13. Function Code List Communication Control type: Available/ address Not available Fcode 485 Link number number Function name Function directory name Setting range PG LES VF SM 27 : Synchronization completion signal (SY-C) o x x x 28 : Lifetime alarm (LIFE) o o o o 29 : Under acceleration (U-ACC) o o o o 30 : Under deceleration (U-DEC) o o o o 31 : Inverter overload early warning (INV-OL) o o o o 32 : Motor overheat early warning (M-OH) o o o o 33 : Motor overload early warning (M-OL) o o o o 34 : DB overload early warning (DB-OL) o o x o 35 : Link transmission error (LK-ERR) o o o o 36 : load adaptive control under limiting (ANL) o x x x 37 : load adaptive control under calculation (ANC) o x x x 38 : Analog torque bias hold (TBH) o o x o 39 to 47 : Option DO1 to 9 (O-DO1 to O-DO9) o o o o e16 110h 86 h Y2 terminal function 0 to 2 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e17 111h 87 h Y3 terminal function 0 to 3 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e18 112h 88 h Y4 terminal function 0 to 4 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e19 113h 89 h Y5 terminal function 0 to 14 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e20 114h 8A h Y11 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e21 115h 8B h Y12 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e22 116h 8C h Y13 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e23 117h 8D h Y14 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e24 118h 8E h Y15 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e25 119h 8F h Y16 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e26 11Ah 90 h Y17 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e27 11Bh 91 h Y18 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o e28 11Ch Y terminal function 0000 to 001F 36 o o o o o o o o normally open/close Setting of normal state of Y1to Y4,RY. 0 : Normally open 1 : Normally close e29 11Dh 92 h PG pulse output selection e30 11Eh Motor OH protection Motor OH protection (temperature) e31 11Fh M-OH early warning (temperature) e32 120h CD h M1-M3 (operation level PTC) You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. 0 to 9 0 : No dividing 1 : 1/2 2 : 1/4 3 : 1/8 4 : 1/16 5 : 1/32 6 : 1/64 0 to 6 : Internal PG inputs are output after being divided. 7 : Pulse oscillation mode (A/B 90° phase difference signal) Internal speed reference is output after pulse conversion. 8 : PG (PD) Pulse inputs for position encoder are directly output. 9 : PG (PR) Pulse inputs for position command are directly output. 100 to 150 to 200 ℃ It is effective when NTC thermistor is used with selected motor (M1,M2). 50 to 75 to 200 ℃ It is effective when NTC thermistor is used with selected motor (M1,M2). 13-9 92 o o o o x x o o 0 o o o o o o o o 0 o o o o o o o o 0.00 to 1.60 to 5.00 V 3 o o o o o o o o e33 121h INV-OL early warning 25 to 90 to 100 % 0 o o o o o o o o e34 122h M-OL early warning 25 to 90 to 100 % 0 o o o o o o o o e35 123h DB overload protection 0 to 10 to 100 % 0 o o o o o x o o e36 124h DB-OL early warning 0 to 80 to 100 % 0 o o o o o x o o e37 125h DB thermal time constant 0 to 100 to 1000 s 0 o o o o o x o o Type Copy Save all Initialization Lifting machine Underline indicates a factory setting.

Communication Control type: Available/ address Not available Fcode 485 Link number number Function name Function directory name Setting range PG LES VF SM e38 126h 93 h Speed detection Speed detection method 000 to 111 9 o o o o o x o o method (N-DT1) (N-DT2) (N-DT3) 0 : Detected speed 1 : Speed reference Only reference values are effective under VF control. e39 127h 94 h N-DT1 Level 0 to 1500 to 24000 r/min 0 o o o o o o o o e40 128h 95 h N-DT2 Level -24000 to 1500 to 24000 r/min 5 o o o o o o o o e41 129h 96 h N-DT3 Level -24000 to 1500 to 24000 r/min 5 o o o o o o o o e42 12Ah 97 h N-AR detection width 1.0 to 3.0 to 20.0 % 2 o o o o o x o o e43 12Bh 98 h N-AG detection width 1.0 to 3.0 to 20.0 % 2 o o o o o x o o e44 12Ch 99 h N-AG off-delay timer 0.000 to 0.100 to 1.000 s 4 o o o o o x o o e45 12Dh 9A h Speed disagreement alarm You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. 0 to 21 Place of 1: Speed disagreement alarm (Er9) 0: Not used 1: Used Place of 10: Lin phase loss detection 0: Level without DCR 1: Level with DCR 2: For manufacturer (Do not specify.) 13-10 9 o o o o o x o o e46 12Eh 9B h Torque detection level 1 0 to 30 to 300 % When the V/F control is used, the calculation value is set. 16 o o o o o o o o e47 12Fh 9C h Torque detection level 2 0 to 30 to 300 % When the V/F control is used, the calculation value is set. 16 o o o o o o o o e48 130h 9D h Magnetic flux detection level 10 to 100 % 16 o o o o o x x o e49 131h Ai function selection Ai1 function selection 0 to 18 59 o o o o o o o o 0 : Input sigunal off (OFF) o o o o 1 : Auxiliary speed setting 1 (before ramp function) (AUX-N1) ±10V/±Nmax o o o o 2 : Auxiliary speed setting 2 (after ramp function) (AUX-N2) ±10V/±Nmax o o o o 3 : Torque limiter level 1 (TL-REF1) ±10V/±150% o o x o 4 : Torque limiter level 2 (TL-REF2) ±10V/±150% o o x o 5 : Torque bias level (TB-REF) ±10V/±150% o o x o 6 : Torque reference (before limit function) (T-REF) ±10V/±150% o o x o 7 : Torque current reference (IT-REF) ±10V/±150% 8 : Creep speed 1 for UP/DOWN control (CRP-N1) ±10V/±Nmax 9 : Creep speed 2 for UP/DOWN control (CRP-N2) ±10V/±Nmax 10 : Magnetic flux reference (MF-REF) ±10V/±100% o o x o o o o o o o o o o o x x 11 : Detected line speed (LINE-N) ±10V/±Nmax o o o o 12 : Motor temperature feedback (M-TMP) +10V/ 200°C o o o o 13 : Speed override (N-OR) ±10V/±50% o o o o 14 : Universal Ai (U-AI) ±10V/±4000 (h) o o o o 15 : PID feedback (PID-FB) ±10V/±20000 (d) o o o o 16 : PID reference value (PID-REF) ±10V/±20000 (d) o o o o 17 : PID correction gain (PID-G) ±10V/±4000 (h) o o o o 18 : Option Ai (O-AI) ±10V/±7FFF (h) o o o o e50 132h Ai2 function selection 0 to 18 (Refer to Ai1 function selection.) 59 o o o o o o o o e51 133h Ai3 function selection 0 to 18 (Refer to Ai1 function selection.) (Displayed when the AIO option is installed.) e52 134h Ai4 function selection 0 to 18 (Refer to Ai1 function selection.) (Displayed when the AIO option is installed.) Type Copy Save all Initialization Lifting machine 59 o o o o o o o x 59 o o o o o o o x Underline indicates a factory setting.

13. Function Code List<br />

Communication<br />

Control type: Available/<br />

address<br />

Not available<br />

Fcode<br />

485 Link<br />

number number<br />

Function name Function directory name<br />

Setting range<br />

PG LES VF SM<br />

27 : Synchronization completion signal (SY-C) o x x x<br />

28 : Lifetime alarm (LIFE) o o o o<br />

29 : Under acceleration (U-ACC) o o o o<br />

30 : Under deceleration (U-DEC) o o o o<br />

31 : Inverter overload early warning (INV-OL) o o o o<br />

32 : Motor overheat early warning (M-OH) o o o o<br />

33 : Motor overload early warning (M-OL) o o o o<br />

34 : DB overload early warning (DB-OL) o o x o<br />

35 : Link transmission error (LK-ERR) o o o o<br />

36 : load adaptive control under limiting (ANL) o x x x<br />

37 : load adaptive control under calculation (ANC) o x x x<br />

38 : Analog torque bias hold (TBH) o o x o<br />

39 to 47 : Option DO1 to 9 (O-DO1 to O-DO9) o o o o<br />

e16 110h 86 h Y2 terminal function 0 to 2 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e17 111h 87 h Y3 terminal function 0 to 3 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e18 112h 88 h Y4 terminal function 0 to 4 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e19 113h 89 h Y5 terminal function 0 to 14 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e20 114h 8A h Y11 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e21 115h 8B h Y12 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e22 116h 8C h Y13 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e23 117h 8D h Y14 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e24 118h 8E h Y15 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e25 119h 8F h Y16 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e26 11Ah 90 h Y17 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e27 11Bh 91 h Y18 terminal function 0 to 26 to 47 (Refer to Y1 function selection.) 58 o o o o o o o o<br />

e28 11Ch Y terminal function<br />

0000 to 001F<br />

36 o o o o o o o o<br />

normally open/close<br />

Setting of normal state of Y1to Y4,RY.<br />

0 : Normally open<br />

1 : Normally close<br />

e29 11Dh 92 h PG pulse output<br />

selection<br />

e30 11Eh Motor OH protection Motor OH protection<br />

(temperature)<br />

e31 11Fh M-OH early warning<br />

(temperature)<br />

e32 120h CD h M1-M3 (operation level<br />

PTC)<br />

You can change the setting of a function indicated by during operation.<br />

You should stop operation to change the setting of other functions.<br />

0 to 9<br />

0 : No dividing<br />

1 : 1/2<br />

2 : 1/4<br />

3 : 1/8<br />

4 : 1/16<br />

5 : 1/32<br />

6 : 1/64<br />

0 to 6 : Internal PG inputs are output after being<br />

divided.<br />

7 : Pulse oscillation mode (A/B 90° phase<br />

difference signal)<br />

Internal speed reference is output after pulse<br />

conversion.<br />

8 : PG (PD)<br />

Pulse inputs for position encoder are directly<br />

output.<br />

9 : PG (PR)<br />

Pulse inputs for position command are directly<br />

output.<br />

100 to 150 to 200 ℃<br />

It is effective when NTC thermistor is used with<br />

selected motor (M1,M2).<br />

50 to 75 to 200 ℃<br />

It is effective when NTC thermistor is used with<br />

selected motor (M1,M2).<br />

13-9<br />

92 o o o o x x o o<br />

0 o o o o o o o o<br />

0 o o o o o o o o<br />

0.00 to 1.60 to 5.00 V 3 o o o o o o o o<br />

e33 121h INV-OL early warning 25 to 90 to 100 % 0 o o o o o o o o<br />

e34 122h M-OL early warning 25 to 90 to 100 % 0 o o o o o o o o<br />

e35 123h DB overload protection 0 to 10 to 100 % 0 o o o o o x o o<br />

e36 124h DB-OL early warning 0 to 80 to 100 % 0 o o o o o x o o<br />

e37 125h DB thermal time constant 0 to 100 to 1000 s 0 o o o o o x o o<br />

Type<br />

Copy<br />

Save all<br />

Initialization<br />

Lifting<br />

machine<br />

Underline indicates a factory setting.