Table G-2<br />

PRTMET Control File Inputs (PRTMET.INP)<br />

Input group Variable Type Description<br />

(0) METDAT character*132 Unformatted CALMET output file containing the<br />

meteorological <strong>and</strong> geophysical data to be printed<br />

RUNLST character*132 List file name.<br />

PRTTIME Character*132 Time-series file name<br />

LCFILES Logical Convert filename to upper (F) or lower (T) case<br />

(1) IBYR Integer Starting year of data to print (four digit)<br />

IBMO Integer Starting month<br />

IBDAY Integer Starting day<br />

IBHR Integer Starting hour (00-23)<br />

IEYR Integer Ending year of data to print (four digit)<br />

IEMO Integer Ending month<br />

IEDAY Integer Ending day<br />

IEHR Integer Ending hour (00-23)<br />

ICHR Integer Printing interval (hours) for printing/plotting field<br />

NBX Integer X grid cell of lower left corner of grid to print<br />

NBY Integer Y grid cell of lower left corner of grid to print<br />

NEX Integer X grid cell of upper right corner of grid to print<br />

NEY Integer Y grid cell of upper right corner of grid to print<br />

(2) LHDV Logical Control variable for printing of CALMET run<br />

variables stored in header records of output file.<br />

(F=do not print, T=print)<br />

LMETCF Logical Control variable for printing full CALMET<br />

control file image. (F=do not print, T=print)<br />

LSFC Logical Control variable for printing of X,Y surface<br />

station coordinates.<br />

(F=do not print, T=print)<br />

LUPC Logical Control variable for printing of X,Y upper air<br />

station coordinates.<br />

(F=do not print, T=print)<br />

LPRC Logical Control variable for printing of X,Y precipitation<br />

station coordinates.<br />

(F=do not print, T=print)<br />

LNEARS Logical Control variable for printing of nearest surface<br />

station number to each grid point.<br />

(F=do not print, T=print)<br />

MAR 2006 -- PostProc<br />

G-5