Section 3: READ62 Upper Air Preprocessor<br />

<strong>Table</strong> 3-3 (continued)<br />

Sample READ62 Control File (READ62.INP)<br />

--- Processing Options ---<br />

Top pressure (mb) level for which d<strong>at</strong>a are extracted (e.g., 850 mb,<br />

700 mb, 500 mb, etc.). Pressure level must correspond to a height<br />

th<strong>at</strong> equals or exceeds the top <strong>of</strong> the CALMET modeling domain, or<br />

else CALMET will stop with an error message.<br />

(PSTOP) Default: 700. ! PSTOP = 500 !<br />

Missing d<strong>at</strong>a control options to determine when a sounding level<br />

is rejected, and when an incomplete sounding level is written to<br />

the UP.DAT file with missing value indic<strong>at</strong>ors. <strong>The</strong> missing value<br />

indic<strong>at</strong>ors are:<br />

Height = 9999.<br />

Temper<strong>at</strong>ure = 999.9<br />

Wind Direction = 999<br />

Wind Speed = 999 (999.0)<br />

Elimin<strong>at</strong>e level if <strong>at</strong> least one <strong>of</strong> the following is missing<br />

(LHT) Height Default: F ! LHT = F !<br />

(LTEMP) Temper<strong>at</strong>ure Default: F ! LTEMP = F !<br />

(LWD) Wind Direction Default: F ! LWD = F !<br />

(LWS) Wind Speed Default: F ! LWS = F !<br />

Sounding repair options to autom<strong>at</strong>ically fix-up certain deficiencies<br />

identified in the sounding d<strong>at</strong>a. Any deficiencies not addressed will<br />

be identified in the UP.DAT output file and must be addressed by the<br />

user before th<strong>at</strong> file can be used in CALMET. Note th<strong>at</strong> the repair<br />

options selected will be applied before any sounding replacement is<br />

done (soundings are replaced using the SUBSOUND.DAT file only if the<br />

ISUB variable is not zero).<br />

(1) Extrapol<strong>at</strong>ion to extend missing pr<strong>of</strong>ile d<strong>at</strong>a to PSTOP pressure level<br />

- Wind speed and direction are constant with height<br />

- Temper<strong>at</strong>ure gradient is constant with height<br />

- Valid d<strong>at</strong>a must exist <strong>at</strong> heights as gre<strong>at</strong> as PVTOP (mb) pressure level<br />

(LXTOP) Default: F ! LXTOP = F !<br />

(PVTOP) Default: 850. ! PVTOP = 850 !<br />

(2) Extrapol<strong>at</strong>ion to extend missing pr<strong>of</strong>ile d<strong>at</strong>a to surface<br />

- Wind direction is constant with height<br />

- Wind speed is set with first valid speed, extrapol<strong>at</strong>ed to 10m<br />

using the neutral power law<br />

- Valid d<strong>at</strong>a must exist within first ZVSFC (m) <strong>of</strong> the surface<br />

- Temper<strong>at</strong>ure is NOT extrapol<strong>at</strong>ed<br />

(LXSFC) Default: F ! LXSFC = F !<br />

(ZVSFC) Default: 200. ! ZVSFC = 200 !<br />

!END!<br />

3-9