<strong>at</strong>ion for depletion<br />
9-91