ELECTRO ENCEPHALOGRAPHS<br />
<strong>EM</strong>G-4751 Eight-channel Electro Encephalograph<br />
When performing electrophysiological examinations in neuro.<br />
pathology and psychiatry, the equipment can be used for scientific<br />
analysis as well as diagnostics. It serves for examination of the<br />
bioelectric potentials of the cervix of the human brain and can<br />
record the test data. It is an up-to-date design, easy to operate<br />
equipment. 25 electrode points and 3 earthing points can be<br />
connected to the equipment. By means of the selector switches,<br />
any combination of the electrodes can be coupled to the inputs<br />
of the 8 amplifier channels. The instrument is also provided<br />
with interchangeable plug-in routine switches. Each routine<br />
switch allows of the selection of 9 routine programs. The amplifier<br />
channels are made as plug-in units. Max. sensitivity of the<br />
channels is 1 mmff!.V. The built-in resistance meter serves for<br />
measurement of the resistances of the electrodes. The built-in<br />
calibrating unit facilitates recording of the cal ibrating voltage<br />
changes. Recording is made with an inkwriting recorders on<br />
paper charts.<br />
Dimensions:<br />
1175x1140 x780 mm<br />
<strong>EM</strong>G-4752 Four-channel Electro Encephalograph<br />
As the instrument is of a portable design, it can be used for the<br />
examination of patients who, for any reason, cannot oe transferred<br />
to the EEG laboratory. Just like instruments provided with<br />
more channels, there are connection facilities for 25 electrode<br />
and 3 earthing points on the instrument. By means of the selector<br />
switches, any combination of the electrodes can be coupled to<br />
the inputs of the four amplifier channels. The built-in routine<br />
switch allows of the selection of 9 routine programs. By means<br />
of a built-in resistance meter, electrode resistances can be<br />
measured, while the internal calibrating signal can be used for<br />
recording calibration voltage changes. Recording is made with<br />
inkwriting recorders on paper charts.<br />
Dimensions:<br />
260 x 61 S X 430 mm<br />
<strong>EM</strong>G-4753 Four-channel Electro Nystagmograph<br />
The equipment serves for the amplification and recording of<br />
spontaneous and brought-about nystagmus. 8 electrodes and<br />
2 earthing electrodes can be connected to the portable, up-todate<br />
design instrument. Resistances of the electrodes can be<br />
measured by means of a built-in resistance meter. Signals amplified<br />
to an appropriate level are recorded by inkwriting recorders.<br />
Dimensions:<br />
260x625x430 mm