Operating data – 230 V Rated data DIM AKD-P00306 AKD-P00606 AKD-P01206 AKD-P02406 Rated supply voltage V~ 3× 108—264 V / 50—60 Hz 1× 108—264 V / 50—60 Hz 3× 240 V ±10 % Rated installed power for S1 operation kVA 1.2 2.38 3.82 7.6 Nominal current (±3 %) – at rated voltage 120 V Aef 3 6 12 – – at rated voltage 240 V Aef 3 6 12 24 Maximum current (max. 5s, ±3 %) Aef 9 18 30 48 Continuous power regen circuit (RBint) W – – 100 100 Continuous power regen circuit (RBext) max. Ws 60 (with 120 V) 20 (with 240 V) 60 (with 120 V) 20 (with 240 V) 160 (with 120 V) 55 (with 240 V) 180 (with 120 V) 60 (with 240 V) Continuous power regen circuit (RBext) max. kW 0.77 1.5 3 6 Peak power regen circuit (RBext) max. kW 5.4 5.4 5.4 11.8 Dimensions – Height mm 168 168 195 250 – Width mm 57 57 76 100 – Depth mm 153 153 186 230 – Depth with connectors mm 184 184 215 265 Operating data – 3 x 400 V Rated data DIM AKD-P00307 AKD-P00607 AKD-P01207 AKD-P02407 Rated supply voltage V~ 3× 216—528 V / 50—60 Hz Rated installed power for S1 operation kVA 2.24 4.49 7.65 15.2 Nominal current (±3 %) Aef 3 6 12 24 Maximum current (max. 5s, ±3 %) Aef 9 18 30 48 Continuous power regen circuit (RBint) W 80 100 100 200 Breaking energy of regen circuit capacitor Ws 5 (with 240 V) 35 (with 400 V) 20 (with 480 V) Continuous power regen circuit (RBext) max. 5 (with 240 V) 35 (with 400 V) 20 (with 480 V) 10 (with 240 V) 70 (with 400 V) 40 (with 480 V) 15 (with 240 V) 110 (with 400 V) 60 (with 480 V) at 240 V / 400 V a 480 V kW 0.77 / 1.5 1.5 / 3 3 / 6 6 / 12 Peak power regen circuit (RBext) max. kW 5.4 / 21.4 5.4 / 21.4 5.4 / 21.4 7.7 / 30.6 Dimensions – Height mm 256 256 256 310 – Width mm 70 70 70 105 – Depth mm 186 186 186 229 – Depth with connectors mm 221 221 221 264 Servoamplifier – 3× 400 V AKD P01207 Servoamplifier – 230 V AKD P00306
Notes: 12–13
- Page 1 and 2: Servodrives TGN servomotors AKD dig
- Page 3 and 4: Servomotors TGN synchronous servomo
- Page 5 and 6: Servomotors Dimensions of connector
- Page 7 and 8: Servomotors Dimensions of TGN2 with
- Page 9 and 10: Servomotors TGN4 servomotors 5.1-11
- Page 11 and 12: Servomotors TGN6 servomotors 18-44
- Page 13: Servoamplifiers Servozesilovače AK
Operating data – 230 V<br />
Rated data DIM <strong>AKD</strong>-P00306 <strong>AKD</strong>-P00606 <strong>AKD</strong>-P01206 <strong>AKD</strong>-P02406<br />
Rated supply voltage V~ 3× 108—264 V / 50—60 Hz<br />
1× 108—264 V / 50—60 Hz<br />
3× 240 V ±10 %<br />
Rated installed power for S1 operation kVA 1.2 2.38 3.82 7.6<br />
Nominal current (±3 %)<br />
– at rated voltage 120 V Aef 3 6 12 –<br />
– at rated voltage 240 V Aef 3 6 12 24<br />
Maximum current (max. 5s, ±3 %) Aef 9 18 30 48<br />
Continuous power regen circuit (RBint) W – – 100 100<br />
Continuous power regen circuit (RBext) max. Ws 60 (with 120 V)<br />
20 (with 240 V)<br />
60 (with 120 V)<br />
20 (with 240 V)<br />
160 (with 120 V)<br />
55 (with 240 V)<br />
180 (with 120 V)<br />
60 (with 240 V)<br />
Continuous power regen circuit (RBext) max. kW 0.77 1.5 3 6<br />
Peak power regen circuit (RBext) max. kW 5.4 5.4 5.4 11.8<br />
Dimensions<br />
– Height mm 168 168 195 250<br />
– Width mm 57 57 76 100<br />
– Depth mm 153 153 186 230<br />
– Depth with connectors mm 184 184 215 265<br />
Operating data – 3 x 400 V<br />
Rated data DIM <strong>AKD</strong>-P00307 <strong>AKD</strong>-P00607 <strong>AKD</strong>-P01207 <strong>AKD</strong>-P02407<br />
Rated supply voltage V~ 3× 216—528 V / 50—60 Hz<br />
Rated installed power for S1 operation kVA 2.24 4.49 7.65 15.2<br />
Nominal current (±3 %) Aef 3 6 12 24<br />
Maximum current (max. 5s, ±3 %) Aef 9 18 30 48<br />
Continuous power regen circuit (RBint) W 80 100 100 200<br />
Breaking energy of regen circuit capacitor Ws 5 (with 240 V)<br />
35 (with 400 V)<br />
20 (with 480 V)<br />
Continuous power regen circuit (RBext) max.<br />
5 (with 240 V)<br />
35 (with 400 V)<br />
20 (with 480 V)<br />
10 (with 240 V)<br />
70 (with 400 V)<br />
40 (with 480 V)<br />
15 (with 240 V)<br />
110 (with 400 V)<br />
60 (with 480 V)<br />
at 240 V / 400 V a 480 V kW 0.77 / 1.5 1.5 / 3 3 / 6 6 / 12<br />
Peak power regen circuit (RBext) max. kW 5.4 / 21.4 5.4 / 21.4 5.4 / 21.4 7.7 / 30.6<br />
Dimensions<br />
– Height mm 256 256 256 310<br />
– Width mm 70 70 70 105<br />
– Depth mm 186 186 186 229<br />
– Depth with connectors mm 221 221 221 264<br />
Servoamplifier – 3× 400 V<br />
<strong>AKD</strong> P01207<br />
Servoamplifier – 230 V<br />