13. Function Code List<br />
Type [34]: Communication error codes<br />
15 8 7 0<br />
Description of alarms in the communication through the link (RS-485, T-Link, field bus). The<br />
following data is set to the monitor data M26 according to the communication status. The codes<br />
listed in the column "KEYPAD panel display" is displayed on the KEYPAD panel as a<br />
communication error .<br />
Code<br />
KEYPAD panel<br />
display<br />
Communication error name Description<br />
0 - No communication error 1 Normal communication<br />
2 A data is written to an unused address of the function code (writing<br />
to address out of the specified range is defined separately).<br />
3 Data is read from missing function code address in the middle of<br />
continuous read. The data will be "0000".<br />
4 Writing to the S area while link operation is disabled. The data will<br />
not be reflected and cause no error.<br />
5 A data out of range is written to the S area. The data is written after<br />
adjusted to the upper or the lower limit.<br />
6 Access from another link or the KEYPAD panel occurs during data<br />
writing (EEPROM other than the S area is accessed).<br />
7 Writing to operation data (such as tuning or initialization) during<br />
multiple function codes are being written once through the link. The<br />
inverter decides that the procedure is canceled and continues the<br />
writing.<br />
8 Writing to/reading from option function codes that are not displayed<br />
on the KEYPAD panel.<br />
9 Writing/reading a special function code for the lifting machine in the<br />
standard mode<br />
10 Writing/reading a function code for the standard mode in the lifting<br />
machine mode<br />
1 to 32 - Alarm codes specific to the<br />
VG7S<br />
Alarm codes specific to models other than communication errors.<br />
33 to 70 - Not used<br />
71 04 Checksum error, CRC error Software error Checksum value or CRC value does not<br />
match.<br />
72 05 Parity error Hardware error Parity does not match.<br />
73 06 Others (such as overrun,<br />
framing)<br />
Physical (reception) errors other than above.<br />
74 01 Format error Incorrect format.<br />
75 01 Command error<br />
Characters requesting transmission are incorrect. Characters<br />
terminating transmission are not in the specified order.<br />
Codes other than the specified commands are transmitted.<br />
76 07 Link priority error 1 Writing to the S area through RS485 while a link option is installed.<br />
2 Writing to the S area through a link with lower priority while multiple<br />
link options are installed.<br />
77 07 No right to write function<br />
code data<br />
Not used for VG7S<br />
78 02 Function code error 1 Access to a data out of the address range of the function codes<br />
(such as access to a data over F80).<br />
2 Writing data over 16 words.<br />
79 07 Error on writing to writedisabled<br />
data<br />
1 Write-disabled function codes (Read-only data or the M area).<br />
2 Function codes write-disabled during operation.<br />
3 Writing through the link to data out of the S area in "write-disabled<br />
through link" mode. Note that F00 or "Write enable for KEYPAD"<br />
cannot protect from writing through the link.<br />
4 Function codes that cannot be written through the link (link function<br />
codes: H31 to 40).<br />
5 Writing to M1 function code (P) area when motor parameters are<br />
protected.<br />
6 Writing through the link in the copy mode operation of the KEYPAD<br />
panel.<br />
80 03 Data error Written data is out of the setting range in the area other than the S<br />
area.<br />
81 07 Error during writing Another writing request comes from the same source while writing<br />
function code data (EEPROM other than the S area is accessed).<br />
Note: The alarm codes 1 to 32 constitute a code system specific to the VG7S different from the<br />
assignment for the general-purpose inverters.<br />
The communication error codes 71 to 81 are common to the different models. Note that some<br />
causes of alarm are specific to models.<br />
The KEYPAD panel does not display raw communication error codes but the values in the<br />
"KEYPAD panel display" column in the table above.<br />
The KEYPAD panel displays "∗∗" when it receives data that does not have a corresponding<br />
"KEYPAD panel display" in the table above.<br />