ORION EM G
ORION EM G
ORION EM G
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>EM</strong>G-1851 T R-9150<br />
<strong>EM</strong>G -1853 TR-9151<br />
<strong>EM</strong>G - 1856 TR-915-4<br />
<strong>EM</strong>G-1857 TR-9155 Transistorized Power Supplies<br />
They are fully transistorized DC Power Supplies. The types <strong>EM</strong>G-1852 and <strong>EM</strong>G-1856<br />
contain two independent units, which can be used independently of each other, In<br />
series and also In parallel operation. The output current is checked by a built-in indicating<br />
meter. The instruments are provided with overcurrent protection.<br />
~o~, ,<br />
I<br />
...<br />
-·-<br />
•<br />
_<br />
.. ~..... - r~<br />
0·-\,7<br />
-;-: a· ·.~<br />
..·<br />
- ~ i<br />
@ ~· : r ··<br />
·.~· ·.~·<br />
~~~<br />
; -~- -::=-_ -~- •<br />
<strong>EM</strong>G-1852 <strong>EM</strong>G-1853<br />
Output voltage TR-9150 TR-9151<br />
and max. output current: 2 x 0to30 V; 1.5A Oto30V;<br />
orO to 60 V ; 1.5 A 1.5 A<br />
or 0 to 30 V; 3 A<br />
Output voltage regulation : in decadic steps of 10; 1; 0.1 Y<br />
Accuracy of output voltage:<br />
Stability<br />
±2% ±20 mY<br />
> 500 : 1<br />
(at ± 10% mains fluctuation) : 270x210x370 mm<br />
Dimensions:<br />
l..O x 180 x 250 mm<br />
<strong>EM</strong>G-1855 <strong>EM</strong>G-1856<br />
TR-915-4 TR-9155<br />
l x O to 100 V; 0.5 A<br />
0 to 100 V; 0.5 A<br />
or 0 to 200 V; 0.5 A<br />
or 0 tO 100 V; 0.8 A<br />
in decadic steps of 10.<br />
1 V and continuously 0 to 1 V<br />
±2%<br />
> 500 : 1<br />
270 x 210 x 370 mm<br />
HO x 180 x 250 mm<br />
<strong>EM</strong> G-1858 TR-9156 Laboratory Constant Voltaae1Constant<br />
Current Power Supply<br />
The high-stability power supply can be operated in t he 0 to 30 V<br />
and 0 to 10 A ranges, both in the constant voltage and the constant<br />
current modes of ope ration. Output voltage and current can be<br />
checked by means of a bu ilt-in indicatinc meter. The power<br />
supply is provided with overload protection.<br />
CONSTANT -VOLTAGE MODE 0 F OPERATION<br />
Output voltage:<br />
Output voltage regulation:<br />
Accuracy of output voltage:<br />
Rated loading range:<br />
Stability<br />
(at ± 10% mains fluctuation) :<br />
CONSTANT-CURRENT MODE OF OPERATION<br />
Output current;<br />
Output current regulation :<br />
Accuracy of output current:<br />
Output voltage range:<br />
Stability<br />
(at ± 10% mains fluctuation):<br />
Dimensions :<br />
0 to 30 Y<br />
in decadic steps of<br />
10; 1; 0.1 Y and<br />
continuously<br />
±100 mY<br />
±2%±3 mY<br />
0 to 10 A<br />
> 5000 : 1 or ±1 mY<br />
0 to 10 A<br />
in de cad ic steps of 1:<br />
0.1 A<br />
±2%±3 rnA<br />
0 to 35 V<br />
> 2500 : 1 or ±2 rnA<br />
220x380x HO mm<br />
___ ,<br />
...<br />
,.._.,. _____ _