Appendix
Appendix Appendix
13. Function Code List Communication address Fcode 485 Link number number Function name Function directory name You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. A: Alternative Motor Parameters You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. Setting range 13-19 Control type: Available/ Not available PG LES VF SM h71 447h Reserved 2 0 to 6 It is not necessary to set usually. If these tuning are finished, this data code returns to 0. 62 x x x o o o o o 0 : Inactive o o o o 1 : ACR system tuning x x x x 2 : Voltage gain tuning (execution without connecting motor) o o o o 3 : Voltage sensor offset tuning o o o o 4 : Current sensor balance tuning o o o o 5 : Magnet pole position tuning (for SM driving) x x x x 6 : Shunt registor gain tuning o o o o h72 448h Reserved 3 0 to 9999 0 : standard 1 to 9999 : Undecided 0 x o x o o o o o h73 449h Reserved 4 0 to 9999 0 : standard 1 to 9999 : Undecided 0 x o x o o o o o Communication address Fcode 485 Link number number a01 501h Setting M2 parameter Function name Function directory name M2-Control method 0 to 1 M2 is an induction motor only for the vector control. 0 : Vector control with PG 1 : Vector control without PG a02 502h M2-Rated capacity 0.00 to 500.00kW at F60=0 0.00 to 600.00HP at F60=1 a03 503h M2-Rated current 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A Type Copy Save all Initialization Lifting machine Underline indicates a factory setting. PG LES VF SM 55 o o x o o x x o 3 o o x o o x x o 13 o o x o o x x o a04 504h M2-Rated voltage 80 to 999 V 0 o o x o o x x o a05 505h M2-Rated speed 50 to 1500 to 24000 r/min 0 o o x o o x x o a06 506h M2-Maximum speed 50 to 1500 to 24000 r/min 0 o o x o o x x o a07 507h M2-Poles 2 to 4 to 12 (poles) 1 o o x o o x x o a08 508h M2-%R1 0.00 to 30.00 % 3 o o x o o x x o a09 509h M2-%X 0.00 to 50.00 % 3 o o x o o x x o a10 50Ah M2-Exciting current 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A a11 50Bh M2-Torque current 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A 13 o o x o o x x o 13 o o x o o x x o a12 50Ch M2-Slip (Driving) 0.001 to 10.000 Hz 4 o o x o o x x o a13 50Dh M2-Slip (Braking) 0.001 to 10.000 Hz 4 o o x o o x x o a14 50Eh M2-Iron loss coefficient 1 0.00 to 10.00 % 3 o o x o o x x o a15 50Fh M2-Iron loss coefficient 2 0.00 to 10.00 % 3 o o x o o x x o a16 510h M2-Iron loss coefficient 3 0.00 to 10.00 % 3 o o x o o x x o a17 511h M2-Magnetic saturation coefficient 1 a18 512h M2-Magnetic saturation coefficient 2 Setting range 0.0 to 100.0 % 2 o o x o o x x o 0.0 to 100.0 % 2 o o x o o x x o a19 513h M2-Magnetic saturation coef. 3 0.0 to 100.0 % 2 o o x o o x x o a20 514h M2-Magnetic saturation coef.4 0.0 to 100.0 % 2 o o x o o x x o a21 515h M2-Magnetic saturation coef. 5 0.0 to 100.0 % 2 o o x o o x x o a22 516h M2-Secondary time constant 0.001 to 9.999 s 4 o o x o o x x o a23 517h M2-Induced voltage coefficient 0 to 999 V 0 o o x o o x x o a24 518h M2-R2 correction coef. 1 0.000 to 5.000 4 o o x o o x x o Type Copy Save all Initialization Control type: Available/ Not available Lifting machine Underline indicates a factory setting.
Communication address Fcode 485 Link number number You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. 13-20 PG LES VF SM a25 519h M2-R2 correction coef. 2 0.000 to 5.000 4 o o x o o x x o a26 51Ah M2-R2 correction coef. 3 0.010 to 5.000 4 o o x o o x x o a27 51Bh M2-Exciting correction coef. 0.000 to 5.000 4 o o x o o x x o a28 51Ch M2-ACR-P gain 0.1 to 1.0 to 20.0 2 o o x o o x x o a29 51Dh M2-ACR I-gain 0.5 to 1.0 to 100.0 ms 2 o o x o o x x o a30 51Eh M2-PG pulses 100 to 1024 to 60000 0 o o x o x x x o a31 51Fh M2-thermistor selection a32 520h M2-Electronic thermal overload relay (selection) a33 521h M2-Electronic thermal overload relay (Level) a34 522h M2-Electronic thermal overload relay (Thermal 0 to 1 to 3 0 : No use thermistor 1 : NTC thermistor 2 : PTC thermistor 3 : Ai (M-TMP) Please do the protection level setting of the motor at E30-E37. M2-Electronic thermal 0 to 2 overload relay (Selection) The motor overheating protection operates by using NTC thermistor with the motor only for VG. In this case, please make setting a Electronic thermal "Inactive". 0 : Inactive 1 : Active (for standard motor, self-cooling fan) 2 : Active (for inverter motor, separate cooling fan) a35 523h E5 h M3-Rated capacity time constant) M3-Rated capacity 0.00 to 500.00kW at F60=0 0.00 to 600.00HP at F60=1 a36 524h E6 h M3-Rated current 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A 84 o o x o o x x o 85 o o x o o x x o 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A 13 o o x o o x x o 0.5 to 75.0 min 2 o o x o o x x o 3 o o x x x o x x 13 o o x x x o x x a37 525h E7 h M3-Rated voltage 80 to 999 V 0 o o x x x o x x a38 526h E8 h M3-Maximum voltage 80 to 999 V 0 o o x x x o x x a39 527h E9 h M3-Rated speed 50 to 1500 to 24000 r/min 0 o o x x x o x x a40 528h EA h M3-Maximum speed 50 to 1500 to 24000 r/min 0 o o x x x o x x a41 529h EB h M3-Poles 2 to 4 to 12 (poles) 1 o o x x x o x x a42 52Ah EC h M3-%R1 0.00 to 30.00 % 3 o o x x x o x x a43 52Bh ED h M3-%X 0.00 to 30.00 % 3 o o x x x o x x a44 52Ch EE h M3-Exciting current 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A 13 o o x x x o x x a45 52Dh EF h M3-Slip compensation control -20.000 to 0.000 to 5.000 Hz 8 o o x x x o x x a46 52Eh F0 h M3-Torque boost 0.0 to 20.0 0.0 : Automatic torque boost (for CT load) 0.1 to 0.9 : Manual torque boost (for Square torque load) 1.0 to 1.9 : Manual torque boost (for VT load) 2.0 to 20.0 : Manual torque boost (for CT load) 2 o o x x x o x x a47 52Fh F1 h M3-Thermistor selection a48 530h F2 h M3-Electronic thermal overload relay (selection) Function name Function directory name a49 531h F3 h M3-Electronic thermal overload relay (Level) a50 532h F4 h M3-Electronic thermal overload relay (Thermal time constant) 0 to 1 to 3 0 : No use thermistor 1 : NTC thermistor 2 : PTC thermistor 3 : Ai (M-TMP) Please do the protection level setting of the motor at E30-E32. M3-Electronic thermal 0 to 2 overload relay (Selection) 0 : Inactive (when using PTC thermistor) 1 : Active (for standard motor, self-cooling fan) 2 : Active (for inverter motor, separate-cooling fan) 0.01 to 99.99A 100.0 to 999.9A 1000 to 2000A Setting range 84 o o x x x o x x 85 o o x x x o x x 13 o o x x x o x x 0.5 to 75.0 min 2 o o x x x o x x Type Copy Save all Initialization Control type: Available/ Not available Lifting machine Underline indicates a factory setting.
- Page 2 and 3: 12. Operation Data 12.1 Frequency R
- Page 4 and 5: 12. Operation Data 12.5 Impact load
- Page 6 and 7: 12. Operation Data 12.8 Speed-torqu
- Page 8: 12. Operation Data 12.11 Comparison
- Page 11 and 12: 13.2 Function Code List 13.2.1 Func
- Page 13 and 14: Communication Control type: Availab
- Page 15 and 16: Communication Control type: Availab
- Page 17 and 18: Communication Control type: Availab
- Page 19 and 20: Communication Control type: Availab
- Page 21 and 22: Communication address Fcode Functio
- Page 23 and 24: Fcode Communication address 485 num
- Page 25 and 26: H: High Performance Functions Commu
- Page 27: Communication address Fcode 485 Lin
- Page 31 and 32: Communication address Fcode 485 Lin
- Page 33 and 34: Communication address Fcode Functio
- Page 35 and 36: 13.3 Function Code List Dedicated t
- Page 37 and 38: 485 Min increment Unit Type number
- Page 39 and 40: Type [14]: Cause of alarm 15 12 8 7
- Page 41 and 42: Type [29]: Inverter model (common t
- Page 43 and 44: Type [35]: X function normally open
- Page 46 and 47: 14. Replacement Data When replacing
- Page 48 and 49: 14. Replacement Data 14.2.2 Replaci
- Page 50 and 51: 14. Replacement Data 14.3 Terminal
- Page 52 and 53: 14. Replacement Data 14.3.2 Replaci
- Page 54 and 55: 14. Replacement Data 14.3.3 Replaci
- Page 56 and 57: 14. Replacement Data 14.4 Terminal
- Page 58 and 59: 14. Replacement Data Cat- ego- ry T
- Page 60 and 61: 14. Replacement Data Cat- ego- ry A
- Page 62 and 63: 14. Replacement Data 14.4.3 Replaci
- Page 64 and 65: 14. Replacement Data � Difference
- Page 66 and 67: 14. Replacement Data FRENIC5000 VG5
- Page 68 and 69: 14. Replacement Data 14.6.2 Replaci
- Page 70 and 71: 14. Replacement Data FRENIC5000 VG3
- Page 72 and 73: 14. Replacement Data � 400V serie
- Page 74 and 75: 14. Replacement Data � 400V serie
- Page 76 and 77: 14. Replacement Data � 400V serie
13. Function Code List<br />
Communication<br />
address<br />
Fcode<br />
485 Link<br />
number number<br />
Function name Function directory name<br />
You can change the setting of a function indicated by during operation.<br />
You should stop operation to change the setting of other functions.<br />
A: Alternative Motor Parameters<br />
You can change the setting of a function indicated by during operation.<br />
You should stop operation to change the setting of other functions.<br />
Setting range<br />
13-19<br />
Control type: Available/<br />
Not available<br />
PG LES VF SM<br />
h71 447h Reserved 2 0 to 6<br />
It is not necessary to set usually.<br />
If these tuning are finished, this data code returns<br />
to 0.<br />
62 x x x o o o o o<br />
0 : Inactive o o o o<br />
1 : ACR system tuning x x x x<br />
2 : Voltage gain tuning (execution without<br />
connecting motor)<br />
o o o o<br />
3 : Voltage sensor offset tuning o o o o<br />
4 : Current sensor balance tuning o o o o<br />
5 : Magnet pole position tuning (for SM driving) x x x x<br />
6 : Shunt registor gain tuning o o o o<br />
h72 448h Reserved 3 0 to 9999<br />
0 : standard<br />
1 to 9999 : Undecided<br />
0 x o x o o o o o<br />
h73 449h Reserved 4 0 to 9999<br />
0 : standard<br />
1 to 9999 : Undecided<br />
0 x o x o o o o o<br />
Communication<br />
address<br />
Fcode<br />
485 Link<br />
number number<br />
a01 501h Setting M2<br />
parameter<br />
Function name Function directory name<br />
M2-Control method 0 to 1<br />
M2 is an induction motor only for the vector control.<br />
0 : Vector control with PG<br />
1 : Vector control without PG<br />
a02 502h M2-Rated capacity 0.00 to 500.00kW at F60=0<br />
0.00 to 600.00HP at F60=1<br />
a03 503h M2-Rated current 0.01 to 99.99A<br />
100.0 to 999.9A<br />
1000 to 2000A<br />
Type<br />
Copy<br />
Save all<br />
Initialization<br />
Lifting<br />
machine<br />
Underline indicates a factory setting.<br />
PG LES VF SM<br />
55 o o x o o x x o<br />
3 o o x o o x x o<br />
13 o o x o o x x o<br />
a04 504h M2-Rated voltage 80 to 999 V 0 o o x o o x x o<br />
a05 505h M2-Rated speed 50 to 1500 to 24000 r/min 0 o o x o o x x o<br />
a06 506h M2-Maximum speed 50 to 1500 to 24000 r/min 0 o o x o o x x o<br />
a07 507h M2-Poles 2 to 4 to 12 (poles) 1 o o x o o x x o<br />
a08 508h M2-%R1 0.00 to 30.00 % 3 o o x o o x x o<br />
a09 509h M2-%X 0.00 to 50.00 % 3 o o x o o x x o<br />
a10 50Ah M2-Exciting current 0.01 to 99.99A<br />
100.0 to 999.9A<br />
1000 to 2000A<br />
a11 50Bh M2-Torque current 0.01 to 99.99A<br />
100.0 to 999.9A<br />
1000 to 2000A<br />
13 o o x o o x x o<br />
13 o o x o o x x o<br />
a12 50Ch M2-Slip (Driving) 0.001 to 10.000 Hz 4 o o x o o x x o<br />
a13 50Dh M2-Slip (Braking) 0.001 to 10.000 Hz 4 o o x o o x x o<br />
a14 50Eh M2-Iron loss coefficient 1 0.00 to 10.00 % 3 o o x o o x x o<br />
a15 50Fh M2-Iron loss coefficient 2 0.00 to 10.00 % 3 o o x o o x x o<br />
a16 510h M2-Iron loss coefficient 3 0.00 to 10.00 % 3 o o x o o x x o<br />
a17 511h M2-Magnetic saturation<br />
coefficient 1<br />
a18 512h M2-Magnetic saturation<br />
coefficient 2<br />
Setting range<br />
0.0 to 100.0 % 2 o o x o o x x o<br />
0.0 to 100.0 % 2 o o x o o x x o<br />
a19 513h M2-Magnetic saturation<br />
coef. 3<br />
0.0 to 100.0 % 2 o o x o o x x o<br />
a20 514h M2-Magnetic saturation<br />
coef.4<br />
0.0 to 100.0 % 2 o o x o o x x o<br />
a21 515h M2-Magnetic saturation<br />
coef. 5<br />
0.0 to 100.0 % 2 o o x o o x x o<br />
a22 516h M2-Secondary time<br />
constant<br />
0.001 to 9.999 s 4 o o x o o x x o<br />
a23 517h M2-Induced voltage<br />
coefficient<br />
0 to 999 V 0 o o x o o x x o<br />
a24 518h M2-R2 correction coef. 1 0.000 to 5.000 4 o o x o o x x o<br />
Type<br />
Copy<br />
Save all<br />
Initialization<br />
Control type: Available/<br />
Not available<br />
Lifting<br />
machine<br />
Underline indicates a factory setting.