<strong>EM</strong>G-4754<br />

<strong>EM</strong>G -4755<br />

<strong>EM</strong>G -4756 8-, 12·, 16-channel Electro Encephalographs<br />

•<br />

When performing electrophysiological examinations in neuropathology<br />

and psychiatry, the equipments can be used for scien·<br />

tific analysis as well as diagnostics. The equipments meet all<br />

requirements made with up-to-date encephalographs. Owing to<br />

their high sensit ivity (1 mmf!J.V), low own noise, high immunity<br />

for external disturbing signals, high number of channels and<br />

other special provisions t he equipments can be used for scientific<br />

research in addition to the routine tests. The preamplifiers and<br />

the recorder are designed a.s separate units. The type <strong>EM</strong>G-4754<br />

has 8, the t ype <strong>EM</strong> G-4755 has 12. the type <strong>EM</strong>G -4756 has 16<br />

channels. The construction of the equipments and arrangement<br />

of their units ensure that the operator can sit comfortably.<br />

The preamplifier channels, the common amplification control.<br />

the routine switch and the calibrating unit are designed as plug-in<br />

units. Besides the recorders of the EEG lead the instrument<br />

is provided also with two separate recorders used for recording<br />

the time signals in every second, marker signals as well as for<br />

recording stimulating signals in case of stimulation.<br />

By means of the selector switches, the electrode points and the<br />

indifferent point can be coupled to the input of amplifier channels<br />

in any combination. The plug-in routine switches serve for the<br />

adjustment of 9 routine programs. For separate order, <strong>EM</strong>G<br />

supplies routine switches allowing of t he adjustment of other<br />

r equired programs. Two polygraph amplifier s with 1 mY sensitivity<br />

are built into the main recorder unit , and can be switched<br />

instead of the two last channels. They ar e suitable for the exa·<br />

mination of the var ious physiological functions, intercon necting<br />

the appropriate transducers. There is also a possibility for connection<br />

to an oscilloscope. The photostimulators types <strong>EM</strong>G-4761<br />

and <strong>EM</strong>G -4764 or phonostimulators types <strong>EM</strong>G -4762 and <strong>EM</strong> G-<br />

4763 can also be connected to the equipment.<br />

STIMULATORS<br />

Photo- and phonostimulators ar e an applience for· performing<br />

electrophysiological examinations in neurology, and psychiatry.<br />

Their special field of a pplication is electro encephalography. The<br />

instruments are fully transistorized.<br />

<strong>EM</strong>G -4761 Photostimulator<br />

It is suitable for produci ng light stimuli with adjustable flas h<br />

frequencies. Both the intensity and the colour of the light<br />

stimuli can be altered. The frequency can be adjusted between<br />

2 and SO cfs.<br />

<strong>EM</strong>G-4762 Phonostimulator<br />

The instrument is capable of producing continuous sound signals<br />

with 5 different frequencies for sound stimuli. Intensity of the<br />

ow d istortion signals can be adjusted.