Revised 7-2012 3000 Gallons Capacity Draft Commander 3000® A/T Reservoir: ‣ Reservoir is manufactured of heavy duty poly throughout the Draft Commander 3000® A/T externally and internal which includes bottom, sides, top, and suction and discharge compartments. ‣ Reservoir is “T” shaped and attached to the transporter and mounted so it can not shift and will flex with the transporter. ‣ The drafting pit section of the reservoir to have four (4) anti-swirl plates and a water temperature gauge to monitor water temperature. ‣ The top and rear of the Draft Commander 3000® A/T reservoir to be painted with two (2) coats of white polyurethane, UV rated, to enhance the cooling system. ‣ The mobile drafting water reservoir to have a section which is an independent suction drafting pit in the reservoir, and receives water flow through a special designed integrated section of the reservoir that removes cavitations/disturbance and air from the water so when water is entering the reservoir from high volume and pressure of water being pumped out of the drafting pit section from the apparatus being tested. Thus when the water reaches the draft pit section it will maintain the correct water depth preventing water disturbance and air swirls causing the apparatus to loose prime. ‣ The right and left of the Draft Commander 3000® A/T to be laminated oraject 3951 RA 2-mil gloss white injet vinyl UV rated premium cast PIC gloss cold over laminate highest level of conformability which offers superior level of UV protection. Pointed in the laminate is the Draft Commander 3000® A/T logo and manufacturing identification number. Note: Lettering and logos of municipalities or service agencies can be added upon request and can be added to each side. ‣ Ventilators located at the front and rear center of the Draft Commander 3000® A/T reservoir 27” long x 14” wide x 17” high and manufactured of .125 aluminum tread plate. ‣ The ventilators are to be equipped with full length aluminum tread plate doors equipped with stainless steel hinges and devices to hold doors open for ventilation. ‣ Ventilator doors to be equipped with a close fastener for when transporting. ‣ Integrated water cooling system to help maintain a stable water temperature with two (2) 2 ½” inlets and one (1) 4” discharge in order to discharge warm water from reservoir. ‣ The 4” discharge is discharged at front right side of reservoir and controlled with quarter turn ball valve 2 ½” NST male and capped. ‣ All internal anti-water flow cavitation compartment sections to be made of ½” or larger heavy duty poly and supported and welded to withstand large volumes of water that flow to the suction drafting pit compartment. ‣ Reservoir clean out sump drain equipped with 2½” drain and controlled with a 2½” quarter turn valve and to discharge at right rear of transporter. ‣ Located at the front of the test reservoir are two (2) aluminum 1/8” tread plate stone shield (14” wide by 30¾” long) one (1) located on the right, and one (1) located on the left side. ‣ The mobile fire pump testing and training simulator is designed to test fire pumps up to Page 10

3,000 GPM plus. ‣ One (1) liquid site water gauge installed at rear of reservoir drafting pit and one (1) at front of discharge receiving area. ‣ Lifetime warranty on tank reservoir. Drafting Tubes: ‣ Two (2) 6” drafting tubes located in draft pit section of draft commander reservoir and equipped with special designed aluminum powder coated heavy duty 45° 6” 360° elbow swivels. Note: Swivel and dry hydrant elbows manufactured of PVC will not be accepted. ‣ The swivels are designed so you can position the apparatus at the rear, left, or right side. ‣ Swivels are equipped with a grease zerk to lubricate swivels. Special Designed 45° Heavy Duty Powered Coated Drafting Swivels: ‣ On top of 360° elbow swivels a suction vacuum breaker to be installed and to be controlled at the rear of the transporter on each elbow. Hard Suction Hose: ‣ Two (2) 17 ft of 6” flexible hard suction hose preconnected to the drafting tubes and stored on top of the Draft Commander 3000®. One end attached to the 360° elbow swivel and the other end equipped with 6” long handle swivel NFT female. ‣ Two (2) hard suction trays to have hold down straps to secure the hard suction hose. ‣ The trays to be made of 1/8” aluminum plate 46” length by 8 ½” wide by 4 ½” depth. ‣ Hard suction hose is clear which allows greater visibility of the water and making sure there is no air in the suction tubes. ‣ Hard suction hose supports are installed from the left pitot gauge compartment area and wrap around the rear of the Draft Commander 3000® reservoir to the right side pitot gauge compartment area. The hose support is 15” in height and is manufactured of 1 ¼” aluminum tubular. This is to support the hard suction hose when fire pump testing from the right, left, and rear of the transporter. Extra Hard Suction Trays: ‣ Two (2) 10 ft. of 6” flexible hard suction hose. The hose is clear which allows greater visibility of the water. ‣ Couplings on the hard suction hose: one (1) 6” swivel female L.H. N.S.T. thread at one end and (1) 6” male L.H. N.S.T. threads on the other end. ‣ The hard suction hoses shall be stored one on each side of the tank between the fender wells and the tank body. Revised 7-2012 Mobile Pump Testing& Training Simulator Equipped With: ‣ Equipped with a hand held monitor that monitors the following: Air Temperature, Atmospheric Pressure, and Altimeter. ‣ One (1) 3” water temperature gauge showing 0 – 200 degrees installed in the suction Page 11

3,000 GPM plus.<br />

‣ One (1) liquid site water gauge installed at rear of reservoir drafting pit and one (1) at<br />

front of discharge receiving area.<br />

‣ Lifetime warranty on tank reservoir.<br />

<strong>Draft</strong>ing Tubes:<br />

‣ Two (2) 6” drafting tubes located in draft pit section of draft commander reservoir and<br />

equipped with special designed aluminum powder coated heavy duty 45° 6” 360° elbow<br />

swivels. Note: Swivel and dry hydrant elbows manufactured of PVC will not be accepted.<br />

‣ The swivels are designed so you can position the apparatus at the rear, left, or right side.<br />

‣ Swivels are equipped with a grease zerk to lubricate swivels.<br />

Special Designed 45° Heavy Duty Powered Coated <strong>Draft</strong>ing Swivels:<br />

‣ On top of 360° elbow swivels a suction vacuum breaker to be installed and to be<br />

controlled at the rear of the transporter on each elbow.<br />

Hard Suction Hose:<br />

‣ Two (2) 17 ft of 6” flexible hard suction hose preconnected to the drafting tubes and<br />

stored on top of the <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong>. One end attached to the 360° elbow swivel<br />

and the other end equipped with 6” long handle swivel NFT female.<br />

‣ Two (2) hard suction trays to have hold down straps to secure the hard suction hose.<br />

‣ The trays to be made of 1/8” aluminum plate 46” length by 8 ½” wide by 4 ½” depth.<br />

‣ Hard suction hose is clear which allows greater visibility of the water and making sure<br />

there is no air in the suction tubes.<br />

‣ Hard suction hose supports are installed from the left pitot gauge compartment area and<br />

wrap around the rear of the <strong>Draft</strong> <strong>Commander</strong> <strong>3000®</strong> reservoir to the right side pitot<br />

gauge compartment area. The hose support is 15” in height and is manufactured of 1 ¼”<br />

aluminum tubular. This is to support the hard suction hose when fire pump testing from<br />

the right, left, and rear of the transporter.<br />

Extra Hard Suction Trays:<br />

‣ Two (2) 10 ft. of 6” flexible hard suction hose. The hose is clear which allows greater<br />

visibility of the water.<br />

‣ Couplings on the hard suction hose: one (1) 6” swivel female L.H. N.S.T. thread at one<br />

end and (1) 6” male L.H. N.S.T. threads on the other end.<br />

‣ The hard suction hoses shall be stored one on each side of the tank between the fender<br />

wells and the tank body.<br />

Revised 7-2012<br />

<strong>Mobile</strong> <strong>Pump</strong> Testing& Training Simulator Equipped With:<br />

‣ Equipped with a hand held monitor that monitors the following: Air Temperature,<br />

Atmospheric Pressure, and Altimeter.<br />

‣ One (1) 3” water temperature gauge showing 0 – 200 degrees installed in the suction<br />