Section 8: CALMET Model Files<br />

<strong>Table</strong> 8-4 (Continued)<br />

Input <strong>Group</strong> 5 - Wind Field Options and Parameters<br />

Variable Type Description Default Value<br />

IDIOPT2 integer Control variable for domain-averaged<br />

temper<strong>at</strong>ure lapse r<strong>at</strong>e. (0=compute internally<br />

from upper air d<strong>at</strong>a, 1=read preprocessed values<br />

from the file DIAG.DAT.)<br />

IUPT integer Upper air st<strong>at</strong>ion number (between 1 and<br />

NUSTA) used to compute the domain-scale<br />

temper<strong>at</strong>ure lapse r<strong>at</strong>e for the diagnostic wind<br />

field module<br />

ZUPT real Depth (m) through which the domain-scale<br />

temper<strong>at</strong>ure lapse r<strong>at</strong>e is computed<br />

IDIOPT3 integer Control variable for initial-guess wind<br />

components. (0=compute internally from upper<br />

air, 1=read preprocessed values from the file<br />

DIAG.DAT.)<br />

IUPWND integer Upper air st<strong>at</strong>ion number used to compute the<br />

initial-guess wind components for the diagnostic<br />

wind field module. Either specify one st<strong>at</strong>ion<br />

from 1 to nusta or specify -1 indic<strong>at</strong>ing the use <strong>of</strong><br />

1/r 2 interpol<strong>at</strong>ion to gener<strong>at</strong>e a sp<strong>at</strong>ially-variable<br />

initial guess field.<br />

0<br />

-<br />

200.<br />

0<br />

-1<br />

(Input <strong>Group</strong> 5 Continued)<br />