DGMS <strong>Annual</strong> <strong>Report</strong>, <strong>2009</strong><br />

working space observed should have brightness preferably not less than one-twentieth<br />

<strong>of</strong> that <strong>of</strong> the brightest part. If strictly local lighting is used without adequate general<br />

illumination <strong>of</strong> the workplace, the figure for brightness contrast will greatly exceed<br />

the standard given above and cause server eye-strain and increases accident hazard.<br />

When the local lighting is used there must be employed in addition a moderate<br />

intensity <strong>of</strong> overhead lighting uniformly distributed.<br />

Standard <strong>of</strong> Distribution<br />

Lamps should be so installed in regard to height, spacing, reflectors or other<br />

accessories, as to secure a good distribution <strong>of</strong> light on the work area, avoiding<br />

objectionable shadows and sharp contrast <strong>of</strong> intensity. The illumination on the<br />

working plane should be as uniform as possible. The variation range <strong>of</strong> illumination,<br />

that is to say the ratio <strong>of</strong> the maximum illumination to the minimum illumination, is a<br />

measure <strong>of</strong> the distribution <strong>of</strong> light and should preferably be less than 3 to 1 and not<br />

greater than 4 to 1, as relating to the machinery or work benches as the case may be.<br />

As relating to machinery and adjoining passageways the range may, <strong>of</strong> course, be<br />

much wider but should preferably not exceed 20 to 1.<br />

Direct Illumination<br />

Illumination resulting from light emitted directly from the lamp, <strong>of</strong>f <strong>of</strong> the reflector or<br />

reflector diffuser, or through the refractor or diffuser lens, <strong>of</strong> a luminaries.<br />

Flood or Spotlight<br />

Any light fixture or lamp that incorporates a reflector or a refractor with a diffusing<br />

glass envelop to concentrate the light output into a directed beam in a particular<br />

direction.<br />

Lighting Fixture<br />

The assembly that houses the lamp or lamps and can include all or some <strong>of</strong> the<br />

following parts.<br />

‣ A housing, a mounting bracket or pole socket, a lamp holder, a ballast, a reflector<br />

or mirror, and/or a refractor or lens.<br />

Full Cut <strong>of</strong>f Light Fixture<br />

A luminaire light distribution where no light is emitted above the horizontal, and<br />

where the intensity at 80 degrees from nadir is no greater than 100 candela per 1000<br />

lamp lumens.<br />

Fully Shielded Light Fixture<br />

A lighting fixture constructed in such a manner, that all light emitted by the fixture,<br />

either directly from the lamp or a diffusing element, or indirectly by reflection or<br />

refraction from any part <strong>of</strong> the luminaire, is projected below the horizontal as<br />

161