14.11.2012 Views

Appendix

Appendix

Appendix

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

13.3 Function Code List Dedicated to Communication<br />

You can refer to or change the following functions only through the integrated RS-485 or the field bus<br />

options (T-link, SX, field bus). The S area is write-only and the M area is read-only. The S and the M areas<br />

are common to FUJI inverters. Any FUJI inverters that can link to communication system can use these<br />

areas.<br />

See 13.4 "Data Format List" to monitor to or change a function code after you check the "Type" column of<br />

the function code in the list.<br />

13.3.1 S Function Code<br />

This is a write-only area. You should use the function code H30 "Serial link" to initialize. See the function<br />

description of H30 for more details.<br />

485<br />

number Link number<br />

S01 701h 1( 1 h) Frequency/speed -24000 to 24000 r/min<br />

command (Setting 1) : (data) *Nmax/20000<br />

S02 702h 2( 2 h) Torque command -327.68 to 327.67 %<br />

Fcode<br />

Communication<br />

address<br />

Function code name Setting range<br />

*1 Do not write settings out of the data range. As well, be careful when handling positive or negative data<br />

as shown in the following example.<br />

Example: To write “40000(d) in S02 (“40000” is not positive.)<br />

4000 – 65536 = -25536<br />

Therefore “-255.36%” is written actually.<br />

This is related to the process using the hexadecimal.<br />

No communication error is caused.<br />

13-26<br />

Min<br />

increment<br />

Unit Type<br />

1 r/min 31<br />

0.01 % 7<br />

S03 703h 3( 3 h) Torque current<br />

0.01% / 1d *1<br />

-327.68 to 327.67 % 0.01 % 7<br />

command<br />

0.01% / 1d *1<br />

S04 704h 4( 4 h) Magnetic-flux command -327.68 to 327.67 %<br />

0.01% / 1d *1<br />

0.01 % 7<br />

S05 705h 5( 5 h) Orientation position<br />

command<br />

0000 to FFFF 1 - 9<br />

S06 706h 6( 6 h) Operation command 1 0000 to FFFF 1 - 32<br />

S07 707h 7( 7 h) Universal Do 0000 to FFFF 1 - 33<br />

S08 708h 8( 8 h) Acceleration time 0.0 to 3600.0 s 0.1 s 2<br />

S09 709h 9( 9 h) Deceleration time 0.0 to 3600.0 s 0.1 s 2<br />

S10 70Ah 10( A h) Torque limiter level 1 -327.68 to 327.67 %<br />

0.01% / 1d *1<br />

0.01 % 7<br />

S11 70Bh 11( B h) Torque limiter level 2 -327.68 to 327.67 %<br />

0.01% / 1d *1<br />

0.01 % 7<br />

S12 70Ch 12( C h) Operation command 2 0000 to FFFF 1 - 9