Type [29]: Inverter model (common to entire FUJI inverter system)<br />

The number is fixed to 1213h or 1214h or 1216h for the VG inverters.<br />

200V system: fixed to 1213h<br />

400V system: fixed to 1214h<br />

690V system: fixed to 1216h<br />

Type [31]: Speed<br />

15 8 7 0<br />

Data (0 to ±20,000) → (0 to ±12,000 × r/min) : (Data) × Nmax/20,000 conversion<br />

(Example) When the maximum speed is Nmax=1,500r/min,<br />

• If you want to direct a speed command of 1,000r/min,<br />

1,000<br />

Specify a data of × 20,000 → 13,333.<br />

1,500<br />

• If the read out data is 3,500,<br />

1,500<br />

You can determine the speed is × 3,500 → 262.5r/min.<br />

20,000<br />

Type [32]: Operation commands, [33]: Y1 to Y18<br />

This type is the same as S06 and S07.<br />

15 8 7 0<br />

[32] [33]<br />

0) FWD (forward operation command) Y1<br />

1) REV (reverse operation command) Y2<br />

2) X1 Y3<br />

3) X2 Y4<br />

4) X3 Y5A<br />

5) X4 Not used<br />

6) X5 Not used<br />

7) X6 Not used<br />

8) X7 Y11<br />

9) X8 Y12<br />

10) X9 Y13<br />

11) X11 Y14<br />

12) X12 Y15<br />

13) X13 Y16<br />

14) X14 Y17<br />

15) RST (RESET command) Y18<br />

13-32<br />

0: OFF<br />

1: ON