13. Function Code List<br />

Type [34]: Communication error codes<br />

15 8 7 0<br />

Description of alarms in the communication through the link (RS-485, T-Link, field bus). The<br />

following data is set to the monitor data M26 according to the communication status. The codes<br />

listed in the column "KEYPAD panel display" is displayed on the KEYPAD panel as a<br />

communication error .<br />

Code<br />

KEYPAD panel<br />

display<br />

Communication error name Description<br />

0 - No communication error 1 Normal communication<br />

2 A data is written to an unused address of the function code (writing<br />

to address out of the specified range is defined separately).<br />

3 Data is read from missing function code address in the middle of<br />

continuous read. The data will be "0000".<br />

4 Writing to the S area while link operation is disabled. The data will<br />

not be reflected and cause no error.<br />

5 A data out of range is written to the S area. The data is written after<br />

adjusted to the upper or the lower limit.<br />

6 Access from another link or the KEYPAD panel occurs during data<br />

writing (EEPROM other than the S area is accessed).<br />

7 Writing to operation data (such as tuning or initialization) during<br />

multiple function codes are being written once through the link. The<br />

inverter decides that the procedure is canceled and continues the<br />

writing.<br />

8 Writing to/reading from option function codes that are not displayed<br />

on the KEYPAD panel.<br />

9 Writing/reading a special function code for the lifting machine in the<br />

standard mode<br />

10 Writing/reading a function code for the standard mode in the lifting<br />

machine mode<br />

1 to 32 - Alarm codes specific to the<br />

VG7S<br />

Alarm codes specific to models other than communication errors.<br />

33 to 70 - Not used<br />

71 04 Checksum error, CRC error Software error Checksum value or CRC value does not<br />

match.<br />

72 05 Parity error Hardware error Parity does not match.<br />

73 06 Others (such as overrun,<br />

framing)<br />

Physical (reception) errors other than above.<br />

74 01 Format error Incorrect format.<br />

75 01 Command error<br />

Characters requesting transmission are incorrect. Characters<br />

terminating transmission are not in the specified order.<br />

Codes other than the specified commands are transmitted.<br />

76 07 Link priority error 1 Writing to the S area through RS485 while a link option is installed.<br />

2 Writing to the S area through a link with lower priority while multiple<br />

link options are installed.<br />

77 07 No right to write function<br />

code data<br />

Not used for VG7S<br />

78 02 Function code error 1 Access to a data out of the address range of the function codes<br />

(such as access to a data over F80).<br />

2 Writing data over 16 words.<br />

79 07 Error on writing to writedisabled<br />

data<br />

1 Write-disabled function codes (Read-only data or the M area).<br />

2 Function codes write-disabled during operation.<br />

3 Writing through the link to data out of the S area in "write-disabled<br />

through link" mode. Note that F00 or "Write enable for KEYPAD"<br />

cannot protect from writing through the link.<br />

4 Function codes that cannot be written through the link (link function<br />

codes: H31 to 40).<br />

5 Writing to M1 function code (P) area when motor parameters are<br />

protected.<br />

6 Writing through the link in the copy mode operation of the KEYPAD<br />

panel.<br />

80 03 Data error Written data is out of the setting range in the area other than the S<br />

area.<br />

81 07 Error during writing Another writing request comes from the same source while writing<br />

function code data (EEPROM other than the S area is accessed).<br />

Note: The alarm codes 1 to 32 constitute a code system specific to the VG7S different from the<br />

assignment for the general-purpose inverters.<br />

The communication error codes 71 to 81 are common to the different models. Note that some<br />

causes of alarm are specific to models.<br />

The KEYPAD panel does not display raw communication error codes but the values in the<br />

"KEYPAD panel display" column in the table above.<br />

The KEYPAD panel displays "∗∗" when it receives data that does not have a corresponding<br />

"KEYPAD panel display" in the table above.<br />

13-33