Additional Requirements:<br />
‣ A list of 35 or more mobile pump testing unit users must be provided as per the <strong>Draft</strong><br />
<strong>Commander</strong> <strong>3000®</strong> A/T <strong>Mobile</strong> <strong>Fire</strong> <strong>Pump</strong> Testing & Training Simulator Specifications.<br />
‣ Operation and Training Manual, along with a video, will be provided upon delivery of<br />
the mobile pump testing unit.<br />
‣ The mobile pump testing and training simulator has been in service and field tested for<br />
over ten (10) years.<br />
‣ Descriptive information such as literature/brochures of these specifications to be<br />
furnished with bid.<br />
‣ Hands on personnel training and operations to be included.<br />
Optional Packages<br />
Option 1 Package Needed To Perform <strong>Pump</strong> Testing Simultaneously On Two <strong>Fire</strong> Apparatus:<br />
‣ Two (2) 50 ft sections of 3” double jacket 600# test fire hose coupled with 2 ½” couplings<br />
with NST threads.<br />
‣ One (1) <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong> <strong>Mobile</strong> <strong>Fire</strong> <strong>Pump</strong> Testing & Training Simulator<br />
Monitor Station, model number DC1911-3000, or One (1) Mini <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong><br />
<strong>Mobile</strong> <strong>Fire</strong> <strong>Pump</strong> Testing & Training Simulator Monitor Station, model number<br />
MW1911-3000.<br />
Option 2 Package Needed To Perform <strong>Pump</strong> Testing On A 3000 – 4000 GPM <strong>Fire</strong> Apparatus:<br />
‣ Portable 6” drafting tube with 90˚ elbow equipped with 6” swivel female NST threads.<br />
The portable drafting tube can be premantaly mounted to the <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong><br />
or mounted on the <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong> transport and used only when needed.<br />
Optional <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong> A/T <strong>Mobile</strong> <strong>Fire</strong> <strong>Pump</strong> Testing & Training Simulator<br />
Equipment:<br />
‣ Aluminum Rims<br />
‣ Albert 2.99 X 8 TPI on all 2 ½” threads on manifolds. Special threads in place of<br />
standard NST threads on manifold adaptors and fire hose.<br />
‣ Custom wrap<br />
‣ Gauges on test monitor to be PSI/KPA in place of standard PSI<br />
Revised 7-2012<br />
Page 14