1.6 Battery Wire Harness<br />
Check that the battery wire harness has the polarity correct.<br />
Set the meter to dc volts and measure the connector with<br />
the red lead on the red wire contact (top of the connector)<br />
and the black lead on the black wire contact (bottom of the<br />
connector) as shown in (figure A1.6.1). If both battery wire<br />
harnesses have full voltage and correct polarity, then proceed<br />
to step 1.8. If voltage is absent proceed to step 1.7. If<br />
polarity is reversed correct battery wiring.<br />
If polarity is reversed correct battery wiring.<br />
A1.6.1<br />
1000 OFF<br />
V DC 200<br />
20<br />
2000m<br />
200m<br />
20M<br />
2000K<br />
200K<br />
20K 2000 200<br />
OHM<br />
750<br />
200V AC<br />
V mA COM 10A<br />
200u<br />
2000u<br />
20m<br />
200m<br />
10A<br />
A DC<br />
DIGITAL MULTIMETER<br />
1.7 Battery Fuse<br />
Check that the battery fuse is in good condition. With the<br />
batteries disconnected remove the fuse cap, inspect the<br />
fuse to see if the fuse is blown. To make sure the fuse is<br />
not blown, set the meter to ohms and measure the resistance<br />
across the fuse. see (figure A1.7.1). If the meter<br />
reads more than one ohm, change the fuse, or else proceed<br />
to the next step.<br />
If the meter reads more than one ohm, change the Battery fuse.<br />
A1.7.1<br />
1000 OFF<br />
V DC 200<br />
20<br />
2000m<br />
200m<br />
20M<br />
2000K<br />
200K<br />
20K 2000 200<br />
OHM<br />
750<br />
200V AC<br />
200u<br />
2000u<br />
20m<br />
200m<br />
10A<br />
V mA COM 10A<br />
A DC<br />
DIGITAL MULTIMETER<br />
1.8 Circuit Breaker Test<br />
To check the circuit breaker set the meter to ohms and<br />
measure the resistance across the circuit breaker as shown<br />
in (figure A1.8.1). If the meter reads more than 1 ohm,<br />
then change the circuit breaker, otherwise proceed to next<br />
step.<br />
A1.8.1<br />
1000 OFF<br />
V DC 200<br />
20<br />
2000m<br />
200m<br />
20M<br />
2000K<br />
200K<br />
20K 2000 200<br />
OHM<br />
750<br />
200V AC<br />
V mA COM 10A<br />
200u<br />
2000u<br />
20m<br />
200m<br />
10A<br />
A DC<br />
DIGITAL MULTIMETER<br />
If the meter reads more than 1 ohm, then change the circuit breaker.<br />
1.9 Main Harness<br />
If the above steps did not correct the problem, change the<br />
main harness.<br />
If the previous steps did not correct the problem, change the main harness.<br />