Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Communication<br />
Control type: Available/<br />
address<br />
Not available<br />
Fcode<br />
485 Link<br />
number number<br />
Function name Function directory name<br />
Setting range<br />
PG LES VF SM<br />
51 : Ai torque bias hold [H-TB] o o x o<br />
52 : STOP1 (The motor stops with normal<br />
deceleration time.) (STOP1)<br />
o o o o<br />
53 : STOP2 (The motor stops with deceleratime 4)<br />
(STOP2)<br />
54 : STOP3 (The motor stops with max, torque.)<br />
(STOP3)<br />
13-8<br />
o o o o<br />
o o o o<br />
55 : DIA data latch (DIA option) (DIA) o o o o<br />
56 : DIB data latch (DIB option) (DIB) o o o o<br />
57 : Mulitiwinding motor cancel (SI (MWS) option)<br />
(MT-CCL)<br />
o x x x<br />
58 to 63 : Option Di 1/2/3/4/5/6 (O-DI1 to 6) o o o o<br />
e02 102h 79 h X2 terminal function 0 to 1 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e03 103h 7A h X3 terminal function 0 to 2 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e04 104h 7B h X4 terminal function 0 to 3 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e05 105h 7C h X5 terminal function 0 to 4 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e06 106h 7D h X6 terminal function 0 to 5 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e07 107h 7E h X7 terminal function 0 to 7 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e08 108h 7F h X8 terminal function 0 to 8 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e09 109h 80 h X9 terminal function 0 to 9 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e10 10Ah 81 h X11 terminal function 0 to 25 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e11 10Bh 82 h X12 terminal function 0 to 25 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e12 10Ch 83 h X13 terminal function 0 to 25 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e13 10Dh 84 h X14 terminal function 0 to 25 to 63 (Refer to X1 function selection.) 57 o o o o o o o o<br />
e14 10Eh X terminal function<br />
normal open/close<br />
0000 to 01FF<br />
Setting of normal state of X1-X9.<br />
0 : Normal open<br />
1 : Normally closed<br />
35 o o o o o o o o<br />
e15 10Fh 85 h Y1 terminal function Y1 terminal function 0 to 1 to 47 58 o o o o o o o o<br />
You can change the setting of a function indicated by during operation.<br />
You should stop operation to change the setting of other functions.<br />
0 : Inverter running (RUN) o o o o<br />
1 : Speed existence signal (N-EX) o o o o<br />
2 : Speed agreement signal (N-AG) o o x o<br />
3 : Speed egilivarent signal (N-AR) o o x o<br />
4 : Speed level detection 1 (N-DT1) o o o o<br />
5 : Speed level detection 2 (N-DT2) o o o o<br />
6 : Speed level detection 3 (N-DT3) o o o o<br />
7 : Stopping on undervoltage (LU) o o o o<br />
8 : Detected torque polarity (Braking/Driving) (B/D) o o x o<br />
9 : Torque limiting (TL) o o x o<br />
10 : Torque detection 1 (T-DT1) o o o o<br />
11 : Torque detection 2 (T-DT2) o o o o<br />
12 : KEYPAD operation mode (KP) o o o o<br />
13 : Inverter stopping (STP) o o o o<br />
14 : Operation ready output (RDY) o o o o<br />
15 : Magnetic flux detection signal (MF-DT) o o x x<br />
16 : Motor M2 selection status (SW-M2) o o o o<br />
17 : Motor M3 selection status (SW-M3) o o o o<br />
18 : Mechanical brake release signal (BRK) o o x o<br />
19 : Alarm indication signal 1 (AL1) o o o o<br />
20 : Alarm indication signal 2 (AL2) o o o o<br />
21 : Alarm indication signal 4 (AL4) o o o o<br />
22 : Alarm indication signal 8 (AL8) o o o o<br />
23 : Fan operation signal (FAN) o o o o<br />
24 : Auto-resetting (TRY) o o o o<br />
25 : Universal DO (U-DO) o o o o<br />
26 : Heat sink overheat early warning (INV-OH) o o o o<br />
Type<br />
Copy<br />
Save all<br />
Initialization<br />
Lifting<br />
machine<br />
Underline indicates a factory setting.