13. Function Code List 13.1 Function Code Configuration 13.1.1 Identification Code Displayed on KEYPAD Panel F 0 0 Code number Identification code Function code Function Notes Fundamental functions F00 to F80 Fundamental function Displayed on KEYPAD panel always Extensional terminal E01 to E84 Terminal function Some codes are displayed only when functions options are installed E51, 52 Function codes for OPC-VG7-AIO option E55, 56 Function codes for OPC-VG7-AIO option E59, 60 Function codes for OPC-VG7-AIO option E63, 64 Function codes for OPC-VG7-AIO option E67, 68 Function codes for OPC-VG7-AIO option E72, 73 Function codes for OPC-VG7-AIO option E77, 78 Function codes for OPC-VG7-AIO option E82, 83 Function codes for OPC-VG7-AIO option Control functions of frequency C01 to C73 Control function Displayed on KEYPAD panel always Motor Parameters P01 to P30 Motor parameter function for M1 High performance functions H01 to H73 High performance function Alternative motor parameters A01 to A50 Motor parameters for M2 and M3 Optional functions o01 to o41 Option function Displayed when options are installed. PG (PR) option codes are displayed always. o01 to o04 Function codes for OPC-VG7-DIA and DIB options o05 Function codes for OPC-VG7-PG (PD) option o06 to o08 Function codes for OPC-VG7-PG (LD) digital line speed detection option o09 to o11 Function codes for OPC-VG7-PMPG synchronous motor PG option o12 to o19 Function codes for OPC-VG7-PG (PR) pulse train input option o30 to o32 Function codes for OPC-VG7-TL field bus option o33, o34 Function code for OPC-VG7-SI (MWS) multi-winding system option o35 to o36 Function codes for OPC-VG7-SI (UPAC) option o37 Function code for OPC-VG7-RS option o38 to o41 Function codes for OPC-VG7-UPAC option Lift functions L01 to L15 Lift functions User functions U01 to U64 User functions You can use for UPAC option. (UPAC) Displayed on KEYPAD panel always. Serial communication S01 to S12 Command functions You cannot refer to or change in LOC mode functions (KEYPAD panel). Monitoring functions M01 to Data monitor You can use in COM mode (T-Link, RS-485, M60 functions SI, SX, and field bus) and UPAC. 13-1

13.2 Function Code List 13.2.1 Function Code List Description Item Description Fcode Identification codes for function codes. Communication Address used with integrated RS-485 or UPAC option (OPC-VG7-UPAC) to refer to or address 485 number change function codes. Communication Address used with field bus options (OPC-VG7-TL, OPC-VG7-SX and field bus options) address to refer to or change function codes. You cannot use a filed bus option for a function Link number code without a communication address Link number. Function code name Function directory name Name assigned to a group of function codes with a similar nature. Name of an individual function of a function code. Setting range Indicates the setting range and the data definition. Factory setting Data specified by FUJI before delivery. Modified data are displayed with ∗ (asterisk) on the KEYPAD panel. You can use the initialization function code to reset them to the factory setting. Type Indicates a format type used to refer to or change data through communication system (such as RS-485 and filed bus). See 13.3 “Function Code List Dedicated for Communication” for more information. Copy Save all Initialization Control type: Available/ Not available Lifting machine 13.2.2 List F: Fundamental Functions Indicates whether to be copied or not to another inverter when you use the copy function of the KEYPAD panel to copy entire data stored in the KEYPAD panel. Indicates the function code saved with H02 “save all function” (writing the non-volatile memory). �: Saved function. ×: Function not saved. Indicates whether to be initialized (reset to the factory setting) or not by the function code H03 “Data initializing”. �: Initialized, ×: Not initialized. Indicates whether available or not in individual control types (PG: Vector control with PG, LES: Sensorless vector control, VF: V/f control, SM: Vector control to drive synchronous motor). Indicates the parameter displayed on the keypad panel if H70 is set at “1 (lifting machine).” �: displayed, ×: Not displayed Communication Control type: Available/ address Fcode 485 Link number number Function code name Function directory name Setting range Not available PG LES VF SM f00 0h 50 h Data protection 0 to 1 “*” is displayed on the keypad panel. 0 : Data change enable 1 : Data protection This is a function to protect writing from the Keypad panel. The protection of writing from the link (T-Link, RS485, etc.) is defined with H29 "Link function protection". 40 x o o o o o o o f01 1h Speed setting N1 0 to 7 0 : KEYPAD operation ( ∧ and ∨ key) 1 : Analog input (0 to ±10VDC) 2 : Analog input (0 to +10VDC) 3 : UP/DOWN control 1 (initial speed = 0 r/min) 4 : UP/DOWN control 2 (initial speed = last value) 5 : UP/DOWN control 3 (initial speed = Creep speed 1 or 2) 6 : DIA card input 7 : DIB card input You can change the setting of a function indicated by during operation. You should stop operation to change the setting of other functions. 13-2 Type Copy Save all Initialization Lifting machine 41 o o o o o o o o Underline indicates a factory setting.

13.2 Function Code List<br />

13.2.1 Function Code List Description<br />

Item Description<br />

Fcode Identification codes for function codes.<br />

Communication Address used with integrated RS-485 or UPAC option (OPC-VG7-UPAC) to refer to or<br />

address<br />

485 number<br />

change function codes.<br />

Communication Address used with field bus options (OPC-VG7-TL, OPC-VG7-SX and field bus options)<br />

address<br />

to refer to or change function codes. You cannot use a filed bus option for a function<br />

Link number code without a communication address Link number.<br />

Function code<br />

name<br />

Function directory<br />

name<br />

Name assigned to a group of function codes with a similar nature.<br />

Name of an individual function of a function code.<br />

Setting range Indicates the setting range and the data definition.<br />

Factory setting Data specified by FUJI before delivery. Modified data are displayed with ∗ (asterisk) on<br />

the KEYPAD panel. You can use the initialization function code to reset them to the<br />

factory setting.<br />

Type<br />

Indicates a format type used to refer to or change data through communication system<br />

(such as RS-485 and filed bus).<br />

See 13.3 “Function Code List Dedicated for Communication” for more information.<br />

Copy<br />

Save all<br />

Initialization<br />

Control type:<br />

Available/ Not<br />

available<br />

Lifting machine<br />

13.2.2 List<br />

F: Fundamental Functions<br />

Indicates whether to be copied or not to another inverter when you use the copy function<br />

of the KEYPAD panel to copy entire data stored in the KEYPAD panel.<br />

Indicates the function code saved with H02 “save all function” (writing the non-volatile<br />

memory). �: Saved function. ×: Function not saved.<br />

Indicates whether to be initialized (reset to the factory setting) or not by the function code<br />

H03 “Data initializing”. �: Initialized, ×: Not initialized.<br />

Indicates whether available or not in individual control types (PG: Vector control with PG,<br />

LES: Sensorless vector control, VF: V/f control, SM: Vector control to drive synchronous<br />

motor).<br />

Indicates the parameter displayed on the keypad panel if H70 is set at “1 (lifting<br />

machine).” �: displayed, ×: Not displayed<br />

Communication<br />

Control type: Available/<br />

address<br />

Fcode<br />

485 Link<br />

number number<br />

Function code<br />

name<br />

Function directory name<br />

Setting range<br />

Not available<br />

PG LES VF SM<br />

f00 0h 50 h Data protection 0 to 1 “*” is displayed on the keypad panel.<br />

0 : Data change enable<br />

1 : Data protection<br />

This is a function to protect writing from the Keypad<br />

panel.<br />

The protection of writing from the link (T-Link,<br />

RS485, etc.) is defined with H29 "Link function<br />

protection".<br />

40 x o o o o o o o<br />

f01 1h Speed setting N1 0 to 7<br />

0 : KEYPAD operation ( ∧ and ∨ key)<br />

1 : Analog input (0 to ±10VDC)<br />

2 : Analog input (0 to +10VDC)<br />

3 : UP/DOWN control 1 (initial speed = 0 r/min)<br />

4 : UP/DOWN control 2 (initial speed = last value)<br />

5 : UP/DOWN control 3 (initial speed = Creep<br />

speed 1 or 2)<br />

6 : DIA card input<br />

7 : DIB card input<br />

You can change the setting of a function indicated by during operation.<br />

You should stop operation to change the setting of other functions.<br />

13-2<br />

Type<br />

Copy<br />

Save all<br />

Initialization<br />

Lifting<br />

machine<br />

41 o o o o o o o o<br />

Underline indicates a factory setting.