Disassembly/Reassembly, and Adjustment (cont)<br />
Step 9 - Wire Harness<br />
Disassembly<br />
a. Remove all the zip ties on the base frame.<br />
b. Unwrap all the wire loom ties securing the harness to the<br />
frame.<br />
c. For the main harness, remove the two screws that holding<br />
the female beau plug (figure A4.22).<br />
d. Remove the circuit breaker locking nut and push it<br />
through the bracket (figure A4.23), then remove the main<br />
wire harness.<br />
e. For the light and A/C harness, remove the rear shroud<br />
(figure A4.24)<br />
and then remove the mounting screws on the A/C plug<br />
bracket.(figure A4.23).<br />
f. Push the light harness through the bracket.<br />
g. Pull the A/C harness through the bracket.<br />
Reassembly<br />
a. Reverse above instructions.<br />
Adjustment<br />
Note: The circuit breaker can be removed without removing<br />
the main harness.<br />
a. Pull the quick disconnect terminal out from the bottom of<br />
the circuit breaker, then remove the circuit breaker locking<br />
nut.<br />