Table of Contents - The Atmospheric Studies Group at TRC

Table of Contents - The Atmospheric Studies Group at TRC Table of Contents - The Atmospheric Studies Group at TRC

29.01.2015 Views

Section 3: READ62 Upper Air Preprocessor Table 3-2 (continued) READ62 Control File Inputs Input group Variable Type Description (1) LHT Logical Height field control variable. If LHT = T, a sounding level is eliminated if the height field is missing. IF LHT = F, the sounding level is included in the output file but the height field is flagged with a "9999", if missing. LTEMP Logical Temperature field control variable. If LTEMP = T, a sounding level is eliminated if the temperature field is missing. If LTEMP = F, the sounding level is included in the output file but the temperature field is flagged with a "999.9", if missing. LWD Logical Wind direction field control variable. If LWD = T, a sounding level is eliminated if the wind direction field is missing. If LWD = F, the sounding level is included in the output file but the wind direction field is flagged with a "999", if missing. LWS Logical Wind speed field control variable. If LWS = T, a sounding level is eliminated if the wind speed is missing. If LWS = F, the sounding level is included in the output file but the wind speed field is flagged with a "999", if missing. LXTOP Logical Extrapolate missing data to from PVTOP to PSTOP (constant wind and temperature). T: Yes- F: No PVTOP Real Minimum pressure above which sounding is extrapolated (if missing) LXSFC Logical Extrapolate missing data down to surface (lowest wind speed extrapolate down with neutral power law. - Temperature is not extrapolated). T: Yes- F: No ZVSFC Real Maximum elevation (m) of the first valid data for extrapolation to the surface 3-6

Section 3: READ62 Upper Air Preprocessor Table 3-3: Sample READ62 Control File (READ62.INP) READ62.INP 2.1 Hour Start and End Times with Seconds ------------------------------------------------------------------------------- READ62 PROCESSOR CONTROL FILE ----------------------------- CALMET accepts upper air data (wind and temperature soundings) from UP.DAT files, where each UP.DAT file contains data for one station. READ62 processes soundings from standard NCDC data formats, reports problems with data entries, and produces an output file in the UP.DAT format. NCDC formats supported include TD-6201 and FSL. ------------------------------------------------------------------------------- INPUT GROUP: 0 -- Input and Output Files -------------- Input and Output files: ----------------------- Default Name Type File Name ------------ ---- --------- SOUNDING.DAT input ! INDAT = td6201.dat ! SUBSOUND.DAT input * SUBDAT = * UP.DAT output ! UPDAT = up2n.dat ! READ62.LST output ! RUNLST = read622n.lst ! All file names will be converted to lower case if LCFILES = T Otherwise, if LCFILES = F, file names will be converted to UPPER CASE (LCFILES) Default: T ! LCFILES = T ! T = lower case F = UPPER CASE NOTE: file/path names can be up to 70 characters in length !END! -------------------------------------------------------------------------------- INPUT GROUP: 1 -- Run control parameters -------------- --- Processing Period --- Starting date: Year (IBYR) -- No default ! IBYR = 1993 ! Month (IBMO) -- No default ! IBMO = 1 ! Day (IBDY) -- No default ! IBDY = 6 ! [00-23 UTC] Hour (IBHR) -- No default ! IBHR = 23 ! Second (IBSECN) -- No default ! IBSEC = 0 ! 3-7

Section 3: READ62 Upper Air Preprocessor<br />

<strong>Table</strong> 3-3:<br />

Sample READ62 Control File (READ62.INP)<br />

READ62.INP 2.1 Hour Start and End Times with Seconds<br />

-------------------------------------------------------------------------------<br />

READ62 PROCESSOR CONTROL FILE<br />

-----------------------------<br />

CALMET accepts upper air d<strong>at</strong>a (wind and temper<strong>at</strong>ure soundings) from<br />

UP.DAT files, where each UP.DAT file contains d<strong>at</strong>a for one st<strong>at</strong>ion.<br />

READ62 processes soundings from standard NCDC d<strong>at</strong>a form<strong>at</strong>s, reports<br />

problems with d<strong>at</strong>a entries, and produces an output file in the UP.DAT<br />

form<strong>at</strong>. NCDC form<strong>at</strong>s supported include TD-6201 and FSL.<br />

-------------------------------------------------------------------------------<br />

INPUT GROUP: 0 -- Input and Output Files<br />

--------------<br />

Input and Output files:<br />

-----------------------<br />

Default Name Type<br />

File Name<br />

------------ ---- ---------<br />

SOUNDING.DAT input ! INDAT = td6201.d<strong>at</strong> !<br />

SUBSOUND.DAT input * SUBDAT = *<br />

UP.DAT output ! UPDAT = up2n.d<strong>at</strong> !<br />

READ62.LST output ! RUNLST = read622n.lst !<br />

All file names will be converted to lower case if LCFILES = T<br />

Otherwise, if LCFILES = F, file names will be converted to UPPER CASE<br />

(LCFILES) Default: T ! LCFILES = T !<br />

T = lower case<br />

F = UPPER CASE<br />

NOTE: file/p<strong>at</strong>h names can be up to 70 characters in length<br />

!END!<br />

--------------------------------------------------------------------------------<br />

INPUT GROUP: 1 -- Run control parameters<br />

--------------<br />

--- Processing Period ---<br />

Starting d<strong>at</strong>e: Year (IBYR) -- No default ! IBYR = 1993 !<br />

Month (IBMO) -- No default ! IBMO = 1 !<br />

Day (IBDY) -- No default ! IBDY = 6 !<br />

[00-23 UTC] Hour (IBHR) -- No default ! IBHR = 23 !<br />

Second (IBSECN) -- No default ! IBSEC = 0 !<br />

3-7